REGULATIONS
Vol. 33 Iss. 4 - October 17, 2016

TITLE 9. ENVIRONMENT
STATE AIR POLLUTION CONTROL BOARD
Chapter 40
Final Regulation

REGISTRAR'S NOTICE: The following regulatory action is exempt from Article 2 of the Administrative Process Act in accordance with § 2.2-4006 A 4 c of the Code of Virginia, which excludes regulations that are necessary to meet the requirements of federal law or regulations, provided such regulations do not differ materially from those required by federal law or regulation. The State Air Pollution Control Board will receive, consider, and respond to petitions by any interested person at any time with respect to reconsideration or revision.

Titles of Regulations: 9VAC5-20. General Provisions (Rev. F16) (amending 9VAC5-20-21).

9VAC5-40. Existing Stationary Sources (Rev. F16) (amending 9VAC5-40-6250, 9VAC5-40-6440, 9VAC5-40-6520).

Statutory Authority: § 10.1-1308 of the Code of Virginia; §§ 110, 111, 123, 129, 171, 172, and 182 of the Clean Air Act; 40 CFR Parts 51 and 60.

Effective Date: November 16, 2016.

Agency Contact: Karen G. Sabasteanski, Department of Environmental Quality, 629 East Main Street, P.O. Box 1105, Richmond, VA 23218, telephone (804) 698-4426, FAX (804) 698-4510, or email karen.sabasteanski@deq.virginia.gov.

Summary:

On June 23, 2016 (81 FR 40956), the U.S. Environmental Protection Agency (EPA) amended the emissions guidelines for commercial/industrial/solid waste incinerators at Subpart DDDD of 40 CFR Part 60. The amendments were made to (i) revise the definitions of "continuous emission monitoring system data during startup and shutdown periods" and "kiln," (ii) revise the particulate matter limit for the waste-burning kiln subcategory, (iii) revise the fuel variability factor for coal-burning energy recovery units, and (iv) remove the provisions for affirmative defense. Virginia implements Subpart DDDD in Article 45 (9VAC5-40-6250 et seq.) of 9VAC5-40, Existing Stationary Sources. Although the provisions of Subpart DDDD are adopted by reference into Article 45, some revisions to Article 45 are necessary for the regulation to accurately track the EPA revisions.

9VAC5-20-21. Documents incorporated by reference.

A. The Administrative Process Act and Virginia Register Act provide that state regulations may incorporate documents by reference. Throughout these regulations, documents of the types specified below have been incorporated by reference.

1. United States Code.

2. Code of Virginia.

3. Code of Federal Regulations.

4. Federal Register.

5. Technical and scientific reference documents.

Additional information on key federal regulations and nonstatutory documents incorporated by reference and their availability may be found in subsection E of this section.

B. Any reference in these regulations to any provision of the Code of Federal Regulations (CFR) shall be considered as the adoption by reference of that provision. The specific version of the provision adopted by reference shall be that contained in the CFR (2014) (2016) in effect July 1, 2014 2016. In making reference to the Code of Federal Regulations, 40 CFR Part 35 means Part 35 of Title 40 of the Code of Federal Regulations; 40 CFR 35.20 means § 35.20 in Part 35 of Title 40 of the Code of Federal Regulations.

C. Failure to include in this section any document referenced in the regulations shall not invalidate the applicability of the referenced document.

D. Copies of materials incorporated by reference in this section may be examined by the public at the central office of the Department of Environmental Quality, Eighth Floor, 629 East Main Street, Richmond, Virginia, between 8:30 a.m. and 4:30 p.m. of each business day.

E. Information on federal regulations and nonstatutory documents incorporated by reference and their availability may be found below in this subsection.

1. Code of Federal Regulations.

a. The provisions specified below from the Code of Federal Regulations (CFR) are incorporated herein by reference.

(1) 40 CFR Part 50 -- National Primary and Secondary Ambient Air Quality Standards.

(a) Appendix A-1 -- Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide in the Atmosphere (Ultraviolet Fluorescence Method).

(b) Appendix A-2 -- Reference Method for the Determination of Sulfur Dioxide in the Atmosphere (Pararosaniline Method).

(c) Appendix B -- Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-Volume Method).

(d) Appendix C -- Measurement Principle and Calibration Procedure for the Continuous Measurement of Carbon Monoxide in the Atmosphere (Non-Dispersive Infrared Photometry).

