The Virginia Register OF REGULATIONS is an official state publication issued every other week throughout the year. Indexes are published quarterly, and are cumulative for the year. The Virginia Register has several functions. The new and amended sections of regulations, both as proposed and as finally adopted, are required by law to be published in the Virginia Register. In addition, the Virginia Register is a source of other information about state government, including petitions for rulemaking, emergency regulations, executive orders issued by the Governor, and notices of public hearings on regulations.
ADOPTION, AMENDMENT, AND REPEAL OF REGULATIONS
An agency wishing to adopt, amend, or repeal regulations must first publish in the Virginia Register a notice of intended regulatory action; a basis, purpose, substance and issues statement; an economic impact analysis prepared by the Department of Planning and Budget; the agency’s response to the economic impact analysis; a summary; a notice giving the public an opportunity to comment on the proposal; and the text of the proposed regulation.
Following publication of the proposal in the Virginia Register, the promulgating agency receives public comments for a minimum of 60 days. The Governor reviews the proposed regulation to determine if it is necessary to protect the public health, safety and welfare, and if it is clearly written and easily understandable. If the Governor chooses to comment on the proposed regulation, his comments must be transmitted to the agency and the Registrar no later than 15 days following the completion of the 60-day public comment period. The Governor’s comments, if any, will be published in the Virginia Register. Not less than 15 days following the completion of the 60-day public comment period, the agency may adopt the proposed regulation.
The Joint Commission on Administrative Rules (JCAR) or the appropriate standing committee of each house of the General Assembly may meet during the promulgation or final adoption process and file an objection with the Registrar and the promulgating agency. The objection will be published in the Virginia Register. Within 21 days after receipt by the agency of a legislative objection, the agency shall file a response with the Registrar, the objecting legislative body, and the Governor.
When final action is taken, the agency again publishes the text of the regulation as adopted, highlighting all changes made to the proposed regulation and explaining any substantial changes made since publication of the proposal. A 30-day final adoption period begins upon final publication in the Virginia Register.
The Governor may review the final regulation during this time and, if he objects, forward his objection to the Registrar and the agency. In addition to or in lieu of filing a formal objection, the Governor may suspend the effective date of a portion or all of a regulation until the end of the next regular General Assembly session by issuing a directive signed by a majority of the members of the appropriate legislative body and the Governor. The Governor’s objection or suspension of the regulation, or both, will be published in the Virginia Register. If the Governor finds that changes made to the proposed regulation have substantial impact, he may require the agency to provide an additional 30-day public comment period on the changes. Notice of the additional public comment period required by the Governor will be published in the Virginia Register.
The agency shall suspend the regulatory process for 30 days when it receives requests from 25 or more individuals to solicit additional public comment, unless the agency determines that the changes have minor or inconsequential impact.
A regulation becomes effective at the conclusion of the 30-day final adoption period, or at any other later date specified by the promulgating agency, unless (i) a legislative objection has been filed, in which event the regulation, unless withdrawn, becomes effective on the date specified, which shall be after the expiration of the 21-day objection period; (ii) the Governor exercises his authority to require the agency to provide for additional public comment, in which event the regulation, unless withdrawn, becomes effective on the date specified, which shall be after the expiration of the period for which the Governor has provided for additional public comment; (iii) the Governor and the General Assembly exercise their authority to suspend the effective date of a regulation until the end of the next regular legislative session; or (iv) the agency suspends the regulatory process, in which event the regulation, unless withdrawn, becomes effective on the date specified, which shall be after the expiration of the 30-day public comment period and no earlier than 15 days from publication of the readopted action.
A regulatory action may be withdrawn by the promulgating agency at any time before the regulation becomes final.
FAST-TRACK RULEMAKING PROCESS
Section 2.2-4012.1 of the Code of Virginia provides an exemption from certain provisions of the Administrative Process Act for agency regulations deemed by the Governor to be noncontroversial. To use this process, Governor's concurrence is required and advance notice must be provided to certain legislative committees. Fast-track regulations will become effective on the date noted in the regulatory action if no objections to using the process are filed in accordance with § 2.2-4012.1.
EMERGENCY REGULATIONS
Pursuant to § 2.2-4011 of the Code of Virginia, an agency, upon consultation with the Attorney General, and at the discretion of the Governor, may adopt emergency regulations that are necessitated by an emergency situation. An agency may also adopt an emergency regulation when Virginia statutory law or the appropriation act or federal law or federal regulation requires that a regulation be effective in 280 days or less from its enactment. The emergency regulation becomes operative upon its adoption and filing with the Registrar of Regulations, unless a later date is specified. Emergency regulations are limited to no more than 18 months in duration; however, may be extended for six months under certain circumstances as provided for in § 2.2-4011 D. Emergency regulations are published as soon as possible in the Register.
During the time the emergency status is in effect, the agency may proceed with the adoption of permanent regulations through the usual procedures. To begin promulgating the replacement regulation, the agency must (i) file the Notice of Intended Regulatory Action with the Registrar within 60 days of the effective date of the emergency regulation and (ii) file the proposed regulation with the Registrar within 180 days of the effective date of the emergency regulation. If the agency chooses not to adopt the regulations, the emergency status ends when the prescribed time limit expires.
STATEMENT
The foregoing constitutes a generalized statement of the procedures to be followed. For specific statutory language, it is suggested that Article 2 (§ 2.2-4006 et seq.) of Chapter 40 of Title 2.2 of the Code of Virginia be examined carefully.
CITATION TO THE VIRGINIA REGISTER
The Virginia Register is cited by volume, issue, page number, and date. 29:5 VA.R. 1075-1192 November 5, 2012, refers to Volume 29, Issue 5, pages 1075 through 1192 of the Virginia Register issued on
November 5, 2012.
The Virginia Register of Regulations is published pursuant to Article 6 (§ 2.2-4031 et seq.) of Chapter 40 of Title 2.2 of the Code of Virginia.
Members of the Virginia Code Commission: John S. Edwards, Chairman; Gregory D. Habeeb; James M. LeMunyon; Ryan T. McDougle; Robert L. Calhoun; E.M. Miller, Jr.; Thomas M. Moncure, Jr.; Charles S. Sharp; Robert L. Tavenner; Christopher R. Nolen.
Staff of the Virginia Register: Jane D. Chaffin, Registrar of Regulations; Karen Perrine, Assistant Registrar; Anne Bloomsburg, Regulations Analyst; Rhonda Dyer, Publications Assistant; Terri Edwards, Operations Staff Assistant.
PUBLICATION SCHEDULE AND DEADLINES
Vol. 30 Iss. 16 - April 07, 2014
April 2014 through March 2015
Volume: Issue
|
Material Submitted By Noon*
|
Will Be Published On
|
30:16
|
March 19, 2014
|
April 7, 2014
|
30:17
|
April 2, 2014
|
April 21, 2014
|
30:18
|
April 16, 2014
|
May 5, 2014
|
30:19
|
April 30, 2014
|
May 19, 2014
|
30:20
|
May 14, 2014
|
June 2, 2014
|
30:21
|
May 28, 2014
|
June 16, 2014
|
30:22
|
June 11, 2014
|
June 30, 2014
|
30:23
|
June 25, 2014
|
July 14, 2014
|
30:24
|
July 9, 2014
|
July 28, 2014
|
30:25
|
July 23, 2014
|
August 11, 2014
|
30:26
|
August 6, 2014
|
August 25, 2014
|
31:1
|
August 20, 2014
|
September 8, 2014
|
31:2
|
September 3, 2014
|
September 22, 2014
|
31:3
|
September 17, 2014
|
October 6, 2014
|
31:4
|
October 1, 2014
|
October 20, 2014
|
31:5
|
October 15, 2014
|
November 3, 2014
|
31:6
|
October 29, 2014
|
November 17, 2014
|
31:7
|
November 12, 2014
|
December 1, 2014
|
31:8
|
November 25, 2014 (Tuesday)
|
December 15, 2014
|
31:9
|
December 10, 2014
|
December 29, 2014
|
31:10
|
December 23, 2014 (Tuesday)
|
January 12, 2015
|
31:11
|
January 7, 2015
|
January 26, 2015
|
31:12
|
January 21, 2015
|
February 9, 2015
|
31:13
|
February 4, 2015
|
February 23, 2015
|
31:14
|
February 18, 2015
|
March 9, 2015
|
*Filing deadlines are Wednesdays
unless otherwise specified.
NOTICES OF INTENDED REGULATORY ACTION
Vol. 30 Iss. 16 - April 07, 2014
TITLE 6. CRIMINAL JUSTICE AND CORRECTIONS
Regulations Relating to Criminal History Record Information Use and Security
Notice of Intended Regulatory Action
Notice is hereby given in accordance with § 2.2-4007.01 of the Code of Virginia that the Criminal Justice Services Board intends to consider amending 6VAC20-120, Regulations Relating to Criminal History Record Information Use and Security. The purpose of this regulatory action is a comprehensive review and amendment of existing regulations that mandate and prescribe standards, requirements, and procedures regarding criminal history record information use and security.
The agency intends to hold a public hearing on the proposed action after publication in the Virginia Register.
This Notice of Intended Regulatory Action serves as the report of the findings of the regulatory review pursuant to § 2.2-4007.1 of the Code of Virginia.
Statutory Authority: §§ 9.1-102 and 9.1-131 of the Code of Virginia.
Public Comment Deadline: May 21, 2014.
Agency Contact: Stephanie Morton, Law Enforcement Program Coordinator, Department of Criminal Justice Services, 1100 Bank Street, Richmond, VA 23219, telephone (804) 786-8003, FAX (804) 786-0410, or email stephanie.morton@dcjs.virginia.gov.
VA.R. Doc. No. R14-3370; Filed March 18, 2014, 9:25 a.m.
TITLE 18. PROFESSIONAL AND OCCUPATIONAL LICENSING
Regulations Governing the Practice of Professional Counseling
Withdrawal of Notice of Intended Regulatory Action
Notice is hereby given in accordance with § 2.2-4007.01 of the Code of Virginia that the Board of Counseling has WITHDRAWN the Notice of Intended Regulatory Action (NOIRA) for amending 18VAC115-20, Regulations Governing the Practice of Professional Counseling, which was published in 27:24 VA.R. 2597 August 1, 2011. The regulations were amended as part of the 2013 Regulatory Reform Initiative, and the NOIRA is no longer necessary.
Agency Contact: Catherine Chappell, Executive Director, Board of Counseling, 9960 Mayland Drive, Suite 300, Richmond, VA 23233, telephone (804) 367-4406, FAX (804) 527-4435, or email catherine.chappell@dhp.virginia.gov.
VA.R. Doc. No. R11-2870; Filed March 12, 2014, 9:10 a.m.
TITLE 18. PROFESSIONAL AND OCCUPATIONAL LICENSING
Board for Waterworks and Wastewater Works Operators and Onsite Sewage System Professionals Regulations
Notice of Intended Regulatory Action
Notice is hereby given in accordance with § 2.2-4007.01 of the Code of Virginia that the Board for Waterworks and Wastewater Works Operators and Onsite Sewage System Professionals intends to consider amending 18VAC160-20, Board for Waterworks and Wastewater Works Operators and Onsite Sewage System Professionals Regulations. The purpose of the proposed action is to adjust licensing fees for regulants of the board, which must establish fees adequate to support the costs of the board's operations and a proportionate share of the Department of Professional and Occupational Regulation's operations. By the close of the next biennium, fees will not provide adequate revenue for those costs. The department receives no general fund money but, instead, is funded almost entirely from revenue collected for license and certificate application fees, renewal fees, examination fees, and other licensing fees. The department is self-supporting and must collect adequate revenue to support its mandated and approved activities and operations. Fees must be established at amounts that will provide that revenue. Fee revenue collected on behalf of the various boards funds the department's authorized special revenue appropriation. The board has no other source of revenue from which to fund its operations.
The agency intends to hold a public hearing on the proposed action after publication in the Virginia Register.
Statutory Authority: § 54.1-201 of the Code of Virginia.
Public Comment Deadline: May 7, 2014.
Agency Contact: Trisha Henshaw, Executive Director, Board for Waterworks and Wastewater Works Operators and Onsite Sewage System Professionals, 9960 Mayland Drive, Suite 400, Richmond, VA 23233, telephone (804) 367-8595, FAX (866) 350-5354, or email waterwasteoper@dpor.virginia.gov.
VA.R. Doc. No. R14-3972; Filed March 12, 2014, 9:00 a.m.
TITLE 22. SOCIAL SERVICES
Temporary Assistance for Needy Families (TANF)
Notice of Intended Regulatory Action
Notice is hereby given in accordance with § 2.2-4007.01 of the Code of Virginia that the State Board of Social Services intends to consider amending 22VAC40-295, Temporary Assistance for Needy Families (TANF). The purpose of this action is to amend 22VAC40-295-140 to make the penalties for intentional program violations (IPV) consistent between the TANF Program and the Supplemental Nutrition Assistance Program. The current exclusion time period for an IPV is six months for the first offense and 12 months for the second offense. The proposed change will increase the exclusion time period to 12 months for the first offense and 24 months for the second offense.
The agency does not intend to hold a public hearing on the proposed action after publication in the Virginia Register.
Statutory Authority: § 63.2-217 of the Code of Virginia.
Public Comment Deadline: May 7, 2014.
Agency Contact: Bridget Shelmet, Program Consultant, Department of Social Services, 801 East Main Street, Richmond, VA 23219, telephone (804) 726-7144, FAX (804) 726-7357, or email bridget.shelmet@dss.virginia.gov.
VA.R. Doc. No. R14-3994; Filed March 13, 2014, 11:31 a.m.
REGULATIONS
Vol. 30 Iss. 16 - April 07, 2014
TITLE 6. CRIMINAL JUSTICE AND CORRECTIONS
BOARD OF CORRECTIONS
Final Regulation
Title of Regulation: 6VAC15-40. Minimum Standards for Jails and Lockups (adding 6VAC15-40-985).
Statutory Authority: §§ 53.1-5, 53.1-68, and 53.1-131 of the Code of Virginia.
Effective Date: May 8, 2014.
Agency Contact: Jim Bruce, Agency Regulatory Coordinator, Department of Corrections, P.O. Box 26963, Richmond, VA 23261-6963, telephone (804) 674-3303 ext. 1130, FAX (804) 674-3017, or email james.bruce@vadoc.virginia.gov.
Summary:
The amendments establish procedures pertaining to the use of restraints on pregnant inmates during transportation outside the secure perimeter, during labor and delivery, during postpartum recovery, and when receiving treatment unrelated to labor and delivery. The regulations (i) include criteria and reporting requirements for use of more restrictive restraints and (ii) require staff to annually review policy related to restraining pregnant inmates.
Summary of Public Comments and Agency's Response: A summary of comments made by the public and the agency's response may be obtained from the promulgating agency or viewed at the office of the Registrar of Regulations.
6VAC15-40-985. Restraint of pregnant offenders.
A. This subsection is intended to apply to the transportation outside the secure perimeter such that inmates known to be pregnant shall be handcuffed only in front, unless an individualized determination is made that the inmate is a flight risk or danger to herself or others, or the totality of the circumstances creates a serious security risk.
1. If an individualized determination has been made, then such inmate will be restrained in the least restrictive method necessary for outside transport. Waist chains/belts shall not be used.
2. If it is deemed more restrictive restraints are needed during transport, security staff shall notify a supervisor as soon as reasonably possible and a use of force report indicating the reason for the use of restraints and type of restraints shall be submitted to a supervisor no later than the conclusion of the shift for review and justification.
B. No restraints will be used during labor and delivery unless an individualized determination has been made that the inmate is a flight risk or danger to herself or others, or the totality of the circumstances creates a serious security risk.
C. This subsection is intended to apply to labor and delivery such that if there is an individualized determination that restraints are needed, the least restrictive alternative will be used in consultation with the medical professional, but restraints shall be immediately removed upon the request of any doctor, nurse, or other health professional treating the inmate if the restraints present a threat to the health or life of the inmate or child. Waist chains/belts shall not be used.
D. If it is deemed more restrictive restraints are needed during labor and delivery, security staff shall notify a supervisor as soon as reasonably practical and a use of force report indicating the reason for the use of restraints and type of restraints shall be submitted to a supervisor no later than the conclusion of the shift for review and justification.
E. This subsection is intended to apply during postpartum recovery while the inmate is in the hospital such that after an individualized determination, an inmate shall be restrained in the least restrictive method (i.e., one ankle restraint or one arm restraint) that will allow for the mother's safe handling of her infant and mother-infant bonding, except where necessary when the inmate is a flight risk or danger to herself or others, or the totality of the circumstances creates a serious security risk. If it is deemed restraints more restrictive than one ankle restraint or one arm restraint are needed, security staff shall notify a supervisor as soon as reasonably practical and a use of force report indicating the reason for the use of restraints and type of restraints shall be submitted to a supervisor no later than the conclusion of the shift for review and justification.
F. All staff shall annually review policy related to restraining pregnant inmates.
G. This subsection is intended to apply to inmates known to be pregnant who are in a facility for medical treatment unrelated to labor and delivery. Such inmates will be restrained in the least restrictive method necessary in consultation with the medical professional. Waist chains/belts shall not be used.
VA.R. Doc. No. R12-3078; Filed March 10, 2014, 4:14 p.m.
TITLE 13. HOUSING
BOARD OF HOUSING AND COMMUNITY DEVELOPMENT
Final Regulation
REGISTRAR'S NOTICE: The Board of Housing and Community Development is claiming an exemption from the Administrative Process Act pursuant to § 2.2-4006 A 12 of the Code of Virginia, which excludes regulations adopted pursuant to § 36-98.3 of the Code of Virginia.
Title of Regulation: 13VAC5-31. Virginia Amusement Device Regulations (amending 13VAC5-31-20, 13VAC5-31-30, 13VAC5-31-40, 13VAC5-31-60, 13VAC5-31-75, 13VAC5-31-200, 13VAC5-31-210, 13VAC5-31-290; adding 13VAC5-31-217).
Statutory Authority: § 36-98.3 of the Code of Virginia.
Effective Date: July 14, 2014.
Agency Contact: Stephen W. Calhoun, Regulatory Coordinator, Department of Housing and Community Development, Main Street Centre, 600 East Main Street, Suite 300, Richmond, VA 23219, telephone (804) 371-7000, FAX (804) 371-7090, TTY (804) 371-7089, or email steve.calhoun@dhcd.virginia.gov.
Summary:
This regulatory action amends the Virginia Amusement Device Regulations to correlate with the Department of Housing and Community Development's other building and fire regulations and to adopt newer American Society for Testing and Materials standards. Specific changes are as follows:
1. 13VAC5-31-20 A:
a. In the definition of "amusement device," clarifies the phrase "open to the public" to facilitate a more uniform application of the VADR.
b. Adds a definition of the phrase "certificate of inspection" to mean the certificate or sticker for amusement devices distributed by the department, as referenced in 13VAC5-31-75 E. This amendment requires the use of the department sticker where previously a locality was permitted to use its own.
c. Changes the term "kiddie ride" to "small mechanical ride" and revises the criteria for what qualifies as a small mechanical ride. This amendment is in conjunction with new requirements for inspections in 13VAC5-31-75 D that limit the permit period to a maximum of six months for small mechanical rides.
2. 13VAC5-31-30 A: Adds this subsection to assist local building departments in determining whether certain devices are amusement devices and to achieve more uniformity in the application of the regulation.
3. 13VAC5-31-30 B: Expands the list of exempted equipment or devices.
4. 13VAC5-31-40 A: Updates the list of incorporated standards.
5. 13VAC5-31-75 A: Increases the amount a locality must reduce a permit fee when a private inspector is used, from 50% to 75%; increases permit fees for amusement rides; adds language permitting the increase of fees by a local building department for weekend or after-hour inspections; and adds language authorizing an additional fee for permits and inspections of generators and associated wiring for amusement device events.
6. 13VAC5-31-75 D: Adds language on (i) the minimum time frame for notifying local building departments prior to the operation of a small mechanical ride or an inflatable amusement device, (ii) the inspection fee that a local building department may charge per event where an inflatable amusement device is operating, and (iii) the inspection report required for such inspections.
7. 13VAC5-31-75 E: Clarifies that a local building department may authorize a third-party inspector to post the certification sticker and that permits for small mechanical rides are only valid for a maximum of six months.
8. 13VAC5-31-75 J: Adds this subsection to clarify the procedures for violations of the chapter.
9. 13VAC5-31-75 K: Adds this subsection to clarify that the Virginia Department of General Services functions as the local building department for amusement devices located on state-owned property.
10. 13VAC5-31-217: Adds this section to require that zip lines be operated, maintained, and inspected in accordance with incorporated standards.
13VAC5-31-20. Definitions.
A. The following words and terms when used in this chapter shall have the following meanings unless the context clearly indicates otherwise:
"Amusement device" means (i) a device or structure open to the public by which persons are conveyed or moved in an unusual manner for diversion, but excluding snow tubing parks and rides, ski terrain parks, ski slopes, and ski trails, and (ii) passenger tramways. For the purpose of this definition, the phrase "open to the public" means that the public has full access to a device or structure at an event, irrespective of whether a fee is charged. The use of devices or structures at private events is not considered to be open to the public.
"Bungee cord" means the elastic rope to which the jumper is attached which lengthens and shortens to produce a bouncing action.
"Carabineer" means a shaped metal device with a gate used to connect sections of a bungee cord, jump rigging, equipment, or safety gear.
"Certificate of inspection" means the certificate or sticker for amusement devices distributed by DHCD.
"DHCD" means the Virginia Department of Housing and Community Development.
"Gravity ride" means a ride that is installed on an inclined surface, which depends on gravity for its operation to convey a passenger from the top of the incline to the bottom, and which conveys a passenger in or on a carrier tube, bag, bathing suit, or clothes.
"Ground operator" means a person who assists the jump master to prepare a jumper for jumping.
"Harness" means an assembly to be worn by a bungee jumper to be attached to a bungee cord. It is designed to prevent the wearer from becoming detached from the bungee system.
"Jump master" means a person who has responsibility for the bungee jumper and who takes the jumper through the final stages to the actual jump.
"Jump zone" means the space bounded by the maximum designed movements of the bungee jumper.
"Jumper" means the person who departs from a height attached to a bungee system.
"Kiddie ride" means an amusement device where the passenger or patron height is limited to 54 inches or less, the design capacity of passengers or patrons is 12 or less, and the assembly time for the device is two hours or less.
"Landing area" means the surface area of ground or water directly under the jump zone, the area where the lowering device moves the bungee jumper to be landed away from the jump space and the area covered by the movement of the lowering device.
"Local building department" means the agency or agencies of the governing body of any city, county or town in this Commonwealth charged with the enforcement of the USBC.
"Operating manual" means the document that contains the procedures and forms for the operation of bungee jumping equipment and activity at a site.
"Passenger tramway" means a device used to transport passengers uphill, and suspended in the air by the use of steel cables, chains or belts, or ropes, and usually supported by trestles or towers with one or more spans.
"Platform" means the equipment attached to the structure from which the bungee jumper departs.
"Private inspector" means a person performing inspections who is independent of the company, individual or organization owning, operating or having any vested interest in an amusement device being inspected.
"Small mechanical ride" means an amusement device, other than an inflatable amusement device, where (i) the assembly time for the device is two hours or less, (ii) the revolutions per minute of any rotation of the components of the device is not greater than seven, (iii) the device has a footprint of less than 500 square feet, and (iv) the device does not invert a patron or lift a patron more than three feet in the air, measured from the ground to the bottom of the patron's feet when the device is operating.
"Ultimate tensile strength" means the greatest amount of load applied to a bungee cord prior to failure.
"USBC" means the Virginia Uniform Statewide Building Code (13VAC5-63).
B. Words and terms used in this chapter which are defined in the USBC shall have the meaning ascribed to them in that regulation unless the context clearly indicates otherwise.
C. Words and terms used in this chapter which are defined in the standards incorporated by reference in this chapter shall have the meaning ascribed to them in those standards unless the context clearly indicates otherwise.
13VAC5-31-30. Exemptions Devices covered and exempt.
A. The following devices, identified by name or description, when open to the public shall be considered amusement devices subject to this chapter. The list is intended only to clarify questionable devices, while the definition of an "amusement device" in 13VAC5-31-20 is generally used to determine the applicability of this chapter.
1. Inflatable amusement devices; and
2. Zip lines.
B. The following equipment or devices shall not be considered amusement devices subject to this chapter:
1. Nonmechanized playground or recreational equipment such as swing sets, sliding boards, climbing bars, jungle gyms, skateboard ramps and similar equipment where no admission fee is charged for its use or for admittance to areas where the equipment is located;
2. Coin-operated rides designed to accommodate three or less passengers; and
3. Water slides or similar equipment used in community association, community club or community organization swimming pools.;
4. Mechanical bulls or similar devices;
5. Devices known as mall trains, shopping mall trains, or electric trackless trains for malls; and
6. Devices known as water walking balls, euro bubbles, or similar devices.
13VAC5-31-40. Incorporated standards.
A. The following standards are hereby incorporated by reference for use as part of this chapter:
1. American National Standards Institute (ANSI) Standard No. B77.1-2006 B77.1-2011 for the regulation of passenger tramways; and
2. American Society for Testing and Materials (ASTM) Standard Nos. F698-94 (Reapproved 2000), F747-06, F770-06a F770-11, F846-92 (Reapproved 2003) (2009), F853-05, F893-05a, F1159-03a F893-10, F1159-11, F1193-06, F1305-94 (Reapproved 2002), F1950-99, F1957-99 (Reapproved 2004) (2011), F2007-06, F2137-09, F2291-09b, F2374-07a, F2376-06 [ F2007-11 F2007-12 ], F2137-11, F2291-11, F2374-10, F2375-09, F2376-08, [ and ] F2460-06 F2460-11 [ , and F2959-12 ] for the regulation of amusement devices.
The standards referenced above may be procured from:
ANSI 25 W 43rd Street New York, NY 10036 | ASTM 100 Barr Harbor Dr. West Conshohocken, PA 19428-2959 |
B. The provisions of this chapter govern where they are in conflict with any provisions of the standards incorporated by reference in this chapter.
C. The following requirements supplement the provisions of the ASTM standards incorporated by reference in this chapter:
1. The operator of an amusement device shall be at least 16 years of age, except when the person is under the supervision of a parent or guardian and engaged in activities determined not to be hazardous by the Commissioner of the Virginia Department of Labor and Industry;
2. The amusement device shall be attended by an operator at all times during operation except that (i) one operator is permitted to operate two or more amusement devices provided they are within the sight of the operator and operated by a common control panel or station and (ii) one operator is permitted to operate two kiddie small mechanical rides with separate controls provided the distance between controls is no more than 35 feet and the controls are equipped with a positive pressure switch; and
3. The operator of an amusement device shall not be (i) under the influence of any drugs which may affect the operator's judgment or ability to assure the safety of the public or (ii) under the influence of alcohol.
D. Where an amusement device was manufactured under previous editions of the standards incorporated by reference in this chapter, the previous editions shall apply to the extent that they are different from the current standards.
13VAC5-31-60. Appeals.
Appeals from the local building department concerning the application of this chapter shall be made to the local board of building code appeals established by the USBC. Application for appeal shall be filed with the local building department within 14 calendar days after receipt of the decision of the local building department. The board of appeals shall hear the appeal within seven calendar days after the application for appeal is filed. After final determination by the board, any person who was a party to the appeal may appeal to the State Building Code Technical Review Board, established under § 36-108 of the Code of Virginia, within 14 calendar days of receipt of the decision to be appealed. Such appeal shall be in accordance with the procedures established in the USBC, under the authority granted by § 36-98.3 of the Code of Virginia where the provisions of Chapter 6 (§ 36-97 et seq.) of Title 36 of the Code of Virginia and the USBC apply to amusement devices.
NOTE: Because of the short time frames normally associated with amusement device operations, DHCD staff will be available to assist in finding a timely resolution to disagreements between owners or operators and the local building department upon request by either party.
Part II
Enforcement, Permits and Certificates of Inspection
13VAC5-31-75. Local building department.
A. In accordance with §§ 36-98.3 and 36-105 of the Code of Virginia, the local building department shall be responsible for the enforcement of this chapter and may charge fees for such enforcement activity. The total amount charged for any one permit to operate an amusement device or devices or the renewal of such permit shall not exceed the following, except that when a private inspector is used, the fees shall be reduced by 50% 75%:
1. $25 $35 for each kiddie small mechanical ride or inflatable amusement device covered by the permit;
2. $35 $55 for each circular ride or flat-ride less than 20 feet in height covered by the permit;
3. $55 $75 for each spectacular ride covered by the permit that cannot be inspected as a circular ride or flat-ride in subdivision 2 of this subsection due to complexity or height; [ and ]
4. $150 $200 for each coaster covered by the permit that exceeds 30 feet in height [ .; and
5. The local building department may charge an additional fee for permits and inspections of generators and associated wiring for amusement device events. Generators subject to these fees are those used exclusively with amusement devices and that are inspected by the local building department. The fee per event shall not exceed $165 and shall not exceed the actual cost to perform the inspection or inspections.
Exception: Small portable generators serving only cord and plug connected equipment loads are not subject to the fee. ]
Notwithstanding the above, the local building department shall be permitted to increase the fees up to 50% when requested to perform weekend or after-hour inspections.
B. Notwithstanding the provisions of subsection A of this section, when an amusement device is constructed in whole or in part at a site for permanent operation at that site and is not intended to be disassembled and moved to another site, then the local building department may utilize permit and inspection fees established pursuant to the USBC to defray the cost of enforcement. This authorization does not apply to an amusement device that is only being reassembled, undergoing a major modification at a site or being moved to a site for operation.
C. A permit application shall be made to the local building department at least five days before the date in which the applicant intends to operate an amusement device. The application shall include the name of the owner, operator or other person assuming responsibility for the device or devices, a general description of the device or devices including any serial or identification numbers available, the location of the property on which the device or devices will be operated and the length of time of operation. The permit application shall indicate whether a private inspector will be utilized. If a private inspector is not utilized, the applicant shall give reasonable notice when an inspection is sought and may stipulate the day such inspection is requested provided it is during the normal operating hours of the local building department. In addition to the information required on the permit application, the applicant shall provide proof of liability insurance of an amount not less than $1,000,000 per occurrence or proof of equivalent financial responsibility. The local building department shall be notified of any change in the liability insurance or financial responsibility during the period covered by the permit.
D. Notwithstanding the provisions of subsection C of this section, a permit application is not required for a kiddie small mechanical ride or an inflatable amusement device that has an unexpired a certificate of inspection issued by any local building department in this Commonwealth within a one-year period prior to the dates the small mechanical ride or inflatable amusement device is to be used, regardless of whether the device has been disassembled and moved to a new site. In such cases, the local building department shall be notified at least three days prior to the operation of the kiddie small mechanical ride or the inflatable amusement device and the information required on a permit application as listed in subsection C of this section shall be provided to the local building department. In addition, and notwithstanding the provisions of subsection A of this section, the local building department shall be permitted to charge a $50 inspection fee per event to the person notifying the local building department of an event where an inflatable amusement device is operating, if the local building department chooses to inspect any or all of the inflatable amusement devices operating at that event. An inspection report shall be provided to the person notifying the local building department of the event if such an inspection is conducted.
E. Local building department personnel shall examine the permit application within five days and issue the permit if all requirements are met. A certificate of inspection for each amusement device shall be issued when the device has been found to comply with this chapter by a private inspector or by an inspector from the local building department. It shall be the responsibility of the local building department to verify that the private inspector possesses a valid certificate of competence as an amusement device inspector from the Virginia Board of Housing and Community Development. In addition, local building department personnel shall be responsible for assuring that the certificate of inspection is posted or affixed on or in the vicinity of the device in a location visible to the public. Local building department personnel shall post or affix such certificates or permit the certificates to be posted or affixed by the private inspector. Permits shall indicate the length of time the device or devices will be operated at the site, clearly identify the device or devices to which it applies and the date of expiration of the permit. Permits shall not be valid for longer than one year, except that permits for small mechanical rides shall not be valid for longer than six months.