(e) Appendix D -- Measurement Principle and Calibration Procedure for the Measurement of Ozone in the Atmosphere.

(f) Appendix E -- Reserved.

(g) Appendix F -- Measurement Principle and Calibration Procedure for the Measurement of Nitrogen Dioxide in the Atmosphere (Gas Phase Chemiluminescence).

(h) Appendix G -- Reference Method for the Determination of Lead in Suspended Particulate Matter Collected from Ambient Air.

(i) Appendix H -- Interpretation of the National Ambient Air Quality Standards for Ozone.

(j) Appendix I -- Interpretation of the 8-Hour Primary and Secondary National Ambient Air Quality Standards for Ozone.

(k) Appendix J -- Reference Method for the Determination of Particulate Matter as PM10 in the Atmosphere.

(l) Appendix K -- Interpretation of the National Ambient Air Quality Standards for Particulate Matter.

(m) Appendix L -- Reference Method for the Determination of Fine Particulate Matter as PM2.5 in the Atmosphere.

(n) Appendix M -- Reserved.

(o) Appendix N -- Interpretation of the National Ambient Air Quality Standards for PM2.5.

(p) Appendix O -- Reference Method for the Determination of Coarse Particulate Matter as PM in the Atmosphere.

(q) Appendix P -- Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone.

(r) Appendix Q -- Reference Method for the Determination of Lead in Suspended Particulate Matter as PM10 Collected from Ambient Air.

(s) Appendix R -- Interpretation of the National Ambient Air Quality Standards for Lead.

(t) Appendix S -- Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide).

(u) Appendix T -- Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Sulfur (Sulfur Dioxide).

(v) Appendix U -- Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone.

(2) 40 CFR Part 51 -- Requirements for Preparation, Adoption, and Submittal of Implementation Plans.

(a) Appendix M -- Recommended Test Methods for State Implementation Plans.

(b) Appendix S -- Emission Offset Interpretive Ruling.

(c) Appendix W -- Guideline on Air Quality Models (Revised).

(d) Appendix Y -- Guidelines for BART Determinations Under the Regional Haze Rule.

(3) 40 CFR Part 55 -- Outer Continental Shelf Air Regulations.

(4) 40 CFR Part 58 -- Ambient Air Quality Surveillance.

Appendix A -- Quality Assurance Requirements for SLAMS, SPMs and PSD Air Monitoring.

(5) 40 CFR Part 59 -- National Volatile Organic Compound Emission Standards for Consumer and Commercial Products.

(a) Subpart C -- National Volatile Organic Compound Emission Standards for Consumer Products.

(b) Subpart D -- National Volatile Organic Compound Emission Standards for Architectural Coatings, Appendix A -- Determination of Volatile Matter Content of Methacrylate Multicomponent Coatings Used as Traffic Marking Coatings.

(6) 40 CFR Part 60 -- Standards of Performance for New Stationary Sources.

The specific provisions of 40 CFR Part 60 incorporated by reference are found in Article 5 (9VAC5-50-400 et seq.) of Part II of 9VAC5-50 (New and Modified Stationary Sources).

(7) 40 CFR Part 61 -- National Emission Standards for Hazardous Air Pollutants.

The specific provisions of 40 CFR Part 61 incorporated by reference are found in Article 1 (9VAC5-60-60 et seq.) of Part II of 9VAC5-60 (Hazardous Air Pollutant Sources).

(8) 40 CFR Part 63 -- National Emission Standards for Hazardous Air Pollutants for Source Categories.

The specific provisions of 40 CFR Part 63 incorporated by reference are found in Article 2 (9VAC5-60-90 et seq.) of Part II of 9VAC5-60 (Hazardous Air Pollutant Sources).

(9) 40 CFR Part 64 -- Compliance Assurance Monitoring.

(10) 40 CFR Part 72 -- Permits Regulation.

(11) 40 CFR Part 73 -- Sulfur Dioxide Allowance System.

(12) 40 CFR Part 74 -- Sulfur Dioxide Opt-Ins.

(13) 40 CFR Part 75 -- Continuous Emission Monitoring.

(14) 40 CFR Part 76 -- Acid Rain Nitrogen Oxides Emission Reduction Program.

(15) 40 CFR Part 77 -- Excess Emissions.

(16) 40 CFR Part 78 -- Appeal Procedures for Acid Rain Program.

(17) 40 CFR Part 152 Subpart I -- Classification of Pesticides.

(18) 49 CFR Part 172 -- Hazardous Materials Table. Special Provisions, Hazardous Materials Communications, Emergency Response Information, and Training Requirements, Subpart E, Labeling.

(19) 29 CFR Part 1926 Subpart F -- Fire Protection and Prevention.

b. Copies may be obtained from Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954; telephone (202) 783-3238.

2. U.S. Environmental Protection Agency.

a. The following documents from the U.S. Environmental Protection Agency are incorporated herein by reference:

(1) Reich Test, Atmospheric Emissions from Sulfuric Acid Manufacturing Processes, Public Health Service Publication No. PB82250721, 1980.

(2) Compilation of Air Pollutant Emission Factors (AP-42). Volume I: Stationary and Area Sources, stock number 055-000-00500-1, 1995; Supplement A, stock number 055-000-00551-6, 1996; Supplement B, stock number 055-000-00565, 1997; Supplement C, stock number 055-000-00587-7, 1997; Supplement D, 1998; Supplement E, 1999.

(3) "Guidelines for Determining Capture Efficiency" (GD-35), Emissions Monitoring and Analysis Division, Office of Air Quality Planning and Standards, January 9, 1995.

b. Copies of the document identified in subdivision E 2 a (1) of this section, and Volume I and Supplements A through C of the document identified in subdivision E 2 a (2) of this section, may be obtained from U.S. Department of Commerce, National Technical Information Service, 5285 Port Royal Road, Springfield, VA 22161; telephone 1-800-553-6847. Copies of Supplements D and E of the document identified in subdivision E 2 a (2) of this section may be obtained online from EPA's Technology Transfer Network at http://www.epa.gov/ttn/index.html. Copies of the document identified in subdivision E 2 a (3) of this section are only available online from EPA's Technology Transfer Network at http://www.epa.gov/ttn/emc/guidlnd.html.

3. United States government.

a. The following document from the United States government is incorporated herein by reference: Standard Industrial Classification Manual, 1987 (U.S. Government Printing Office stock number 041-001-00-314-2).

b. Copies may be obtained from Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954; telephone (202) 512-1800.

4. American Society for Testing and Materials (ASTM).

a. The documents specified below from the American Society for Testing and Materials are incorporated herein by reference.

(1) D323-99a, "Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method)."

(2) D97-96a, "Standard Test Method for Pour Point of Petroleum Products."

(3) D129-00, "Standard Test Method for Sulfur in Petroleum Products (General Bomb Method)."

(4) D388-99, "Standard Classification of Coals by Rank."

(5) D396-98, "Standard Specification for Fuel Oils."

(6) D975-98b, "Standard Specification for Diesel Fuel Oils."

(7) D1072-90(1999), "Standard Test Method for Total Sulfur in Fuel Gases."

(8) D1265-97, "Standard Practice for Sampling Liquefied Petroleum (LP) Gases (Manual Method)."

(9) D2622-98, "Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry."

(10) D4057-95(2000), "Standard Practice for Manual Sampling of Petroleum and Petroleum Products."

(11) D4294-98, "Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectroscopy."

(12) D523-89, "Standard Test Method for Specular Gloss" (1999).

(13) D1613-02, "Standard Test Method for Acidity in Volatile Solvents and Chemical Intermediates Used in Paint, Varnish, Lacquer and Related Products" (2002).

(14) D1640-95, "Standard Test Methods for Drying, Curing, or Film Formation of Organic Coatings at Room Temperature" (1999).

(15) E119-00a, "Standard Test Methods for Fire Tests of Building Construction Materials" (2000).

(16) E84-01, "Standard Test Method for Surface Burning Characteristics of Building Construction Materials" (2001).

(17) D4214-98, "Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films" (1998).

(18) D86-04b, "Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure" (2004).

(19) D4359-90, "Standard Test Method for Determining Whether a Material is a Liquid or a Solid" (reapproved 2000).

(20) E260-96, "Standard Practice for Packed Column Gas Chromatography" (reapproved 2001).

(21) D3912-95, "Standard Test Method for Chemical Resistance of Coatings Used in Light-Water Nuclear Power Plants" (reapproved 2001).

(22) D4082-02, "Standard Test Method for Effects of Gamma Radiation on Coatings for Use in Light-Water Nuclear Power Plants."