F. In addition to obtaining a certificate of inspection in conjunction with a permit application for amusement devices permanently fixed to a site, a new certificate of inspection shall also be obtained prior to the operation of an amusement device following a major modification, prior to each seasonal operation of a device, at least once during the operating season and prior to resuming the operation of a device following an order from a local building department to cease operation. This requirement shall not apply to kiddie small mechanical rides meeting the conditions outlined in subsection D of this section.
G. For amusement devices manufactured prior to 1978, the owner or operator shall have the information required by §§ 2.1 through 2.6 of ASTM F698 available at the time of inspection. In addition, the operator of any amusement device shall be responsible for obtaining all manufacturer's notifications, service bulletins and safety alerts issued pursuant to ASTM F853 and the operator shall comply with all recommendations and requirements set out in those documents. A copy of all such documents shall be made available during an inspection.
H. In the enforcement of this chapter, local building department personnel shall have authority to conduct inspections at any time an amusement device would normally be open for operation or at any other time if permission is granted by the owner or operator, to issue an order to temporarily cease operation of an amusement device upon the determination that the device may be unsafe or may otherwise endanger the public and to accept and approve or deny requests for modifications of the rules of this chapter in accordance with the modification provisions of the USBC.
I. In accordance with subdivision 7 of § 36-137 of the Code of Virginia, the local building department shall collect a 2.0% levy of fees charged for permits under this chapter and transmit it quarterly to DHCD to support training programs of the Virginia Building Code Academy. Localities that maintain individual or regional training academies accredited by DHCD shall retain such levy.
J. In accordance with § 36-98.3 of the Code of Virginia and 13VAC5-31-10 B, the procedures for violations of this chapter shall be [ as ] prescribed in the USBC.
K. In accordance with § 36-98.1 of the Code of Virginia, the Virginia Department of General Services (DGS) shall function as the local building department for the application of this chapter to amusement devices located on state-owned property. In accordance with §§ 36-98.2 and 36-114 of the Code of Virginia, appeals of the application of this chapter by the DGS shall be made directly to the State Building Code Technical Review Board. Further, as a condition of this chapter, such appeals shall be filed within 14 calendar days after receipt of the decision of DGS.
Part V
Inflatable Amusement Devices
13VAC5-31-200. General requirements.
In addition to other applicable requirements of this chapter, inflatable amusement devices shall be operated, maintained and inspected in accordance with ASTM F2374.
Notwithstanding any requirements of this chapter to the contrary, a permit to operate an inflatable amusement device that is less than 150 square feet and in which the height of the patron containment area is less than 10 feet need not be obtained if the device has an unexpired certificate of inspection issued by a local building department in this Commonwealth, regardless of whether the device has been disassembled or moved to a new site.
Part VI
Artificial Climbing Walls
13VAC5-31-210. General requirements.
In addition to other applicable requirements of this chapter, artificial climbing walls shall be operated, maintained and inspected in accordance with ASTM F1159.
Notwithstanding any requirements of this chapter to the contrary, an artificial climbing wall may be moved, setup and operated without obtaining a permit provided the wall has a valid certificate of inspection issued by a local building department in this Commonwealth within the prior 90 days and the expiration date of the wire ropes used with the device does not expire within that 90-day period.
[ Part VIII
Zip Lines
13VAC5-31-217. General requirements.
In addition to other applicable requirements of this chapter, zip lines shall be operated, maintained, and inspected in accordance with ASTM F2959. ]
13VAC5-31-290. Requirements.
Amusement devices subject to this part shall comply with applicable requirements of 36 CFR Part 1191–Americans With Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities and; Architectural Barriers Act (ABA) Accessibility Guidelines, (69 FR 44151-44455 (July 23, 2004)).
DOCUMENTS INCORPORATED BY REFERENCE (13VAC5-31)
ANSI B77.1-2011, Passenger Ropeways – Aerial Tramways, Aerial Lifts, Surface Lifts, Tows and Conveyors – Safety Requirements, American National Standards Institute (ANSI), 25 West 43rd Street, 4th Floor, New York, NY 10036 (http://www.ansi.org/)
American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959; (http://www.astm.org/):
F 698 -- 94 (Reapproved 2000) ASTM F698-94, Standard Specification for Physical Information to be Provided for Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 747 -- 06 ASTM F747-06, Standard Terminology Relating to Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 770 -- 06a ASTM F770-11, Standard Practice for Ownership and Operation of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 846 -- 92 (Reapproved 2003) ASTM F846-92 (2009), Standard Guide for Testing Performance of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 853 -- 05 ASTM F853-05, Standard Practice for Maintenance Procedures for Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 893 -- 05a ASTM F893-10, Standard Guide for Inspection of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 1159 -- 03a ASTM F1159-11, Standard Practice for Design and Manufacture of Patron Directed, Artificial Climbing Walls, Dry Slide, Coin Operated and Purposeful Water Immersion Amusement Rides and Devices and Air-Supported Structures, ASTM International, West Conshohocken, PA 19428
F 1193 -- 06 ASTM F1193-06, Standard Practice for Quality, Manufacture, and Construction of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 1305 -- 94 (Reapproved 2002), Standard Guide for Classification of Amusement Rides and Device Related Injuries and Illnesses, ASTM International, West Conshohocken, PA 19428
F 1950 -- 99, Standard Specification for Physical Information to be Transferred With Used Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 1957 -- 99 (Reapproved 2004) ASTM F1957-99 (2011), Standard Test Method for Composite Foam Hardness-Durometer Hardness, ASTM International, West Conshohocken, PA 19428
F 2007 -- 06 ASTM [ F2007-11 F2007-12 ], Standard Practice for Classification, Design, Manufacture, and Operation of Concession Go-Karts and Facilities, ASTM International, West Conshohocken, PA 19428
F 2137 -- 09 ASTM F2137-11, Standard Practice for Measuring the Dynamic Characteristics of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 2291 -- 09b ASTM F2291-11, Standard Practice for Design of Amusement Rides and Devices, ASTM International, West Conshohocken, PA 19428
F 2374 -- 07a ASTM F2374-10, Standard Practice for Design, Manufacture, Operation, and Maintenance of Inflatable Amusement Devices, ASTM International, West Conshohocken, PA 19428
ASTM F2375-09, Standard Practice for Design, Manufacture, Installation and Testing of Climbing Nets and Netting/Mesh used in Amusement Rides, Devices, Play Areas and Attractions
F 2376 -- 06 ASTM F2376-08, Standard Practice for Classification, Design, Manufacture, Construction, and Operation of Water Slide Systems, ASTM International, West Conshohocken, PA 19428
F 2460 -- 06 ASTM F2460-11, Standard Practice for Special Requirements for Bumper Boats, ASTM International, West Conshohocken, PA 19428
[ ASTM F2959-12, Standard Practice for Special Requirements for Aerial Adventure Courses ]
B 77.1 -- 06, Passenger Ropeways – Aerial Tramways, Aerial Lifts, Surface Lifts, Tows and Conveyors – Safety Requirements, ANSI, New York, NY 10036
VA.R. Doc. No. R12-3160; Filed March 14, 2014, 9:53 a.m.
TITLE 13. HOUSING
BOARD OF HOUSING AND COMMUNITY DEVELOPMENT
Final Regulation
Final Regulation
REGISTRAR'S NOTICE: The Board of Housing and Community Development is claiming an exemption from the Administrative Process Act pursuant to § 2.2-4006 A 12 of the Code of Virginia, which excludes regulations adopted by the board pursuant to the Statewide Fire Prevention Code (§ 27-94 et seq. of the Code of Virginia).
Title of Regulation: 13VAC5-51. Virginia Statewide Fire Prevention Code (amending 13VAC5-51-21, 13VAC5-51-31, 13VAC5-51-41, 13VAC5-51-61, 13VAC5-51-81, 13VAC5-51-85, 13VAC5-51-91, 13VAC5-51-111, 13VAC5-51-121, 13VAC5-51-130 through 13VAC5-51-133.5, 13VAC5-51-135 through 13VAC5-51-155; adding 13VAC5-51-133.8, 13VAC5-51-138, 13VAC5-51-138.4, 13VAC5-51-138.8, 13VAC5-51-139, 13VAC5-51-140.5, 13VAC5-51-141, 13VAC5-51-141.5, 13VAC5-51-142, 13VAC5-51-142.5, 13VAC5-51-143.5, 13VAC5-51-144, 13VAC5-51-144.2, 13VAC5-51-144.4, 13VAC5-51-144.6, 13VAC5-51-145.5, 13VAC5-51-146, 13VAC5-51-146.5, 13VAC5-51-147, 13VAC5-51-147.5, 13VAC5-51-151, 13VAC5-51-151.5, 13VAC5-51-152.5, 13VAC5-51-153, 13VAC5-51-154.2, 13VAC5-51-154.4, 13VAC5-51-154.6, 13VAC5-51-154.7, 13VAC5-51-154.8; repealing 13VAC5-51-154.5).
Statutory Authority: § 27-97 of the Code of Virginia.
Effective Date: July 14, 2014.
Agency Contact: Stephen W. Calhoun, Regulatory Coordinator, Department of Housing and Community Development, Main Street Centre, 600 East Main Street, Suite 300, Richmond, VA 23219, telephone (804) 371-7000, FAX (804) 371-7090, TTY (804) 371-7089, or email steve.calhoun@dhcd.virginia.gov.
Summary:
This regulatory action incorporates the newer edition of the International Fire Code (IFC), which is produced by the International Code Council, into the Virginia Statewide Fire Prevention Code (SFPC). Specific changes are outlined below:
1. 13VAC5-51-31 A: Updates the reference to the IFC from the 2009 to the 2012 edition, which is the new nationally recognized model code used in the SFPC.
2. 13VAC5-51-61 C: Clarifies the existing requirement for accepting reports from private or third-party inspectors and references a written policy established by the fire official.
3. 13VAC5-51-81 N: Permits an increase in the fees charged by the State Fire Marshal's Office when there are firework events and the operator fails to notify the office within the appropriate lead time to facilitate inspections.
4. 13VAC5-51-121 M: Adds language to match a statutory requirement that actions under local fire prevention regulations may be appealed to the State Building Code Technical Review Board if the locality does not have a local appeals board designated to hear such appeals.
5. 13VAC5-51-150 V: Adds new requirements for the use of fireworks known as comets and mines. The requirements are based on the fireworks standard of the National Fire Protection Association.
6. 13VAC5-51-85 J: Clarifies that the building official issues permits to install or modify equipment or systems and any other construction.
7. 13VAC5-51-133.5 F: Removes the "on the premises" provision for inspection records; requires tags for kitchen hood or duct system cleaning; and provides an exception for records maintained on site.
8. 13VAC5-51-150: Adds a fee for replacement certificates; authorizes the State Fire Marshal to assemble a panel to provide recommendations involving denials or complaints against certificate holders; requires a permit holder to report accidents involving the use of explosives and fireworks to the State Fire Marshal; replaces the list of required information for blast records with a form; and clarifies the language regarding clearances surrounding firework displays.
Other changes were made for clarification or correlation or to avoid duplication.
13VAC5-51-21. Section 102.0. Applicability.
A. 102.1. General: The provisions of the SFPC shall apply to all matters affecting or relating to structures, processes and premises as set forth in Section 101.0. The SFPC shall supersede any fire prevention regulations previously adopted by a local government or other political subdivision.
B. 102.1.1. Changes: No change shall be made in the use or occupancy of any structure that would place the structure in a different division of the same group of occupancies, unless such structure is made to comply with the requirements of this code and the USBC.
C. 102.2. Application to pre-1973 buildings and structures: Buildings and structures constructed prior to the USBC (1973) shall comply with the maintenance requirements of the SFPC to the extent that equipment, systems, devices, and safeguards which were provided and approved when constructed shall be maintained. Such buildings and structures, if subject to the state fire and public building regulations (Virginia Public Building Safety Regulations, VR 394-01-05) in effect prior to March 31, 1986, shall also be maintained in accordance with those regulations.
D. 102.3. Application to post-1973 buildings and structures: Buildings and structures constructed under any edition of the USBC shall comply with the maintenance requirements of the SFPC to the extent that equipment, systems, devices, and safeguards which were provided and approved when constructed shall be maintained.
E. 102.4. Referenced codes and standards: The codes and standards referenced in the IFC shall be those listed in Chapter 47 80 and considered part of the requirements of the SFPC to the prescribed extent of each such reference. Where differences occur between the provisions of this code and the referenced standards, the provisions of this code shall apply.
F. 102.5. State-owned buildings and structures: The SFPC shall be applicable to all state-owned buildings and structures in the manner and extent described in § 27-99 of the Code of Virginia and the State Fire Marshal shall have the authority to enforce this code in state-owned buildings and structures as is prescribed in §§ 27-98 and 27-99 of the Code of Virginia.
G. 102.6. Relationship to USBC: In accordance with §§ 27-34.4, 36-105.1 and 36-119.1 of the Code of Virginia, the USBC does not supersede the provisions of this code that prescribe standards to be complied with in existing buildings and structures, provided that this code shall not impose requirements that are more restrictive than those of the USBC under which the buildings or structures were constructed. Subsequent alteration, enlargement, rehabilitation, repair or conversion of the occupancy classification of such buildings and structures shall be subject to the construction and rehabilitation provisions of the USBC. Inspection of buildings other than state-owned buildings under construction and the review and approval of building plans for these structures for enforcement of the USBC shall be the sole responsibility of the appropriate local building inspectors.
Upon completion of such structures, responsibility for fire safety protection shall pass to the local fire marshal or official designated by the locality to enforce this code in those localities that enforce the SFPC or to the State Fire Marshal in those localities that do not enforce this code.
H. 102.7. Inspections for USBC requirements: The fire official shall require that existing structures subject to the requirements of the applicable retrofitting provisions relating to the fire protection equipment and system requirements of the USBC, Part I, Construction, Sections Section 103.7 and 3413, comply with the provisions located therein.
13VAC5-51-31. Section 103.0. Incorporation by reference.
A. 103.1. General: The following document is adopted and incorporated by reference to be an enforceable part of the SFPC:
The International Fire Code -- 2009 2012 Edition, hereinafter referred to as "IFC," published by the International Code Council, Inc., 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001-2070, 1-888 422-7233.
B. 103.1.1. Deletion: Delete IFC Chapter 1.
C. 103.1.2. Appendices: The appendices in the IFC are not considered part of the IFC for the purposes of Section 103.1.
Note: Section 101.5 references authority contained in the Code of Virginia for local fire prevention regulations that may be evaluated by localities to determine whether provisions in the IFC appendices may be considered for local fire prevention regulations.
D. 103.2. Amendments: All requirements of the referenced codes and standards that relate to fees, [ non-operational ] permits [ not specifically required by Section 107.2 ], unsafe notices, disputes, condemnation, inspections, scope of enforcement and all other procedural, and administrative matters are deleted and replaced by the provisions of Chapter 1 of the SFPC.
[ Exception: The scope of referenced codes and standards referenced by the SFPC that relate to the maintenance, testing and inspection requirements or limitations shall be enforceable. ]
E. 103.2.1. Other amendments: The SFPC contains provisions adopted by the Virginia Board of Housing and Community Development (BHCD), some of which delete, change or amend provisions of the IFC and referenced standards. Where conflicts occur between such changed provisions and the unchanged provisions of the IFC and referenced standards, the provisions changed by the BHCD shall govern.
Note: The IFC and its referenced standards contain some areas of regulation outside of the scope of the SFPC, as established by the BHCD and under state law. Where conflicts have been readily noted, changes have been made to the IFC and its referenced standards to bring it within the scope of authority; however, in some areas, judgment will have to be made as to whether the provisions of the IFC and its referenced standards are fully applicable.
F. 103.3. International Fire Code. Retroactive fire protection system requirements contained in the IFC shall not be enforced unless specified by the USBC.
13VAC5-51-41. Section 104.0. Enforcement.
A. 104.1. Local enforcement: Any local government may enforce the SFPC following official action by such body. The official action shall (i) require compliance with the provisions of the SFPC in its entirety or with respect only to those provisions of the SFPC relating to open burning, fire lanes, fireworks, and hazardous materials and (ii) assign enforcement responsibility to the local agency or agencies of its choice. Any local governing body may establish such procedures or requirements as may be necessary for the administration and enforcement of this code. If a local governing body elects to enforce only those provisions of the SFPC relating to open burning, it may do so in all or in any designated geographic areas of its jurisdiction. The terms "enforcing agency" and "fire official" are intended to apply to the agency or agencies to which responsibility for enforcement of the SFPC has been assigned. The terms "building official" or "building department" are intended to apply only to the local building official or local building department.
B. 104.1.1. Enforcement of fireworks provisions by law-enforcement officers: In accordance with § 27-100.1 of the Code of Virginia, law-enforcement officers who are otherwise authorized to enforce certain provisions of this code shall not be subject to the certification requirements of [ Sections Section ] 105.2 or 105.3.2.
C. 104.2. State enforcement: In accordance with § 27-98 of the Code of Virginia, the State Fire Marshal shall also have the authority, in cooperation with any local governing body, to enforce the SFPC. The State Fire Marshal shall also have authority to enforce the SFPC in those jurisdictions in which the local governments do not enforce the SFPC and may establish such procedures or requirements as may be necessary for the administration and enforcement of the SFPC in such jurisdictions.
D. 104.3. State structures: Every agency, commission or institution of this Commonwealth, including all institutions of higher education, shall permit, at all reasonable hours, the fire official reasonable access to existing structures or a structure under construction or renovation, for the purpose of performing an informational and advisory fire safety inspection. The fire official is permitted to submit, subsequent to performing such inspection, his findings and recommendations, including a list of corrective actions necessary to ensure that such structure is reasonably safe from the hazards of fire, to the appropriate official of such agency, commission, or institution and the State Fire Marshal. Such agency, commission or institution shall notify, within 60 days of receipt of such findings and recommendations, the State Fire Marshal and the fire official of the corrective measures taken to eliminate the hazards reported by the fire official. The State Fire Marshal shall have the same power in the enforcement of this section as is provided for in § 27-98 of the Code of Virginia. The State Fire Marshal may enter into an agreement as is provided for in § 36-139.4 9.1-208 of the Code of Virginia with any local enforcement agency that enforces the SFPC to enforce this section and to take immediate enforcement action upon verification of a complaint of an imminent hazard such as a chained or blocked exit door, improper storage of flammable liquids, use of decorative materials, and overcrowding.
13VAC5-51-61. Section 106.0. Duties and powers of the fire official.
A. 106.1. General: The fire official shall enforce the provisions of the SFPC as provided herein and as interpreted by the State Building Code Technical Review Board (TRB) in accordance with § 36-118 of the Code of Virginia.
B. 106.2. Delegation of duties and powers: The fire official may delegate duties and powers subject to any limitations imposed by the local governing body. The fire official shall be responsible that any powers and duties delegated are carried out in accordance with this code.
C. 106.3. Inspections: The fire official is authorized to conduct such inspections as are deemed necessary to determine the extent of compliance with the provisions of this code and to approve reports of inspection by approved agencies or individuals in accordance with the fire official's written policy. All reports of such inspections by approved agencies or individuals shall be prepared and submitted in writing for review and approval. Inspection reports shall be certified by a responsible officer of such approved agency or by the responsible individual. The fire official is authorized to engage such expert opinion as deemed necessary to report upon unusual, detailed or complex technical issues in accordance with local policies.
D. 106.3.1. Observations: When, during an inspection, the fire official or an authorized representative observes an apparent or actual violation of another law, ordinance or code not within the official's authority to enforce, such official shall report the findings to the official having jurisdiction in order that such official may institute the necessary measures.
E. 106.4. Alternatives: The SFPC provisions are not intended to prevent the use of any safeguards used to protect life and property from the hazards of fire or explosion that are not specifically prescribed by the SFPC, provided that such alternative safeguards comply with the intent of the SFPC. The alternative safeguard offered shall be, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.
F. 106.5. Modifications: The fire official may grant modifications to any provision of the SFPC upon application by the owner or the owner's agent provided the spirit and intent of the SFPC are observed and public health, welfare, and safety are assured.
Note: The current editions of many nationally recognized model codes and standards are referenced by the SFPC. Future amendments to such codes and standards do not automatically become part of the SFPC; however, the fire official should consider such amendments in deciding whether a modification request should be granted.
G. 106.5.1. Supporting data: The fire official shall require that sufficient technical data be submitted to substantiate the proposed use of any alternative. If it is determined that the evidence presented is satisfactory proof of performance for the use intended, the fire official shall approve the use of such alternative subject to the requirements of this code. The fire official may require and consider a statement from a professional engineer, architect or other competent person as to the equivalency of the proposed modification.
H. 106.5.2. Decision: The application for modification and the final decision of the fire official shall be in writing and shall be recorded in the permanent records of the local enforcing agency.
I. 106.6. Notices and orders: The fire official shall issue all necessary notices or orders to ensure compliance with the SFPC.
J. 106.7. Department records: The fire official shall keep official records of applications received, permits and certificates issued, fees collected, reports of inspections, and notices and orders issued. Such records shall be retained in the official records or disposed of in accordance with General Schedule Number Ten available from The Library of Virginia.
13VAC5-51-81. Section 107.0. Permits and fees.
A. 107.1. Prior notification: The fire official may require notification prior to (i) activities involving the handling, storage or use of substances, materials or devices regulated by the SFPC; (ii) conducting processes which produce conditions hazardous to life or property; or (iii) establishing a place of assembly.
B. 107.2. Permits required: [ Permits Operational permits ] may be required by the fire official as permitted under the SFPC in accordance with Table 107.2, except that the fire official shall require permits for the manufacturing, storage, handling, use, and sale of explosives. In accordance with Section 3301.2.3.1 5601.2.3.1, an application for a permit to manufacture, store, handle, use, or sell explosives shall only be made by a designated individual.
Exception: Such permits shall not be required for the storage of explosives or blasting agents by the Virginia Department of State Police provided notification to the fire official is made annually by the Chief Arson Investigator listing all storage locations.
C. Add Table 107.2 as follows:
Table 107.2. OPERATIONAL PERMIT REQUIREMENTS (to be filled in by local jurisdiction). |
Description | Permit Required (yes or no) | Permit Fee | Inspection Fee |
Aerosol products. An operational permit is required to manufacture, store or handle an aggregate quantity of Level 2 or Level 3 aerosol products in excess of 500 pounds (227 kg) net weight. | | | |
Amusement buildings. An operational permit is required to operate a special amusement building. | | | |
Aviation facilities. An operational permit is required to use a Group H or Group S occupancy for aircraft servicing or repair and aircraft fuel-servicing vehicles. Additional permits required by other sections of this code include, but are not limited to, hot work, hazardous materials and flammable or combustible finishes [ . ] | | | |
Carnivals and fairs. An operational permit is required to conduct a carnival or fair. | | | |
[ Battery systems. An operational permit is required to install stationary lead-acid battery systems having a liquid capacity of more than 50 gallons (189 L). ] | | | |
Cellulose nitrate film. An operational permit is required to store, handle or use cellulose nitrate film in a Group A occupancy. | | | |
Combustible dust-producing operations. An operational permit is required to operate a grain elevator, flour starch mill, feed mill, or a plant pulverizing aluminum, coal, cocoa, magnesium, spices or sugar, or other operations producing combustible dusts as defined in Chapter 2. | | | |
Combustible fibers. An operational permit is required for the storage and handling of combustible fibers in quantities greater than 100 cubic feet (2.8 m3). Exception: An operational permit is not required for agricultural storage. | | | |
Compressed gas. An operational permit is required for the storage, use or handling at normal temperature and pressure (NTP) of compressed gases in excess of the amounts listed below. Exception: Vehicles equipped for and using compressed gas as a fuel for propelling the vehicle. | | | |
Permit Amounts for Compressed Gases | | | |
Type of Gas | Amount (cubic feet at NTP) | | | |
Corrosive | 200 | | | |
Flammable (except cryogenic fluids and liquefied petroleum gases) | 200 | | | |
Highly toxic | Any Amount | | | |
Inert and simple asphyxiant | 6,000 | | | |
Oxidizing (including oxygen) | 504 | | | |
[ Pyrophoric | Any Amount ] | | | |
Toxic | Any Amount | | | |
For SI: 1 cubic foot = 0.02832 m3. | | | |
Covered [ and open ] mall buildings. An operational permit is required for: 1. The placement of retail fixtures and displays, concession equipment, displays of highly combustible goods and similar items in the mall. 2. The display of liquid-fired or gas-fired equipment in the mall. 3. The use of open-flame or flame-producing equipment in the mall. | | | |
Cryogenic fluids. An operational permit is required to produce, store, transport on site, use, handle or dispense cryogenic fluids in excess of the amounts listed below. Exception: Operational permits are not required for vehicles equipped for and using cryogenic fluids as a fuel for propelling the vehicle or for refrigerating the lading. | | | |
Permit Amounts for Cryogenic Fluids | | | |
Type of Cryogenic Fluid | Inside Building (gallons) | Outside Building (gallons) | | | |
Flammable | More than 1 | 60 | | | |
Inert | 60 | 500 | | | |
Oxidizing (includes oxygen) | 10 | 50 | | | |
Physical or health hazard not indicated above | Any Amount | Any Amount | | | |
For SI: 1 gallon = 3.785 L. | | | |
Cutting and welding. An operational permit is required to conduct cutting or welding operations within the jurisdiction. | | | |
Dry cleaning plants. An operational permit is required to engage in the business of dry cleaning or to change to a more hazardous cleaning solvent used in existing dry cleaning equipment. | | | |
Exhibits and trade shows. An operational permit is required to operate exhibits and trade shows. | | | |
Explosives [ , fireworks, and pyrotechnics ]. An operational permit is required for the manufacture, storage, handling, sale or use of any quantity of explosive, explosive [ material materials ], fireworks, [ or ] pyrotechnic special effects [ , or pyrotechnic special effects material ] within the scope of Chapter 33 56. [ Exception: Storage in Group R-3 or R-5 occupancies of smokeless propellant, black powder and small arms primers for personal use, not for resale, and in accordance with the quantity limitations and conditions set forth in Section 5601.1, exception numbers four and 12. ] | | | |
Fire hydrants and valves. An operational permit is required to use or operate fire hydrants or valves intended for fire suppression purposes that are installed on water systems and accessible to a fire apparatus access road that is open to or generally used by the public. Exception: An operational permit is not required for authorized employees of the water company that supplies the system or the fire department to use or operate fire hydrants or valves. | | | |
Flammable and combustible liquids. An operational permit is required: 1. To use or operate a pipeline for the transportation within facilities of flammable or combustible liquids. This requirement shall not apply to the offsite transportation in pipelines regulated by the Department of Transportation (DOTn) (see § 3501.1.2) nor does it apply to piping systems (see § 3503.6). 2. To store, handle or use Class I liquids in excess of 5 gallons (19 L) in a building or in excess of 10 gallons (37.9 L) outside of a building, except that a permit is not required for the following: | | | |
2.1. The storage or use of Class I liquids in the fuel tank of a motor vehicle, aircraft, motorboat, mobile power plant or mobile heating plant, unless such storage, in the opinion of the fire official, would cause an unsafe condition. 2.2. The storage or use of paints, oils, varnishes or similar flammable mixtures when such liquids are stored for maintenance, painting or similar purposes for a period of not more than 30 days. | | | |
3. To store, handle or use Class II or Class IIIA liquids in excess of 25 gallons (95 L) in a building or in excess of 60 gallons (227 L) outside a building, except for fuel oil used in connection with oil-burning equipment. 4. To remove Class I or Class II liquids from an underground storage tank used for fueling motor vehicles by any means other than the approved, stationary on-site pumps normally used for dispensing purposes. 5. To operate tank vehicles, equipment, tanks, plants, terminals, wells, fuel-dispensing stations, refineries, distilleries and similar facilities where flammable and combustible liquids are produced, processed, transported, stored, dispensed or used. 6. To install, alter, remove, abandon, place temporarily out of service (for more than 90 days) or otherwise dispose of an underground, protected above-ground or above-ground flammable or combustible liquid tank. 7. To change the type of contents stored in a flammable or combustible liquid tank to a material that poses a greater hazard than that for which the tank was designed and constructed. 8. To manufacture, process, blend or refine flammable or combustible liquids. | | | |
Floor finishing. An operational permit is required for floor finishing or surfacing operations exceeding 350 square feet (33 m2) using Class I or Class II liquids. | | | |
Fruit and crop ripening. An operational permit is required to operate a fruit- [ ripening ] or crop-ripening facility or conduct a fruit-ripening process using ethylene gas. | | | |
Fumigation [ and, ] thermal [ , and ] insecticidal fogging. An operational permit is required to operate a business of fumigation [ or, ] thermal [ , or ] insecticidal fogging and to maintain a room, vault or chamber in which a toxic or flammable fumigant is used. | | | |
Hazardous materials. An operational permit is required to store, transport on site, dispense, use or handle hazardous materials in excess of the amounts listed below. | | | |
Permit Amounts for Hazardous Materials | | | |
Type of Material | Amount | | | |
Combustible liquids | See flammable and combustible liquids | | | |
Corrosive materials | | | | |
Gases | See compressed gases | | | |
Liquids | 55 gallons | | | |
Solids | 1000 pounds | | | |
Explosive materials | See explosives | | | |
Flammable materials | | | | |
Gases | See compressed gases | | | |
Liquids | See flammable and combustible liquids | | | |
Solids | 100 pounds | | | |
Highly toxic materials | | | | |
Gases | See compressed gases | | | |
Liquids | Any amount | | | |
Solids | Any amount | | | |
Oxidizing materials | | | | |
Gases | See compressed gases | | | |
Liquids | | | | |
Class 4 | Any amount | | | |
Class 3 | 1 gallon [ a ] | | | |
Class 2 | 10 gallons | | | |
Class 1 | 55 gallons | | | |
Solids | | | | |
Class 4 | Any amount | | | |
Class 3 | 10 pounds [ b ] | | | |
Class 2 | 100 pounds | | | |
Class 1 | 500 pounds | | | |
Organic peroxides | | | | |
Liquids | | | | |
Class I | Any amount | | | |
Class II | Any amount | | | |
Class III | 1 gallon | | | |
Class IV | 2 gallons | | | |
Class V | No permit required | | | |
Solids | | | | |
Class I | Any amount | | | |
Class II | Any amount | | | |
Class III | 10 pounds | | | |
Class IV | 20 pounds | | | |
Class V | No permit required | | | |
Pyrophoric materials | | | | |
Gases | See compressed gases | | | |
Liquids | Any amount | | | |
Solids | Any amount | | | |
Toxic materials | | | | |
Gases | See compressed gases | | | |
Liquids | 10 gallons | | | |
Solids | 100 pounds | | | |
Unstable (reactive) materials | | | |
Liquids | | | | |
Class 4 | Any amount | | | |
Class 3 | Any amount | | | |
Class 2 | 5 gallons | | | |
Class 1 | 10 gallons | | | |
Solids | | | | |
Class 4 | Any amount | | | |
Class 3 | Any amount | | | |
Class 2 | 50 pounds | | | |
Class 1 | 100 pounds | | | |
Water reactive materials | | | | |
Liquids | | | |
Class 3 | Any amount | | | |
Class 2 | 5 gallons | | | |
Class 1 | 55 gallons | | | |
Solids | | | | |
Class 3 | Any amount | | | |
Class 2 | 50 pounds | | | |
Class 1 | 500 pounds | | | |
For SI: 1 gallon = 3.785 L, 1 pound = 0.454 kg. [ a. Twenty gallons when Table 5003.1.1(1) Note k applies and hazard identification signs in accordance with Section 5003.5 are provided for quantities of 20 gallons or less. b. Twenty pounds when Table 5003.1.1(1) Note k applies and hazard identification signs in accordance with Section 5003.5 are provided for quantities of 200 pounds or less. ] | | | |