(23) F852-99, "Standard Specification for Portable Gasoline Containers for Consumer Use" (reapproved 2006).

(24) F976-02, "Standard Specification for Portable Kerosine and Diesel Containers for Consumer Use."

(25) D4457-02, "Standard Test Method for Determination of Dichloromethane and 1,1,1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph" (reapproved 2008).

(26) D3792-05, "Standard Test Method for Water Content of Coatings by Direct Injection Into a Gas Chromatograph."

(27) D2879-97, "Standard Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope" (reapproved 2007).

b. Copies may be obtained from American Society for Testing Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959; telephone (610) 832-9585.

5. American Petroleum Institute (API).

a. The following document from the American Petroleum Institute is incorporated herein by reference: Evaporative Loss from Floating Roof Tanks, API MPMS Chapter 19, April 1, 1997.

b. Copies may be obtained from American Petroleum Institute, 1220 L Street, Northwest, Washington, DC 20005; telephone (202) 682-8000.

6. American Conference of Governmental Industrial Hygienists (ACGIH).

a. The following document from the ACGIH is incorporated herein by reference: 1991-1992 Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices (ACGIH Handbook).

b. Copies may be obtained from ACGIH, 1330 Kemper Meadow Drive, Suite 600, Cincinnati, OH 45240; telephone (513) 742-2020.

7. National Fire Prevention Association (NFPA).

a. The documents specified below from the National Fire Prevention Association are incorporated herein by reference.

(1) NFPA 385, Standard for Tank Vehicles for Flammable and Combustible Liquids, 2000 Edition.

(2) NFPA 30, Flammable and Combustible Liquids Code, 2000 Edition.

(3) NFPA 30A, Code for Motor Fuel Dispensing Facilities and Repair Garages, 2000 Edition.

b. Copies may be obtained from the National Fire Prevention Association, One Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101; telephone (617) 770-3000.

8. American Society of Mechanical Engineers (ASME).

a. The documents specified below from the American Society of Mechanical Engineers are incorporated herein by reference.

(1) ASME Power Test Codes: Test Code for Steam Generating Units, Power Test Code 4.1-1964 (R1991).

(2) ASME Interim Supplement 19.5 on Instruments and Apparatus: Application, Part II of Fluid Meters, 6th edition (1971).

(3) Standard for the Qualification and Certification of Resource Recovery Facility Operators, ASME QRO-1-1994.

b. Copies may be obtained from the American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016; telephone (800) 843-2763.

9. American Hospital Association (AHA).

a. The following document from the American Hospital Association is incorporated herein by reference: An Ounce of Prevention: Waste Reduction Strategies for Health Care Facilities, AHA Catalog no. W5-057007, 1993.

b. Copies may be obtained from American Hospital Association, One North Franklin, Chicago, IL 60606; telephone (800) 242-2626.

10. Bay Area Air Quality Management District (BAAQMD).

a. The following documents from the Bay Area Air Quality Management District are incorporated herein by reference:

(1) Method 41, "Determination of Volatile Organic Compounds in Solvent-Based Coatings and Related Materials Containing Parachlorobenzotrifluoride" (December 20, 1995).

(2) Method 43, "Determination of Volatile Methylsiloxanes in Solvent-Based Coatings, Inks, and Related Materials" (November 6, 1996).

b. Copies may be obtained from Bay Area Air Quality Management District, 939 Ellis Street, San Francisco, CA 94109, telephone (415) 771-6000.

11. South Coast Air Quality Management District (SCAQMD).

a. The following documents from the South Coast Air Quality Management District are incorporated herein by reference:

(1) Method 303-91, "Determination of Exempt Compounds," in Manual SSMLLABM, "Laboratory Methods of Analysis for Enforcement Samples" (1996).

(2) Method 318-95, "Determination of Weight Percent Elemental Metal in Coatings by X-Ray Diffraction," in Manual SSMLLABM, "Laboratory Methods of Analysis for Enforcement Samples" (1996).

(3) Rule 1174 Ignition Method Compliance Certification Protocol (February 28, 1991).

(4) Method 304-91, "Determination of Volatile Organic Compounds (VOC) in Various Materials," in Manual SSMLLABM, "Laboratory Methods of Analysis for Enforcement Samples" (1996).