HPM facilities. An operational permit is required to store, handle or use hazardous production materials. | | | |
High piled storage. An operational permit is required to use a building or portion thereof as a high-piled storage area exceeding 500 square feet (46 m2). | | | |
Hot work operations. An operational permit is required for hot work including, but not limited to: 1. Public exhibitions and demonstrations where hot work is conducted. 2. Use of portable hot work equipment inside a structure. Exception: Work that is conducted under a construction permit. 3. Fixed-site hot work equipment such as welding booths. 4. Hot work conducted within a hazardous fire area. 5. Application of roof coverings with the use of an open-flame device. 6. When approved, the fire official shall issue a permit to carry out a Hot Work Program. This program allows approved personnel to regulate their facility's hot work operations. The approved personnel shall be trained in the fire safety aspects denoted in this chapter and shall be responsible for issuing permits requiring compliance with the requirements found in this chapter. These permits shall be issued only to their employees or hot work operations under their supervision. | | | |
Industrial ovens. An operational permit is required for operation of industrial ovens regulated by Chapter 21 30. | | | |
Lumber yards and woodworking plants. An operational permit is required for the storage or processing of lumber exceeding 100,000 board feet (8,333 ft3) (236 m3). | | | |
Liquid-fueled or gas-fueled vehicles or equipment in assembly buildings. An operational permit is required to display, operate or demonstrate liquid-fueled or gas-fueled vehicles or equipment in assembly buildings. | | | |
LP-gas. An operational permit is required for: 1. Storage and use of LP-gas. Exception: An operational permit is not required for individual containers with a 500-gallon (1893 L) water capacity or less [ or multiple container systems having an aggregate quantity not exceeding 500 gallons (1893 L), ] serving occupancies in Group R-3. 2. Operation of cargo tankers that transport LP-gas. | | | |
Magnesium. An operational permit is required to melt, cast, heat treat or grind more than 10 pounds (4.54 kg) of magnesium. | | | |
Miscellaneous combustible storage. An operational permit is required to store in any building or upon any premises in excess of 2,500 cubic feet (71 m3) gross volume of combustible empty packing cases, boxes, barrels or similar containers, rubber tires, rubber, cork or similar combustible material. | | | |
Open burning. An operational permit is required for the kindling or maintaining of an open fire or a fire on any public street, alley, road, or other public or private ground. Instructions and stipulations of the permit shall be adhered to. Exception: Recreational fires. | | | |
Open flames and candles. An operational permit is required to [ remove paint with a torch; use a torch or open-flame device in a hazardous fire area; or to ] use open flames or candles in connection with assembly areas, dining areas of restaurants or drinking establishments. | | | |
[ Open flames and torches. An operational permit is required to remove paint with a torch; or to use a torch or open-flame device in a wildfire risk area. ] | | | |
Organic coatings. An operational permit is required for any organic-coating manufacturing operation producing more than 1 gallon (4 L) of an organic coating in one day. | | | |
[ Assembly/educational Places of assembly ]. An operational permit is required to operate a place of [ assembly /educational occupancy assembly ]. | | | |
Private fire hydrants. An operational permit is required for the removal from service, use or operation of private fire hydrants. Exception: An operational permit is not required for private industry with trained maintenance personnel, private fire brigade or fire departments to maintain, test and use private hydrants. | | | |
Pyrotechnic special effects material. An operational permit is required for use and handling of pyrotechnic special effects material. | | | |
Pyroxylin plastics. An operational permit is required for storage or handling of more than 25 pounds (11 kg) of cellulose nitrate (pyroxylin) plastics and for the assembly or manufacture of articles involving pyroxylin plastics. | | | |
Refrigeration equipment. An operational permit is required to operate a mechanical refrigeration unit or system regulated by Chapter 6. | | | |
Repair garages and service stations. An operational permit is required for operation of repair garages and automotive, marine and fleet service stations. | | | |
Rooftop heliports. An operational permit is required for the operation of a rooftop heliport. | | | |
Spraying or dipping. An operational permit is required to conduct a spraying or dipping operation utilizing flammable or combustible liquids or the application of combustible powders regulated by Chapter 15 24. | | | |
Storage of scrap tires and tire byproducts. An operational permit is required to establish, conduct or maintain storage of scrap tires and tire byproducts that exceeds 2,500 cubic feet (71 m3) of total volume of scrap tires and for indoor storage of tires and tire byproducts. | | | |
Temporary membrane structures and tents. An operational permit is required to operate an air-supported temporary membrane structure or a tent. Exceptions: 1. Tents used exclusively for recreational camping purposes. 2. Tents and air-supported structures that cover an area of 900 square feet (84 m2) or less, including all connecting areas or spaces with a common means of egress or entrance and with an occupant load of 50 or less persons. | | | |
Tire-rebuilding plants. An operational permit is required for the operation and maintenance of a tire-rebuilding plant. | | | |
Waste handling. An operational permit is required for the operation of wrecking yards, junk yards and waste material-handling facilities. | | | |
Wood products. An operational permit is required to store chips, hogged material, lumber or plywood in excess of 200 cubic feet (6 m3). | | | |
| | | | | | |
D. 107.3. Application for permit: Application for a permit shall be made on forms prescribed by the fire official.
E. 107.4. Issuance of permits: Before a permit is issued, the fire official shall make such inspections or tests as are necessary to assure that the use and activities for which application is made comply with the provisions of this code.
F. 107.5. Conditions of permit: A permit shall constitute permission to store or handle materials or to conduct processes in accordance with the SFPC, and shall not be construed as authority to omit or amend any of the provisions of this code. Permits shall remain in effect until revoked or for such period as specified on the permit. Permits are not transferable.
[ G. 107.5.1. Special conditions for the State Fire Marshal's office. Permits issued by the State Fire Marshal's office for the use of explosives in special operations or under emergency conditions shall be valid for one week from the date of issuance and shall not be renewable.
H. 107.6. State Fire Marshal: Permits will not be required by the State Fire Marshal except for those permits listed in Sections 107.13 and 107.14 of this code.
Exception: Such permits shall not be required for the storage of explosives or blasting agents by the Virginia Department of State Police provided notification to the State Fire Marshal is made annually by the Chief Arson Investigator listing all storage locations within areas where enforcement is provided by the State Fire Marshal's office.
I. 107.7. G. 107.6. ] Annual: The enforcing agency may issue annual permits for the manufacturing, storage, handling, use, or sales of explosives to any state regulated public utility.
[ J. 107.8. H. 107.7. ] Approved plans: Plans approved by the fire official are approved with the intent that they comply in all respects to this code. Any omissions or errors on the plans do not relieve the applicant of complying with all applicable requirements of this code.
[ K. 107.9. I. 107.8. ] Posting: Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire official.
[ L. 107.10. J. 107.9. ] Suspension of permit: A permit shall become invalid if the authorized activity is not commenced within six months after issuance of the permit, or if the authorized activity is suspended or abandoned for a period of six months after the time of commencement.
M. 107.11. Revocation of permit: The fire official may revoke a permit or approval issued under the SFPC if conditions of the permit have been violated, or if the approved application, data or plans contain misrepresentation as to material fact.
N. [ M. 107.12. K. 107.10. ] Local fees: In accordance with § 27-97 of the Code of Virginia, fees may be levied by the local governing body in order to defray the cost of enforcement and appeals under the SFPC.
O. [ N. 107.13. L. 107.11. ] State Fire Marshal's office permit fees for explosives, blasting agents, theatrical flame effects, and fireworks: Applications Except as modified herein, applications for firework or pyrotechnic displays shall be submitted to and received by the State Fire Marshal's office not less than 15 days prior to the planned event. [ Fees for permits issued by the State Fire Marshal's office for the storage, use, sale or manufacture of explosives or blasting agents, and for the display of fireworks and flame effects on state-owned property shall be as follows State Fire Marshal's Office permit fees shall be as follows ] :
1. [ $125 $150 ] per year per magazine to store explosives and blasting agents.
2. [ $200 $250 ] per year per city or county to use explosives and blasting agents.
3. [ $150 $200 ] per year to sell explosives and blasting agents.
4. [ $200 $250 ] per year to manufacture explosives, blasting agents and fireworks.
5. $350 the first day of fireworks, pyrotechnics or proximate audience displays conducted in any state-owned building and $150 per day for each consecutive day for identical multi-day events. If an application is received by the State Fire Marshal's office less than 15 days prior to the planned event, the permit fee shall be $450 per $550 the first day and $150 per day for each consecutive day for identical multi-day events. If an application is received by the State Fire Marshal's office less than seven days prior to the planned event, the permit fee shall be $550 per $650 the first day and $150 per day for each consecutive day for identical multi-day events.
6. $250 the first day of fireworks, pyrotechnics or proximate audience displays conducted out-of-doors on any state-owned property and $150 per day for each consecutive day for identical multi-day events. If an application is received by the State Fire Marshal's office less than 15 days prior to the planned event, the permit fee shall be $450 per $550 the first day and $150 per day for each consecutive day for identical multi-day events. If an application is received by the State Fire Marshal's office less than seven days prior to the planned event, the permit fee shall be $550 per $650 the first day and $150 per day for each consecutive day for identical multi-day events.
7. $100 per [ event nonrenewable permit, valid for one week from the date of issuance, ] for the use of explosives in special operations or emergency conditions.
8. $300 the first day for flame effects conducted in accordance with Section [ 308.3.6 308.3.2 ] indoors of any state-owned building or outdoors on state-owned property and [ $150 $200 ] per day for each consecutive day for identical multi-day events, or, if conducted as part of a firework (pyrotechnic) display, [ $100 $150 ] the first day and [ $75 $125 ] per day for each consecutive day for identical multi-day events. If an application for flame effects is received by the State Fire Marshal's office less than 15 days prior to the planned event, the permit fee shall be $450 per $550 the first day and [ $150 $200 ] per day for each consecutive day for identical multi-day events or, if conducted as part of a firework (pyrotechnic) display, $200 the first day and $100 per day for each consecutive day for identical multi-day events. If an application is received by the State Fire Marshal's office less than seven days prior to the planned event, the permit fee shall be $550 per $650 the first day and $150 per day for each consecutive day for identical multi-day events or, if conducted as part of a firework (pyrotechnic) display, $300 the first day and $125 per day for each consecutive day for identical multi-day events.
[ Exception: Permits shall not be required for the storage of explosives or blasting agents by the Virginia Department of State Police provided notification to the State Fire Marshal is made annually by the Chief Arson Investigator listing all storage locations within areas where enforcement is provided by the State Fire Marshal's office. ]
P. [ O. 107.14 M. 107.12. ] State annual [ compliance ] inspection [ permit ] fees. [ Annual fees Fees ] for [ inspection permits issued compliance inspections performed ] by the State Fire Marshal's office [ for the inspection of buildings ] shall be as follows:
1. Nightclubs.
1.1. $350 for occupant load of 100 or less.
1.2. $450 for occupant load of 101 to 200.
1.3. $500 for occupant load of 201 to 300.
1.4. $500 plus $50 for each 100 occupants where occupant loads exceed 300.
2. Private college dormitories with or without assembly areas. If containing assembly areas, such assembly areas are not included in the computation of square footage.
2.1. $150 for 3500 square feet or less.
2.2. $200 for greater than 3500 square feet up to 7000 square feet.
2.3. $250 for greater than 7000 square feet up to 10,000 square feet.
2.4. $250 plus $50 for each additional 3000 square feet where square footage exceeds 10,000.
3. Assembly areas that are part of private college dormitories.
3.1. $50 for 10,000 square feet or less provided the assembly area is within or attached to a dormitory building.
3.2. $100 for greater than 10,000 square feet up to 25,000 square feet provided the assembly area is within or attached to a dormitory building, such as gymnasiums, auditoriums or cafeterias.
3.3. $100 for up to 25,000 square feet provided the assembly area is in a separate or separate buildings such as gymnasiums, auditoriums or cafeterias.
3.4. $150 for greater than 25,000 square feet for assembly areas within or attached to a dormitory building or in a separate or separate buildings such as gymnasiums, auditoriums or cafeterias.
4. Hospitals.
4.1. $300 for 1 to 50 beds.
4.2. $400 for 51 to 100 beds.
4.3. $500 for 101 to 150 beds.
4.4. $600 for 151 to 200 beds.
4.5. $600 plus $100 for each additional 100 beds where the number of beds exceeds 200.
5. [ Child day centers, assisted living facilities and adult day care centers Facilities ] licensed by the Virginia Department of Social Services based on licensed capacity as follows:
5.1. $50 for 1 to 8.
5.2. $75 for 9 to 20.
5.3. $100 for 21 to 50.
5.4. $200 for 51 to 100.
5.5. [ $400 $300 ] for 101 [ or more to 150 ].
[ 5.6. $400 for 151 to 200.
5.7. $500 for 201 or more. ]
Exception: Annual [ compliance ] inspection [ permits fees ] for any building or groups of buildings on the same site may not exceed $2500.
[ 6. Registered complaints.
6.1. No charge for first visit (initial complaint), and if violations are found,
6.2. $51 per hour for each State Fire Marshal's office staff for all subsequent visits.
7. Bonfires (small and large) on state-owned property.
7.1. For a small bonfire pile with a total fuel area more than 3 feet in diameter and more than 2 feet in height, but not more than 9 feet in diameter and not more than 6 feet in height, the permit fee is $50. If an application for a bonfire permit is received by the State Fire Marshal's office less than 15 days prior to the planned event, the permit fee shall be $100. If an application for a bonfire permit is received by the State Fire Marshal's office less than seven days prior to the planned event, the permit fee shall be $150.
7.2. For a large bonfire pile with a total fuel area more than 9 feet in diameter and more than 6 feet in height, the permit fee is $150. If an application for a bonfire permit is received by the State Fire Marshal's office less than 15 days prior to the planned event, the permit fee shall be $300. If an application for a bonfire permit is received by the State Fire Marshal's office less than seven days prior to the planned event, the permit fee shall be $450. ]
Q. [ P. 107.15. N. 107.13. ] Fee schedule: The local governing body may establish a fee schedule. The schedule shall incorporate unit rates, which may be based on square footage, cubic footage, estimated cost of inspection or other appropriate criteria.
R. [ Q. 107.16. O. 107.14. ] Payment of fees: A permit shall not be issued until the designated fees have been paid.
Exception: The fire official may authorize delayed payment of fees.
[ P. 107.14.1. State Fire Marshal's office certification and permit fees not refundable. No refund of any part of the amount paid as a permit or certification fee will be made where the applicant, permit or certification holder, for any reason, discontinued an activity, changed conditions, or changed circumstances for which the permit or certification was issued. However, the permit or certification fee submitted with an application will be refunded if the permit or certification is canceled, revoked, or suspended subsequent to having been issued through administrative error, or if a permit being applied for is to be obtained from a locally appointed fire official. ]
13VAC5-51-85. Section 108.0. Operational permits.
A. 108.1. General. Operational permits shall be in accordance with Section 108. The fire official may require notification prior to (i) activities involving the handling, storage or use of substances, materials or devices regulated by the SFPC; (ii) conducting processes which produce conditions hazardous to life or property; or (iii) establishing a place of assembly.
B. 108.1.1. Permits required. Operational permits may be required by the fire official in accordance with Table 107.2. The fire official shall require operational permits for the manufacturing, storage, handling, use and sale of explosives. Issued permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire official.
Exceptions:
1. Operational permits will not be required by the State Fire Marshal except for the manufacturing, storage, handling, use and sale of explosives in localities not enforcing the SFPC.
2. Operational permits will not be required for the manufacturing, storage, handling or use of explosives or blasting agents by the Virginia Department of State Police provided notification to the fire official is made annually by the Chief Arson Investigator listing all storage locations.
C. 108.1.2. Duration of operational permits.
An operational permit allows the applicant to conduct an operation or a business for which a permit is required by Section 108.1.1 for either:
1. A prescribed period.
2. Until renewed, suspended, or revoked.
D. 108.1.3. Operational permits for the same location. When more than one operational permit is required for the same location, the fire official is authorized to consolidate such permits into a single permit provided that each provision is listed in the permit.
E. 108.2. Application. Application for an operational permit required by this code shall be made to the fire official in such form and detail as prescribed by the fire official. Applications for permits shall be accompanied by such plans as prescribed by the fire official.
F. 108.2.1. Refusal to issue permit. If the application for an operational permit describes a use that does not conform to the requirements of this code and other pertinent laws and ordinances, the fire official shall not issue a permit, but shall return the application to the applicant with the refusal to issue such permit. Such refusal shall, when requested, be in writing and shall contain the reasons for refusal.
G. 108.2.2. Inspection authorized. Before a new operational permit is approved, the fire official is authorized to inspect the receptacles, vehicles, buildings, devices, premises, storage spaces or areas to be used to determine compliance with this code or any operational constraints required.
H. 108.2.3. Time limitation of application. An application for an operational permit for any proposed work or operation shall be deemed to have been abandoned six months after the date of filing, unless such application has been diligently prosecuted or a permit shall have been issued; except that the fire official is authorized to grant one or more extensions of time for additional periods not exceeding 90 days each if there is reasonable cause.
I. 108.2.4. Action on application. The fire official shall examine or cause to be examined applications for operational permits and amendments thereto within a reasonable time after filing. If the application does not conform to the requirements of pertinent laws, the fire official shall reject such application in writing, stating the reasons. If the fire official is satisfied that the proposed work or operation conforms to the requirements of this code and laws and ordinances applicable thereto, the fire official shall issue a permit as soon as practicable.
J. 108.3. Conditions of a permit. An operational permit shall constitute permission to maintain, store or handle materials; or to conduct processes in accordance with the SFPC, and shall not be construed as authority to omit or amend any of the provisions of this code. The building official shall issue permits to install equipment utilized in connection with such activities; or to install or modify any fire protection system or equipment or any other construction, equipment installation or modification in accordance with the provisions of this code where a permit is required by section 108.5. Such permission shall not be construed as authority to omit or amend any of the provisions of this code.
[ Note: The building official issues permits to install equipment utilized in connection with such activities or to install or modify any fire protection system or equipment or any other construction, equipment installation or modification. ]
K. 108.3.1. Expiration. An operational permit shall remain in effect until reissued, renewed, or revoked for such a period of time as specified in the permit. Permits are not transferable and any change in occupancy, operation, tenancy or ownership shall require that a new permit be issued.
L. 108.3.2. Extensions. A permittee holding an unexpired permit shall have the right to apply for an extension of the time within which the permittee will commence work under that permit when work is unable to be commenced within the time required by this section for good and satisfactory reasons. The fire official is authorized to grant, in writing, one or more extensions of the time period of a permit for periods of not more than 90 days each. Such extensions shall be requested by the permit holder in writing and justifiable cause demonstrated.
M. 108.3.3. Annual. The enforcing agency may issue annual operational permits for the manufacturing, storage, handling, use, or sales of explosives to any state regulated public utility.
N. 108.3.4. Suspension of permit. An operational permit shall become invalid if the authorized activity is not commenced within six months after issuance of the permit, or if the authorized activity is suspended or abandoned for a period of six months after the time of commencement.
O. 108.3.5. Posting. Issued operational permits shall be kept on the premises designated therein at all times and shall be readily available for inspection by the fire official.
P. 108.3.6. Compliance with code. The issuance or granting of an operational permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. Operational permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on other data shall not prevent the fire official from requiring the correction of errors in the provided documents and other data. Any addition to or alteration of approved provided documents shall be approved in advance by the fire official, as evidenced by the issuance of a new or amended permit.
Q. 108.3.7. Information on the permit. The fire official shall issue all operational permits required by this code on an approved form furnished for that purpose. The operational permit shall contain a general description of the operation or occupancy and its location and any other information required by the fire official. Issued permits shall bear the original or electronic signature of the fire official or other designee approved by the fire official.
R. 108.4. Revocation. The fire official is authorized to revoke an operational permit issued under the provisions of this code when it is found by inspection or otherwise that there has been a false statement or misrepresentation as to the material facts in the application or documents on which the permit or approval was based including, but not limited to, any one of the following:
1. The permit is used for a location or establishment other than that for which it was issued.
2. The permit is used for a condition or activity other than that listed in the permit.
3. Conditions and limitations set forth in the permit have been violated.
4. Inclusion of any false statements or misrepresentations as to a material fact in the application for permit or plans submitted or a condition of the permit.
5. The permit is used by a different person or firm than the person or firm for which it was issued.
6. The permittee failed, refused or neglected to comply with orders or notices duly served in accordance with the provisions of this code within the time provided therein.
7. The permit was issued in error or in violation of an ordinance, regulation or this code.
13VAC5-51-91. Section 109.0. Inspection.
A. 109.1. Inspection: The fire official may inspect all structures and premises for the purposes of ascertaining and causing to be corrected any conditions liable to cause fire, contribute to the spread of fire, interfere with firefighting operations, endanger life, or any violations of the provisions or intent of the SFPC.
Exception: Single family dwellings and dwelling units in two family and multiple family dwellings and farm structures shall be exempt from routine inspections. This exemption shall not preclude the fire official from conducting routine inspections in Group R-3 or Group R-5 occupancies operating as a commercial bed and breakfast as outlined in Section 310.1 310.3 of the USBC or inspecting under § 27-98.2 of the Code of Virginia for hazardous conditions relating to explosives, flammable and combustible conditions, and hazardous materials.
B. 109.1.1. Right to entry: The fire official may enter any structure or premises at any reasonable time to inspect subject to constitutional restrictions on unreasonable searches and seizures. If entry is refused or not obtained, the fire official may pursue recourse as provided by law.
Note: Specific authorization and procedures for inspections and issuing warrants are set out in §§ 27-98.1 through 27-98.5 of the Code of Virginia and shall be taken into consideration.
C. 109.1.2. Credentials: The fire official and technical assistants shall carry proper credentials of office when inspecting in the performance of their duties under the SFPC.
D. 109.2. Coordinated inspections: The fire official shall coordinate inspections and administrative orders with any other state and local agencies having related inspection authority, and shall coordinate those inspections required by the USBC for new construction when involving provisions of the amended IFC, so that the owners and occupants will not be subjected to numerous inspections or conflicting orders.
Note: The USBC requires the building official to coordinate such inspections with the fire official.
E. 109.3. Other inspections: In accordance with § 36-139.3 9.1-207 of the Code of Virginia, the State Fire Marshal, upon presenting proper credentials, shall make annual inspections for hazards incident to fire in all (i) residential care facilities operated by any state agency, (ii) assisted living facilities licensed or subject to licensure pursuant to Chapter 18 (§ 63.2-1800 et seq.) of Title 63.2 of the Code of Virginia which are not inspected by a local fire marshal, (iii) student-residence facilities owned or operated by the public institutions of higher education in the Commonwealth, and (iv) public schools in the Commonwealth which are not inspected by a local fire marshal. In the event that any such facility or residence is found to be nonconforming to the SFPC, the State Fire Marshal or local fire marshal may petition any court of competent jurisdiction for the issuance of an injunction.
13VAC5-51-111. Section 111.0. Violations.
A. 111.1. Notice: When the fire official discovers an alleged violation of a provision of the SFPC or other codes or ordinances under the fire official's jurisdiction, the fire official shall prepare a written notice citing the section allegedly violated, describing the condition deemed unsafe and specifying time limitations for the required abatements to be made to render the structure or premises safe and secure.
B. 111.1.1. Right of appeal [ .: ] Notices of violation issued under Section 111.1 shall indicate the right of appeal by referencing the appeals section of this code.
Exceptions:
1. Summons issued in lieu of a notice of violation in accordance with Section 111.5 of this code.
2. Documents reflecting uncorrected violations in subsequent inspections to verify compliance.
B. C. 111.2. Service: The written notice of violation of this code shall be served upon the owner, a duly authorized agent or upon the occupant or other person responsible for the conditions under violation. Such notice shall be served either by delivering a copy of same to such persons by mail to the last known post office address, by delivering in person or by delivering it to and leaving it in the possession of any person in charge of the premises, or, in the case such person is not found upon the premises, by affixing a copy thereof in a conspicuous place at the entrance door or avenue of access. Such procedure shall be deemed the equivalent of personal notice.
C. D. 111.3. Failure to correct violations: If the notice of violation is not complied with within the time specified, the fire official shall request the legal counsel of the local governing body to institute the appropriate legal proceedings to restrain, correct, or abate such alleged violation.
D. E. 111.4. Penalty: Penalties upon conviction of violating the SFPC shall be as set out in § 27-100 of the Code of Virginia.
E. F. 111.5. Summons: When authorized and certified in accordance with § 27-34.2 of the Code of Virginia, the fire official may, subject to any limitations imposed by the local governing body, issue a summons in lieu of a notice of violation. Fire officials not certified in accordance with § 27-34.2 of the Code of Virginia may request the law-enforcement agency of the local governing body to make arrests for any alleged violations of the SFPC or orders affecting the immediate public safety.
13VAC5-51-121. Section 112.0. Appeals.
A. 112.1. Local Board of Fire Prevention Code Appeals (BFPCA): Each local governing body which enforces the SFPC shall have a BFPCA to hear appeals as authorized herein or it shall enter into an agreement with the governing body of another county or municipality, with some other agency, or with a state agency approved by the DHCD to act on appeals. An appeal case decided by some other approved agency shall constitute an appeal in accordance with this section and shall be final unless appealed to the State Building Code Technical Review Board (TRB).
B. 112.2. Membership: The BFPCA shall consist of at least five members appointed by the local governing body and having terms of office established by written policy. Alternate members may be appointed to serve in the absence of any regular members and as such, shall have the full power and authority of the regular members. Regular and alternate members may be reappointed. Written records of current membership, including a record of the current chairman and secretary shall be maintained in the office of the local governing body. In order to provide continuity, the terms of the members may be of different length so that less than half will expire in any one-year period. The BFPCA shall meet at least once annually to assure a duly constituted board, appoint officers as necessary and receive such training on the code as may be appropriate or necessary from staff of the locality.
C. 112.2.1. Chairman: The BFPCA shall annually select one of its regular members to serve as chairman. In case of the absence of the chairman at a hearing, the members present shall select an acting chairman.
D. 112.2.2. Secretary: The local governing body shall appoint a secretary to the BFPCA to maintain a detailed record of all proceedings.
E. 112.3. Qualifications of members: BFPCA members shall be selected by the local governing body on the basis of their ability to render fair and competent decisions regarding application of the SFPC and shall, to the extent possible, represent different occupational or professional fields relating to building construction or fire prevention. At least one member should be an experienced builder and one member a licensed professional engineer or architect. Employees or officials of the local governing body shall not serve as members of the BFPCA.
F. 112.4. Disqualification of member: A member shall not hear an appeal in which that member has conflict of interest in accordance with the State and Local Government Conflict of Interests Act, Chapter 31 (§ 2.2-3100 et seq.) of Title 2.2 of the Code of Virginia.
G. 112.5. Application for appeal: The owner of a structure, the owner's agent or any other person involved in the design, construction or maintenance of the structure may appeal a decision of the fire official concerning the application of the SFPC or the fire official's refusal to grant modification under Section 106.5 to the provisions of the SFPC. The appeal shall first lie to the local board of fire prevention code appeals (BFPCA) and then to the TRB except that appeals concerning the application of the SFPC or refusal to grant modifications by the State Fire Marshal shall be made directly to the TRB. The appeal shall be submitted to the BFPCA within 14 calendar days of the application of the SFPC. The application shall contain the name and address of the owner of the structure and the person appealing if not the owner. A copy of the written decision of the fire official shall be submitted along with the application for appeal and maintained as part of the record. The application shall be stamped or otherwise marked by the BFPCA to indicate the date received. Failure to submit an application for appeal within the time limit established by this section shall constitute acceptance of the fire official's decision.
Note: In accordance with § 27-98 of the Code of Virginia, any local fire code may provide for an appeal to a local board of appeals. If no local board of appeals exists, the TRB shall hear appeals of any local fire code violation.
H. 112.6. Notice of meeting: The BFPCA shall meet within 30 calendar days after the date of receipt of the application for appeal. Notice indicating the time and place of the hearing shall be sent to the parties in writing to the addresses listed on the application at least 14 calendar days prior to the date of the hearing. Less notice may be given if agreed upon by the applicant.
I. 112.7. Hearing procedures: All hearings before the BFPCA shall be open to the public. The appellant, the appellant's representative, the local governing body's representative and any person whose interests are affected shall be given an opportunity to be heard. The chairman shall have the power and duty to direct the hearing, rule upon the acceptance of evidence and oversee the record of all proceedings.
J. 112.7.1. Postponement: When a quorum of the BFPCA is not present to hear an appeal, either the appellant or the appellant's representative shall have the right to request a postponement of the hearing. The BFPCA shall reschedule the appeal within 30 calendar days of the postponement.
K. 112.8. Decision: The BFPCA shall have the power to uphold, reverse or modify the decision of the fire official by a concurring vote of a majority of those present. Decisions of the BFPCA shall be final if no appeal is made therefrom and the appellant and the fire official shall act accordingly.
L. 112.8.1. Resolution: The BFPCA "s BFPCA's decision shall be by resolution signed by the chairman and retained as part of the record by the BFPCA. The following wording shall be part of the resolution: "Any person who was a party to the appeal may appeal to the State Building Code Technical Review Board (TRB) by submitting an application to the TRB within 21 calendar days upon receipt by certified mail of this resolution. Application forms are available from the Office of the TRB, 501 North Second 600 East Main Street, Richmond, Virginia 23219, (804) 371-7150." Copies of the resolution shall be furnished to all parties.
M. 112.9. Appeal to the TRB: After final determination by the BFPCA, any person who was a party to the local appeal may appeal to the TRB. Application shall be made to the TRB within 21 calendar days of receipt of the decision to be appealed. Application for appeal to the TRB arising from the SFMO's enforcement of the code or from any local fire code violation if no local board of appeals exists shall be made to the TRB within 14 calendar days of receipt of the decision to be appealed and shall be accompanied by copies of the inspection reports and other relevant information. Failure to submit an application for appeal within the time limit established by this section shall constitute an acceptance of the BFPCA's resolution or fire official's decision.
N. 112.9.1. Information to be submitted: Copies of the fire official's decision and the resolution of the BFPCA shall be submitted with the application for appeal. Upon request by the office of the TRB, the BFPCA shall submit a copy of all inspection reports and all pertinent information from the record of the BFPCA.
O. 112.9.2. Decision of TRB: Procedures of the TRB are in accordance with Article 2 (§ 36-108 et seq.) of Chapter 6 of Title 36 of the Code of Virginia. Decisions of the TRB shall be final if no appeal is made therefrom and the appellant and the code official shall act accordingly.
13VAC5-51-130. IFC Section 202.0. Definitions.
A. Add the following definitions:
Background clearance card: See Section 3302.1 or BCC: An identification card issued to an individual who is not a certified blaster or pyrotechnician and is responsible management or an employee of a company, corporation, firm, or other entity, solely for the purpose of submitting an application to the fire official for a permit to manufacture, use, handle, store, or sell explosive materials; or conduct a fireworks display. A person to whom a BCC has been issued can fulfill the role of a designated individual on an application for a permit to manufacture, use, handle, store, or sell explosive materials; or on an application for a permit to design, setup, and conduct a fireworks display.
Blaster, restricted: See Section 3302.1 Any person engaging in the use of explosives or blasting agents utilizing five pounds (2.25 kg) or less per blasting operation and using instantaneous detonators. A certified restricted blaster can fulfill the role of a designated individual on an application for permit to manufacture, use, handle, store, or sell explosive materials.