(5) Method 316A-92, "Determination of Volatile Organic Compounds (VOC) in Materials Used for Pipes and Fittings" in Manual SSMLLABM, "Laboratory Methods of Analysis for Enforcement Samples" (1996).

(6) "General Test Method for Determining Solvent Losses from Spray Gun Cleaning Systems," October 3, 1989.

b. Copies may be obtained from South Coast Air Quality Management District, 21865 E. Copley Drive, Diamond Bar, CA 91765, telephone (909) 396-2000.

12. California Air Resources Board (CARB).

a. The following documents from the California Air Resources Board are incorporated herein by reference:

(1) Test Method 510, "Automatic Shut-Off Test Procedure for Spill-Proof Systems and Spill-Proof Spouts" (July 6, 2000).

(2) Test Method 511, "Automatic Closure Test Procedure for Spill-Proof Systems and Spill-Proof Spouts" (July 6, 2000).

(3) Method 100, "Procedures for Continuous Gaseous Emission Stack Sampling" (July 28, 1997).

(4) Test Method 513, "Determination of Permeation Rate for Spill-Proof Systems" (July 6, 2000).

(5) Method 310, "Determination of Volatile Organic Compounds (VOC) in Consumer Products and Reactive Organic Compounds in Aerosol Coating Products (Including Appendices A and B)" (May 5, 2005).

(6) California Code of Regulations, Title 17, Division 3, Chapter 1, Subchapter 8.5, Article 1, § 94503.5 (2003).

(7) California Code of Regulations, Title 17, Division 3, Chapter 1, Subchapter 8.5, Article 2, §§ 94509 and 94511 (2003).

(8) California Code of Regulations, Title 17, Division 3, Chapter 1, Subchapter 8.5, Article 4, §§ 94540-94555 (2003).

(9) "Certification Procedure 501 for Portable Fuel Containers and Spill-Proof Spouts, CP-501" (July 26, 2006).

(10) "Test Procedure for Determining Integrity of Spill-Proof Spouts and Spill-Proof Systems, TP-501" (July 26, 2006).

(11) "Test Procedure for Determining Diurnal Emissions from Portable Fuel Containers, TP-502" (July 26, 2006).

b. Copies may be obtained from California Air Resources Board, P.O. Box 2815, Sacramento, CA 95812, telephone (906) 322-3260 or (906) 322-2990.

13. American Architectural Manufacturers Association.

a. The following documents from the American Architectural Manufacturers Association are incorporated herein by reference:

(1) Voluntary Specification 2604-02, "Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels" (2002).

(2) Voluntary Specification 2605-02, "Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels" (2002).

b. Copies may be obtained from American Architectural Manufacturers Association, 1827 Walden Office Square, Suite 550, Schaumburg, IL 60173, telephone (847) 303-5664.

14. American Furniture Manufacturers Association.

a. The following document from the American Furniture Manufacturers Association is incorporated herein by reference: Joint Industry Fabrics Standards Committee, Woven and Knit Residential Upholstery Fabric Standards and Guidelines (January 2001).

b. Copies may be obtained from American Furniture Manufacturers Association, P.O. Box HP-7, High Point, NC 27261; telephone (336) 884-5000.

15. Petroleum Equipment Institute.

a. The following document from the Petroleum Equipment Institute is incorporated herein by reference: Recommended Practices for Installation and Testing of Vapor-Recovery Systems at Vehicle-Fueling Sites, PEI/RP300-09 (2009).

b. Copies may be obtained from Petroleum Equipment Institute, 6931 S. 66th E. Avenue, Suite 310, Tulsa, OK 74133; telephone (918) 494-9696; www.pei.org.

16. American Architectural Manufacturers Association (AAMA).

a. The following documents from the American Architectural Manufacturers Association are incorporated herein by reference:

(1) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels, publication number AAMA 2604-05.

(2) Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels, publication number AAMA 2605-05.

b. Copies may be obtained from American Architectural Manufacturers Association, 1827 Walden Office Square, Suite 550, Schaumburg, IL 60173-4268; telephone (847) 303-5774.

Article 45
Emission Standards for Commercial/Industrial Solid Waste Incinerators (Rule 4-45)

9VAC5-40-6250. Applicability and designation of affected facility.