Blaster, unrestricted: See Section 3302.1 Any person engaging in the use of explosives or blasting agents without the limit to the amount of explosives or blasting agents or type of detonator. A certified unrestricted blaster can fulfill the role of a designated individual on an application for permit to manufacture, use, handle, store, or sell explosive materials.
Design: For the purposes of a fireworks display, either inside a building or structure or outdoors, it shall mean the pyrotechnician who will be in attendance and makes the final artistic determination for the placement of fireworks and ground display pieces suitable for the display site.
Designated individual: See Section 3302.1 A person who is in possession of a BCC issued by the SFMO, certified by the SFMO as a pyrotechnician, or a restricted or unrestricted blaster, any of whom are responsible for ensuring compliance with state law and regulations relating to blasting agents and explosives and applying for explosives or firework permits; is at least 21 years of age; and demonstrates the capability to effectively communicate safety messages verbally and in writing in the English language.
DHCD: The Virginia Department of Housing and Community Development.
Local government, local governing body or locality: The governing body of any county, city, or town, other political subdivision and state agency in this Commonwealth charged with the enforcement of the SFPC under state law.
Night club: Any building or portion thereof in which the main use is a place of public assembly that provides exhibition, performance or other forms or entertainment; serves alcoholic beverages; and provides music and space for dancing.
Permissible fireworks: Any sparklers, fountains, Pharaoh's serpents, caps for pistols, or pinwheels commonly known as whirligigs or spinning jennies.
Pyrotechnician (firework operator): See Section 3302.1 Any person supervising or engaged in the design, setup, or conducting of any fireworks display, either inside a building or outdoors. A certified pyrotechnician can fulfill the role of a designated individual on an application for a permit for a fireworks display.
Pyrotechnician, aerial: A person supervising or engaged in the design, setup, or conducting of an outdoor aerial fireworks display performed in accordance with the regulations as set forth in this code and NFPA 1123, a referenced standard for fireworks displays.
Pyrotechnician, proximate: A person supervising or engaged in the design, setup, or conducting of a fireworks display, either inside a building or outdoors, performed in accordance with the regulations as set forth in this code and NFPA 1126, a referenced standard for the use of pyrotechnics before a proximate audience.
Responsible management. See Section 3302.1: A person who is any of the following:
1. The sole proprietor of a sole proprietorship.
2. The partners of a general partnership.
3. The managing partners of a limited partnership.
4. The officers [ or directors ] of a corporation.
5. The managers [ or members ] of a limited liability company.
6. The [ managers, ] officers or directors of an association [ , or both ].
7. Individuals in other business entities recognized under the laws of the Commonwealth as having a fiduciary responsibility to the firm.
[ Sky lantern: An unmanned device with a fuel source that incorporates an open flame in order to make the device airborne. ]
Sole proprietor. See Section 3302.1: A person or individual, not a corporation, who is trading under his own name or under an assumed or fictitious name pursuant to the provisions of §§ 59.1-69 through 59.1-76 of the Code of Virginia.
State Fire Marshal: The State Fire Marshal as provided for by § 36-139.2 9.1-206 of the Code of Virginia.
State Regulated Care Facility (SRCF): A building with an occupancy in Group R-2, R-3, R-4, or R-5 occupied by persons in the care of others where program oversight is provided by the Virginia Department of Social Services, the Virginia Department of Behavioral Health and Developmental Services, the Virginia Department of Education or the Virginia Department of Juvenile Justice.
Technical Assistant: Any person employed by or under an extended contract to a local enforcing agency for enforcing the SFPC. For the purposes of this definition, an extended contract shall be a contract with an aggregate term of 18 months or longer.
TRB: The Virginia State Building Code Technical Review Board.
USBC: The Virginia Uniform Statewide Building Code (13VAC5-63).
B. Add the following definition under the term "Occupancy Classification--Residential Group R":
[ Residential Group ] R-5 [ . ] Detached one and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means of egress and their accessory structures. The terms "R-5" and "one and two-family dwelling" where used in this code shall be interchangeable.
C. Change the following definition definitions to read:
Automatic fire-extinguishing system: An approved system of devices and equipment that automatically detects a fire and discharges an approved fire-extinguishing agent onto or in the area of a fire. Such system shall include an automatic sprinkler system, unless otherwise expressly stated.
Fire code official: The officer or other designated authority charged with administration and enforcement of this code, or a duly authorized representative. For the purpose of this code, the terms "code official" and "fire official" shall have the same meaning as the term "fire code official" and, in addition, such official shall have the powers outlined in § 27-98.1 of the Code of Virginia.
Fireworks: Any firecracker, torpedo, skyrocket, or other substance or object, of whatever form or construction, that contains any explosive or inflammable compound or substance, and is intended, or commonly known, as fireworks and that explodes, rises into the air or travels laterally, or fires projectiles into the air. Fireworks shall not include automobile flares, paper caps containing not more than the average of 0.25 grain (16 mg) of explosive content per cap or toy pistols, toy canes, toy guns, or other devices utilizing such caps and items commonly known as party poppers, pop rocks, and snap-n-pops. Fireworks may be further delineated and referred to as:
Fireworks, 1.4G (formerly known as Class C, Common Fireworks): Small fireworks devices containing restricted amounts of pyrotechnic composition designed primarily to produce visible or audible effects by combustion. Such 1.4G fireworks that comply with the construction, chemical composition, and labeling regulations of the DOTn for Fireworks, UN0336, and the U.S. Consumer Product Safety Commission as set forth in CPSC 16 CFR Parts 1500 and 1507, are not explosive materials for the purpose of this code.
Fireworks, 1.3G (formerly Class B, Special Fireworks): Large fireworks devices, which are explosive materials, intended for the use in fireworks displays and designed to produce audible or visible effects by combustion, deflagration, or detonation. Such 1.3G fireworks include, but are not limited to, firecrackers containing more than 130 milligrams (2 grains) of explosive composition, aerial shells containing more than 40 grams of pyrotechnic composition, and other display pieces that exceed the limits for classification as 1.4G fireworks. Such 1.3G fireworks are also described as Fireworks, UN0335 by the DOTn.
Smokeless propellants [ .: ] Solid propellants, commonly referred to as smokeless powders or any propellant classified by DOTn as a smokeless propellant in accordance with NA3178, Smokeless Powder for Small Arms, used in small arms ammunition, firearms, cannons, rockets, propellant-actuated devices, and similar articles.
13VAC5-51-131. IFC Chapter 3. Precautions Against Fire General Requirements.
A. [ Change Section 301.2 to read:
301.2. Permits. Permits shall be required as set forth in Section 107.2 for the activities or uses regulated by Sections 306, 307, 308, and 315.
B. ] Add Section 301.3 to read:
301.3. Occupancy. The occupancy of a structure shall be continued as originally permitted under and in full compliance with the codes in force at the time of construction or alteration. The occupancy of a structure shall not change to another occupancy that will subject the structure to any special provisions of this code or the USBC without the approval of the building official.
[ B. C. Add the following to the list of definitions in Section 302.1:
Sky lantern.
D. ] Change Section 304.3.2 to read:
304.3.2. Capacity exceeding 5.88 cubic feet. Containers with a capacity exceeding 5.88 cubic feet (44 gallons) (0.17 m³) shall be provided with lids. Containers and lids shall be constructed of noncombustible materials or approved combustible materials.
[ C. E. Add an exception to Section 307.1 to read:
Exception: Approved outdoor live fire training using equipment or appliances accessible or available to the general public, and that complies with Section 307.4.
F. Change Section 307.2 to read:
307.2. Permit required. A permit shall be obtained from the fire code official in accordance with Section 107.2 prior to kindling a fire for recognized silvicultural or range or wildlife management practices, prevention or control of disease or pests, or a bonfire. Application for such approval shall only be presented by and permits issued to the owner of the land upon which the fire is to be kindled.
G. Add Section 308.1.6.3 to read:
308.1.6.3. Sky lanterns. No person shall release or cause to be released an untethered sky lantern.
H. Change Section 308.2 to read:
308.2. Permits required. Permits shall be obtained from the fire code official in accordance with Section 107.2 prior to engaging in the following activities involving open flame, fire, and burning:
1. Use of a torch or flame-producing device to remove paint from a structure.
2. Use of open flame, fire, or burning in connection with Group A or E occupancies.
3. Use or operation of torches and other devices, machines, or processes liable to start or cause fire in or upon wildfire risk areas.
I. Change Section 311.1 to read:
311.1. General. Temporarily unoccupied buildings, structures, premises, or portions thereof, including tenant spaces, shall be safeguarded and maintained in accordance with Sections 311.1.1 through 311.5.6.
J. ] Add Section 311.5.6 to read:
311.5.6. Removal. Removal of placards posted in accordance with this section without the approval of the fire official shall be a violation of this code.
[ K. Add Section 311.6 to read:
311.6. Unoccupied tenant spaces in mall buildings. Unoccupied tenant spaces in covered and open mall buildings shall be:
1. Kept free from the storage of any materials.
2. Separated from the remainder of the building by partitions of at least 0.5-inch-thick (12.7 mm) gypsum board or an approved equivalent to the underside of the ceiling of the adjoining tenant spaces.
3. Without doors or other access openings other than one door that shall be kept key locked in the closed position except during that time when opened for inspection.
4. Kept free from combustible waste and be broom swept clean. ]
C. [ D. L. ] Change Section 314.1 to read:
314.1. General. Indoor displays constructed within any building or structure shall comply with Sections 314.2 through 314.5.
D. [ E. M. ] Add Section 314.5 to read:
314.5. Smokeless powder and small arms primers. Venders shall not store, display, or sell smokeless powder or small arms primers during trade shows inside exhibition halls except as follows:
1. The amount of smokeless powder displayed by each vender is limited to the amount established in Section 3306.5.1.1 5506.5.1.1.
2. The amount of smokeless powder each vender may store is limited to the storage arrangements and storage amounts established in Section 3306.5.2.1 5506.5.2.1. Smokeless powder shall remain in the manufacturer's original sealed container, and the container shall remain sealed while inside the building. The repackaging of smokeless powder shall not be performed inside the building. Damaged containers shall not be repackaged inside the building and shall be immediately removed from the building in such manner to avoid spilling any powder.
3. There shall be at least 50 feet separation between venders and 20 feet from any exit.
4. Small arms primers shall be displayed and stored in the manufacturer's original packaging and in accordance with the requirements of Section 3306.5.2.3 5506.5.2.3.
[ N. Change Section 315.2 to read:
315.2. Permit required. A permit for miscellaneous combustible storage shall be required as set forth in Section 107.2. ]
E. [ F. O. ] Change Section 315.3 315.4 to read:
315.3 315.4. Outside storage. Outside storage of combustible materials shall not be located within 10 feet (3048 mm) of a property line or other building on the site.
Exceptions:
1. The separation distance is allowed to be reduced to 3 feet (914 mm) for storage not exceeding 6 feet (1829 mm) in height.
2. The separation distance is allowed to be reduced when the fire official determines that no hazard to the adjoining property exists.
F. [ G. P. ] Change Section 315.3.1 315.4.1 to read:
315.3.1 315.4.1. Storage beneath overhead projections from buildings. To the extent required by the code the building was constructed under, when buildings are required to be protected by automatic sprinklers, the outdoor storage, display, and handling of combustible materials under eaves, canopies, or other projections or overhangs is prohibited except where automatic sprinklers are installed under such eaves, canopies, or other projections or overhangs.
13VAC5-51-132. IFC Chapter 4. Emergency Planning and Preparedness.
A. Add Section 401.1.1 to read:
401.1.1. State Regulated Care Facilities: when. When a state license is required by the Virginia Department of Social Services; Virginia Department of Behavioral Health and Developmental Services; Virginia Department of Education; or Virginia Department of Juvenile Justice to operate, SRCF shall comply with this section and the provisions of Section 404.0.
[ B. Add item ] 15 [ 16 to Section 404.2 to read: ]
15. [ 16. SRCF.
C. Add exception to Section 405.1 to read:
Exception: Emergency evacuation drills shall not be conducted in school buildings during periods of mandatory testing required by the Virginia Board of Education.
D. ] Add [ Delete the "High-rise buildings" category, and add the following category to Table 405.2 to read:
Group or occupancy | Frequency | Participation |
SRCF | Monthly | All occupants |
E. Add Section 405.2.1 to read:
405.2.1. High-rise buildings. Fire exit drills shall be conducted annually by building staff personnel or the owner of the building in accordance with the fire safety plan and shall not affect other current occupants.
F. Add Section 408.1.1 to read:
408.1.1. Maintaining occupant load posting. Occupant load postings required by the building code are required to be maintained.
G. Change Section 408.2 to read:
408.2. Group A occupancies. Group A occupancies shall comply with applicable requirements of Sections 408.2.1 through 408.2.3 and 401 through 406.
H. Add Sections 408.2.3, 408.2.3.1 and 408.2.3.2 to read:
408.2.3. Night clubs. Night clubs shall comply with Sections 408.2.3.1 and 408.2.3.2.
408.2.3.1. Audible announcements. Audible announcements shall be made to the occupants no longer than 10 minutes prior to the start of the entertainment and at each intermission to notify the occupants of the location of the exits to be used in the event of a fire or other emergency.
408.2.3.2. Occupant load count. Upon request of the fire code official, the owner or operator, or both, will be required to keep a running count of the occupant load to provide to the fire code official during performance hours of operation, entertainment hours of operation, or both.
B. Change Section 403 to read:
Section 403.
Emergency Preparedness Requirements.
403.1. General. In addition to the requirements of Section 401, occupancies, uses and outdoor locations shall comply with the emergency preparedness requirements set forth in Sections 403.2 through 403.11. Where a fire safety and evacuation plan is required by Sections 403.2 through 403.11, evacuation drills shall be in accordance with Section 405 and employee training shall be in accordance with Section 406.
403.1.1. Maintaining occupant load posting. Occupant load postings required by the building code are required to be maintained.
403.2. Group A occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group A occupancies, other than those occupancies used exclusively for purposes of religious worship with an occupant load less than 2,000, and for buildings containing both a Group A occupancy and an atrium. Group A occupancies shall also comply with Sections 403.2.1 through 403.2.4.
403.2.1. Seating plan. In addition to the requirements of Section 404.2, the fire safety and evacuation plans for assembly occupancies shall include a detailed seating plan, occupant load and occupant load limit. Deviations from the approved plans shall be allowed provided the occupant load limit for the occupancy is not exceeded and the aisles and exit accessways remain unobstructed.
403.2.2. Announcements. In theaters, motion picture theaters, auditoriums and similar assembly occupancies in Group A used for noncontinuous programs, an audible announcement shall be made not more than 10 minutes prior to the start of each program to notify the occupants of the location of the exits to be used in the event of a fire or other emergency.
Exception: In motion picture theaters, the announcement is allowed to be projected upon the screen in a manner approved by the fire code official.
403.2.2.1. Night clubs. Night clubs shall comply with Sections 403.2.2.1.1 and 403.2.2.1.2.
403.2.2.1.1. Audible announcements. Audible announcements shall be made to the occupants no longer than 10 minutes prior to the start of the entertainment and at each intermission to notify the occupants of the location of the exits to be used in the event of a fire or other emergency.
403.2.2.1.2. Occupant load count. Upon request of the fire code official, the owner or operator, or both, will be required to keep a running count of the occupant load to provide to the fire code official during performance hours of operation, entertainment hours of operation, or both.
403.2.3. Fire watch personnel. Fire watch personnel shall be provided where required by Section 403.11.1.
403.2.4. Crowd managers. Crowd managers shall be provided where required by Section 403.11.3.
403.3. Group B occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for buildings containing a Group B occupancy where the Group B occupancy has an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge.
403.4. Group E occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group E occupancies and for buildings containing both a Group E occupancy and an atrium. Group E occupancies shall also comply with Section 403.4.1.