A. The affected facilities to which the provisions of this article apply are (i) commercial/industrial solid waste incinerator (CISWI) units and air curtain incinerators that commenced construction on or before November 30, 1999,; (ii) CISWI units and air curtain incinerators that commenced construction after November 30, 1999, but no later than on or before June 4, 2010, or that commenced reconstruction or modification on or after June 1, 2001, but no later than August 7, 2013; or (iii) CISWI units other than incinerator units that commenced construction on or before June 4, 2010, or commenced modification after June 4, 2010, but no later than August 7, 2013.

B. The provisions of this article apply throughout the Commonwealth of Virginia.

C. Exempted from the provisions of this article are those units that meet the criteria listed in 40 CFR 60.2555.

D. The provisions of this article do not apply to a CISWI unit if the owner makes changes that meet the definition of modification or reconstruction after August 7, 2013, at which point the CISWI unit becomes subject to subpart CCCC of 40 CFR Part 60.

E. If the owner makes physical or operational changes to an existing CISWI unit primarily to comply with this article, subpart CCCC of 40 CFR Part 60 does not apply to that unit. Such changes do not qualify as modifications or reconstructions under subpart CCCC of 40 CFR Part 60.

F. Each owner shall submit an application for a federal operating permit in accordance with the provisions of 40 CFR 60.2805. Owners to whom this section applies should contact the appropriate regional office for guidance on applying for a federal (Title V) operating permit.

G. The requirement under 40 CFR 60.2555(g)(1) with regard to obtaining a permit under § 3005 of the Solid Waste Disposal Act (42 USC § 6901 et seq.) may be met by obtaining a permit from the department as required by 9VAC5-60 (Virginia Hazardous Waste Management Regulations Air Pollutant Sources).

9VAC5-40-6440. Facility and control equipment maintenance or malfunction.

A. With regard to the emission standards set forth in 9VAC5-40-6360 A, 9VAC5-40-6370 A, 9VAC5-40-6380, and 9VAC5-40-6390, the provisions of 9VAC5-20-180 (Facility and control equipment maintenance or malfunction) apply.

B. With regard to the emission limits in 9VAC5-40-6270, 9VAC5-40-6360 B, and 9VAC5-40-6370 B, the following provisions apply: 1. of 9VAC5-20-180 apply, with the exception of subsections E, F, and G; and 2. 40 CFR 60.2685.

9VAC5-40-6520. Documents incorporated by reference.

A. The United States U.S. Environmental Protection Agency (EPA) regulations promulgated at Subpart DDDD (Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units that Commenced Construction On or Before November 30, 1999) Units) of 40 CFR Part 60 and designated in subsection B of this section are incorporated by reference into this article. The 40 CFR section numbers appearing in subsection B of this section identify the specific provisions incorporated by reference. The specific version of the provisions incorporated by reference shall be that contained in the CFR in effect as specified in 9VAC5-20-21 B.

B. The following documents from the United States U.S. Environmental Protection Agency are incorporated herein by reference:

Model Rule, Increments of Progress

§ 60.2575, What are my requirements for meeting increments of progress and achieving final compliance?

§ 60.2580, When must I complete each increment of progress?

§ 60.2585, What must I include in the notifications of achievement of increments of progress?

§ 60.2590, When must I submit the notifications of achievement of increments of progress?

§ 60.2595, What if I do not meet an increment of progress?

§ 60.2600, How do I comply with the increment of progress for submittal of a control plan?

§ 60.2605, How do I comply with the increment of progress for achieving final compliance?

§ 60.2610, What must I do if I close my CISWI unit and then restart it?

§ 60.2615, What must I do if I plan to permanently close my CISWI unit and not restart it?

Model Rule, Waste Management Plan

§ 60.2620, What is a waste management plan?

§ 60.2625, When must I submit my waste management plan?

§ 60.2630, What should I include in my waste management plan?

Model Rule, Operator Training and Qualification

§ 60.2635, What are the operator training and qualification requirements?

§ 60.2640, When must the operator training course be completed?

§ 60.2645, How do I obtain my operator qualification?

§ 60.2650, How do I maintain my operator qualification?

§ 60.2655, How do I renew my lapsed operator qualification?

§ 60.2660, What site-specific documentation is required?

§ 60.2665, What if all the qualified operators are temporarily not accessible?

Model Rule, Emission Limitations and Operating Limits

§ 60.2670, What emission limitations must I meet and by when?

§ 60.2675, What operating limits must I meet and by when?

§ 60.2680, What if I do not use a wet scrubber, fabric filter, activated carbon injection, selective noncatalytic reduction, an electrostatic precipitator, or a dry scrubber to comply with the emission limitations?

§ 60.2685, Affirmative Defense for Violation of Emission Standards During Malfunction.

Model Rule, Performance Testing

§ 60.2690, How do I conduct the initial and annual performance test?

§ 60.2695, How are the performance test data used?

Model Rule, Initial Compliance Requirements

§ 60.2700, How do I demonstrate initial compliance with the amended emission limitations and establish the operating limits?

§ 60.2705, By what date must I conduct the initial performance test?

§ 60.2706, Reserved By what date must I conduct the initial air pollution control device inspection?

Model Rule, Continuous Compliance Requirements

§ 60.2710, How do I demonstrate continuous compliance with the amended emission limitations and the operating limits?

§ 60.2715, By what date must I conduct the annual performance test?

§ 60.2716, Reserved By what date must I conduct the annual air pollution control device inspection?

§ 60.2720, May I conduct performance testing less often?

§ 60.2725, May I conduct a repeat performance test to establish new operating limits?

Model Rule, Monitoring

§ 60.2730, What monitoring equipment must I install and what parameters must I monitor?

§ 60.2735, Is there a minimum amount of monitoring data I must obtain?

Model Rule, Recordkeeping and Reporting

§ 60.2740, What records must I keep?

§ 60.2745, Where and in what format must I keep my records?

§ 60.2750, What reports must I submit?

§ 60.2755, When must I submit my waste management plan?

§ 60.2760, What information must I submit following my initial performance test?

§ 60.2765, When must I submit my annual report?

§ 60.2770, What information must I include in my annual report?

§ 60.2775, What else must I report if I have a deviation from the operating limits or the emission limitations?

§ 60.2780, What must I include in the deviation report?

§ 60.2785, What else must I report if I have a deviation from the requirement to have a qualified operator accessible?

§ 60.2790, Are there any other notifications or reports that I must submit?

§ 60.2795, In what form can I submit my reports?

§ 60.2800, Can reporting dates be changed?

Model Rule, Title V Operating Permits

§ 60.2805, Am I required to apply for and obtain a Title V operating permit for my unit?

Model Rule, Air Curtain Incinerators

§ 60.2810, What is an air curtain incinerator?

§ 60.2815, What are my requirements for meeting increments of progress and achieving final compliance?

§ 60.2820, When must I complete each increment of progress?

§ 60.2825, What must I include in the notifications of achievement of increments of progress?

§ 60.2830, When must I submit the notifications of achievement of increments of progress?

§ 60.2835, What if I do not meet an increment of progress?

§ 60.2840, How do I comply with the increment of progress for submittal of a control plan?

§ 60.2845, How do I comply with the increment of progress for achieving final compliance?

§ 60.2850, What must I do if I close my air curtain incinerator and then restart it?

§ 60.2855, What must I do if I plan to permanently close my air curtain incinerator and not restart it?

§ 60.2860, What are the emission limitations for air curtain incinerators?

§ 60.2865, How must I monitor opacity for air curtain incinerators?

§ 60.2870, What are the recordkeeping and reporting requirements for air curtain incinerators?

Model Rule, Definitions

§ 60.2875, What definitions must I know?

TABLES

Table 2 to Subpart DDDD of Part 60, Model Rule, Emission Limitations that Apply to Incinerators on or after Before February 7, 2018.

Table 3 to Subpart DDDD of Part 60, Model Rule, Operating Limits for Wet Scrubbers.

Table 4 to Subpart DDDD of Part 60, Model Rule, Toxic Equivalency Factors.

Table 5 to Subpart DDDD of Part 60, Model Rule, Summary of Reporting Requirements.

Table 6 to Subpart DDDD of Part 60, Emission Limitations that Apply to Incinerators on and after February 7, 2018.

Table 7 to Subpart DDDD of Part 60, Emission Limitations that Apply to Energy Recovery Units After May 20, 2011, on or after February 7, 2018.

Table 8 to Subpart DDDD of Part 60, Emission Limitations that Apply to Waste-Burning Kilns after February 7, 2018.

Table 9 to Subpart DDDD of Part 60, Emission Limitations that Apply to Small, Remote Incinerators after February 7, 2018.

VA.R. Doc. No. R17-4814; Filed September 14, 2016, 1:43 p.m.