403.4.1. Group E occupancies. Group E occupancies shall comply with 403.4.1.1 through 403.4.1.3.
403.4.1.1. First emergency evacuation drill. The first emergency evacuation drill of each school year shall be conducted within 10 days of the beginning of classes.
403.4.1.2. Time of day. Emergency evacuation drills shall be conducted at different hours of the day or evening, during the changing of classes, when the school is at assembly, during the recess or gymnastic periods, or during other times to avoid distinction between drills and actual fires.
403.4.1.3. Assembly points. Outdoor assembly areas shall be designated and shall be located a safe distance from the building being evacuated so as to avoid interference with fire department operations. The assembly areas shall be arranged to keep each class separate to provide accountability of all individuals.
403.5. Group F occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for buildings containing a Group F occupancy where the Group F occupancy has an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge.
403.6. Group H occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group H occupancies. Group H-5 occupancies shall also comply with Section 403.6.1.
403.6.1. Group H-5 occupancies. Group H-5 occupancies shall comply with Sections 403.6.1.1 through 403.6.1.4.
403.6.1.1. Plans and diagrams. In addition to the requirements of Section 404 and Section 407.6, plans and diagrams shall be maintained in approved locations indicating the approximate plan for each area; the amount and type of HPM stored, handled and used; locations of shutoff valves for HPM supply piping; emergency telephone locations; and locations of exits.
403.6.1.2. Plan updating. The plans and diagrams required by Section 404, 403.6.1.1 and 407.6 shall be maintained up to date and the fire code official and fire department shall be informed of major changes.
403.6.1.3. Emergency response team. Responsible persons shall be designated as an on-site emergency response team and trained to be liaison personnel for the fire department. These persons shall aid the fire department in preplanning emergency responses; identifying locations where HPM is stored, handled and used; and be familiar with the chemical nature of such material. An adequate number of personnel for each work shift shall be designated.
403.6.1.4. Emergency drills. Emergency drills of the on-site emergency response team shall be conducted on a regular basis but not less than once every three months. Records of drills conducted shall be maintained.
403.7. Group I occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group I occupancies. Group I occupancies shall also comply with Sections 403.7.1 through 403.7.3.
403.7.1. Group I-1 occupancies. Group I-1 occupancies shall comply with Sections 403.7.1.1 through 403.7.1.6.
403.7.1.1. Fire safety and evacuation plan. The fire safety and evacuation plan required by Section 404 shall include special employee actions, including fire protection procedures necessary for residents, and shall be amended or revised upon admission of any resident with unusual needs.
403.7.1.2. Employee training. Employees shall be periodically instructed and kept informed of their duties and responsibilities under the plan. Such instruction shall be reviewed by employees at intervals not exceeding two months. A copy of the plan shall be readily available at all times within the facility.
403.7.1.3. Resident training. Residents capable of assisting in their own evacuation shall be trained in the proper actions to take in the event of a fire. The training shall include actions to take if the primary escape route is blocked. Where the resident is given rehabilitation or habilitation training, training in fire prevention and actions to take in the event of a fire shall be a part of the rehabilitation training program. Residents shall be trained to assist each other in case of fire to the extent their physical and mental abilities permit them to do so without additional personal risk.
403.7.1.4. Drill frequency. Emergency evacuation drills shall be conducted at least six times per year, two times per year on each shift. Twelve drills shall be conducted in the first year of operation.
403.7.1.5. Drill times. Drills times are not required to comply with Section 405.4.
403.7.1.6. Resident participation in drills. Emergency evacuation drills shall involve the actual evacuation of residents to a selected assembly point.
403.7.2. Group I-2 occupancies. Group I-2 occupancies shall comply with Sections 403.7.2.1 through 403.7.2.3.
403.7.2.1. Drill times. Drill times are not required to comply with Section 405.4.
403.7.2.2. Evacuation not required. During emergency evacuation drills, the movement of patients to safe areas or to the exterior of the building is not required.
403.7.2.3. Coded alarm signal. When emergency evacuation drills are conducted after visiting hours or when patients or residents are expected to be asleep, a coded announcement is allowed instead of audible alarms.
403.7.3. Group I-3 occupancies. Group I-3 occupancies shall comply with Sections 403.7.3.1 through 403.7.3.4.
403.7.3.1. Employee training. Employees shall be instructed in the proper use of portable fire extinguishers and other manual fire suppression equipment. Training of new employees shall be provided promptly upon entrance on duty. Refresher training shall be provided at least annually.
403.7.3.2. Employee staffing. Group I-3 occupancies shall be provided with 24-hour staffing. An employee shall be within three floors or 300 feet (91 440 mm) horizontal distance of the access door of each resident housing area. In Conditions 3, 4 and 5, as defined in "Occupancy Classification – Institutional Group I-3" in Chapter 2, the arrangement shall be such that the employee involved can start release of locks necessary for emergency evacuation or rescue and initiate other necessary emergency actions within 2 minutes of an alarm.
Exception: An employee shall not be required to be within three floors or 300 feet (9144 mm) in areas in which all locks are unlocked remotely and automatically in accordance with Section 408.4 of the International Building Code.
403.7.3.3. Notification. Provisions shall be made for residents in Conditions 3, 4 and 5, as defined in "Occupancy Classification – Institutional Group I-3" in Chapter 2, to readily notify an employee of an emergency.
403.7.3.4. Keys. Keys necessary for unlocking doors installed in a means of egress shall be individually identifiable by both touch and sight.
403.8. Group M occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for buildings containing a Group M occupancy, where the Group M occupancy has an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge, and for buildings containing both a Group M occupancy and an atrium.
403.9. Group R occupancies. Group R occupancies shall comply with the provisions of this section applicable to the type of Group R occupancy.
403.9.1. Group R-1 occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group R-1 occupancies. Group R-1 occupancies shall also comply with Sections 403.9.1.1 through 403.9.1.3.
403.9.1.1. Evacuation diagrams. A diagram depicting two evacuation routes shall be posted on or immediately adjacent to every required egress door from each hotel or motel sleeping unit.
403.9.1.2. Emergency duties. Upon discovery of a fire or suspected fire, hotel and motel employees shall perform the following duties:
1. Activate the fire alarm system, where provided.
2. Notify the public fire department.
3. Take other action as previously instructed.
403.9.1.3. Fire safety and evacuation instructions. Information shall be provided in the fire safety and evacuation plan required by Section 404 to allow guests to decide whether to evacuate to the outside, evacuate to an area of refuge, remain in place, or any combination of the three.
403.9.2. Group R-2 occupancies. Group R-2 occupancies shall comply with Sections 403.9.2.1 through 403.9.2.3.
403.9.2.1. College and university buildings. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group R-2 college and university buildings. Group R-2 college and university buildings shall also comply with Sections 403.9.2.1.1 and 403.9.2.1.2.
403.9.2.1.1. First emergency evacuation drill. The first emergency evacuation drill of each school year shall be conducted within 10 days of the beginning of classes.
403.9.2.1.2. Time of day. Emergency evacuation drills shall be conducted at different hours of the day or evening, during the changing of classes, when the school is at assembly, during the recess or gymnastic periods, or during other times to avoid distinction between drills and actual fires. One required drill shall be held during hours after sunset or before sunrise.
403.9.2.2. Emergency guide. Fire emergency guides shall be provided for Group R-2 occupancies. Guide contents, maintenance and distribution shall comply with Sections 403.9.2.2.1 through 403.9.2.2.3.
403.9.2.2.1. Guide contents. Fire emergency guides shall describe the location, function and use of fire protection equipment and appliances accessible to residents, including fire alarm systems, smoke alarms, and portable fire extinguishers. Guides shall also include an emergency evacuation plan for each dwelling unit.
403.9.2.2.2. Emergency guide maintenance. Emergency guides shall be reviewed and approved by the fire code official.
403.9.2.2.3. Emergency guide distribution. A copy of the emergency guide shall be given to each tenant prior to initial occupancy.
403.9.2.3. Evacuation diagrams for dormitories. A diagram depicting two evacuation routes shall be posted on or immediately adjacent to every required egress door from each dormitory sleeping unit. Evacuation diagrams shall be reviewed and updated as needed to maintain accuracy.
403.9.3. Group R-4 occupancies. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group R-4 occupancies. Group R-4 occupancies shall also comply with Sections 403.9.3.1 through 403.9.3.6.
403.9.3.1. Fire safety and evacuation plan. The fire safety and evacuation plan required by Section 404 shall include special employee actions, including fire protection procedures necessary for residents, and shall be amended or revised upon admission of a resident with unusual needs.
403.9.3.2. Employee training. Employees shall be periodically instructed and kept informed of their duties and responsibilities under the plan. Such instruction shall be reviewed by employees at intervals not exceeding two months. A copy of the plan shall be readily available at all times within the facility.
403.9.3.3. Resident training. Residents capable of assisting in their own evacuation shall be trained in the proper actions to take in the event of a fire. The training shall include actions to take if the primary escape route is blocked. Where the resident is given rehabilitation or habilitation training, training in fire prevention and actions to take in the event of a fire shall be a part of the rehabilitation training program. Residents shall be trained to assist each other in case of fire to the extent their physical and mental abilities permit them to do so without additional personal risk.
403.9.3.4. Drill frequency. Emergency evacuation drills shall be conducted at least six times per year, two times per year on each shift. Twelve drills shall be conducted in the first year of operation.
403.9.3.5. Drill times. Drills are not required to comply with Section 405.4.
403.9.3.6. Resident participation in drills. Emergency evacuation drills shall involve the actual evacuation of residents to a selected assembly point and shall provide residents with experience in exiting through all required exits. All required exits shall be used during emergency evacuation drills.
Exception: Actual exiting from windows shall not be required. Opening the window and signaling for help shall be an acceptable alternative.
403.9.4. Group R-3 and R-5 lodging facilities. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for Group R-3 and R-5 bed and breakfast and other transient boarding facilities that are either proprietor or non-proprietor occupied.
403.10. Special uses. Special uses shall comply with the provisions of this section applicable to the type of special use.
403.10.1. Covered and open mall buildings. Covered and open mall buildings shall comply with the requirements of Sections 403.10.1.1 through 403.10.1.6.
403.10.1.1. Malls and mall buildings exceeding 50,000 square feet. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for covered malls exceeding 50,000 square feet (4645 m2) in aggregate floor area and for open mall buildings exceeding 50,000 square feet (4645 m2) in aggregate area within perimeter line.
403.10.1.2. Lease plan. In addition to the requirements of Section 404.2.2, a lease plan that includes the following information shall be prepared for each covered and open mall building:
1. Each occupancy, including identification of tenant.
2. Exits from each tenant space.
3. Fire protection features, including the following:
3.1. Fire department connections.
3.2. Fire command center.
3.3. Smoke management system controls.
3.4. Elevators, elevator machine rooms and controls.
3.5. Hose valve outlets.
3.6. Sprinkler and standpipe control valves.
3.7. Automatic fire-extinguishing system areas.
3.8. Automatic fire detector zones.
3.9. Fire barriers.
403.10.1.3. Lease plan approval. The lease plan shall be submitted to the fire code official for approval, and shall be maintained on site for immediate reference by responding fire service personnel.
403.10.1.4. Lease plan revisions. The lease plans shall be revised annually or as often as necessary to keep them current. Modifications or changes in tenants or occupancies shall not be made without prior approval of the fire code official and building official.
403.10.1.5. Tenant identification. Tenant identification shall be provided for secondary exits from occupied tenant spaces that lead to an exit corridor or directly to the exterior of the building. Tenant identification shall be posted on the exterior side of the exit or exit access door and shall identify the business name or address, or both, using plainly legible letters and numbers that contrast with their background.
Exception: Tenant identification is not required for anchor stores.
403.10.1.6. Unoccupied tenant spaces. The fire safety and evacuation plan shall provide for compliance with the requirements for unoccupied tenant spaces in Section 311.
403.10.2. High-rise buildings. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for high-rise buildings.
403.10.3. Underground buildings. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for underground buildings.
403.10.4. SRCF. An approved fire safety and evacuation plan in accordance with Section 404 shall be prepared and maintained for SRCFs.
403.11. Special requirements for public safety. Special requirements for public safety shall be as required in this section.
403.11.1. Fire watch personnel. When, in the opinion of the fire code official, it is essential for public safety in a place of assembly or any other place where people congregate, because of the number of persons or the nature of the performance, exhibition, display, contest or activity, the owner, agent or lessee shall provide one or more fire watch personnel, as required and approved. Fire watch personnel shall comply with Sections 403.11.1.1 and 403.11.1.2.
403.11.1.1. Duty times. Fire watch personnel shall remain on duty during the times places requiring a fire watch are open to the public, or when an activity requiring a fire watch is being conducted.
403.11.1.2. Duties. On-duty fire watch personnel shall have the following duties:
1. Keep diligent watch for fires, obstructions to means of egress and other hazards.
2. Take prompt measures for remediation of hazards and extinguishment of fires that occur.
3. Take prompt measures to assist in the evacuation of the public from the structures.
403.11.2. Public safety plan for gatherings. In other than Group A or E occupancies, where the fire code official determines that an indoor or outdoor gathering of persons has an adverse impact on public safety through diminished access to buildings, structures, fire hydrants and fire apparatus access roads or where such gatherings adversely affect public safety services of any kind, the fire code official shall have the authority to order the development of or prescribe a public safety plan that provides an approved level of public safety and addresses the following items:
1. Emergency vehicle ingress and egress.
2. Fire protection.
3. Emergency egress or escape routes.
4. Emergency medical services.
5. Public assembly areas.
6. The directing of both attendees and vehicles, including the parking of vehicles.
7. Vendor and food concession distribution.
8. The need for the presence of law enforcement.
9. The need for fire and emergency medical services personnel.
403.11.3. Crowd managers for gatherings exceeding 1,000 people. Where facilities or events involve a gathering of more than 1,000 people, crowd managers shall be provided in accordance with Section 403.11.3.1.
403.11.3.1. Number of crowd managers. The minimum number of crowd managers shall be established at a ratio of one crowd manager for every 250 persons.
Exception: Where approved by the fire code official, the number of crowd managers shall be permitted to be reduced where the facility is equipped throughout with an approved automatic sprinkler system or based upon the nature of the event.
403.11.3.2. Duties. The duties of crowd managers shall include, but not be limited to:
1. Conduct an inspection of the area of responsibility and identify and address any egress barriers.
2. Conduct an inspection of the area of responsibility and identify and mitigate any fire hazards.
3. Verify compliance with all permit conditions, including those governing pyrotechnics and other special effects.
4. Direct and assist the event attendees in evacuation during an emergency.
5. Assist emergency response personnel where requested.
6. Other duties required by the fire code official.
7. Other duties as specified in the fire safety plan.
403.11.3.3. Training. Training for crowd managers shall be approved.
C. Change Section 404 to read:
Section 404.
Fire Safety, Evacuation and Lockdown Plans.
404.1. General. Where required by Section 403, fire safety, evacuation and lockdown plans shall comply with Sections 404.2 through 404.4.1.
404.2. Contents. Fire safety and evacuation plan contents shall be in accordance with Sections 404.2.1 and 404.2.2.
404.2.1. Fire evacuation plans. Fire evacuation plans shall include the following:
1. Emergency egress or escape routes and whether evacuation of the building is to be complete or, where approved, by selected floors or areas only.
2. Procedures for employees who must remain to operate critical equipment before evacuating.
3. Procedures for assisted rescue for persons unable to use the general means of egress unassisted.
4. Procedures for accounting for employees and occupants after evacuation has been completed.
5. Identification and assignment of personnel responsible for rescue or emergency medical aid.
6. The preferred and any alternative means of notifying occupants of a fire or emergency.
7. The preferred and any alternative means of reporting fires and other emergencies to the fire department or designated emergency response organization.
8. Identification and assignment of personnel who can be contacted for further information or explanation of duties under the plan.
9. A description of the emergency voice/alarm communication system alert tone and preprogrammed voice messages, where provided.
404.2.2. Fire safety plans. Fire safety plans shall include the following:
1. The procedure for reporting a fire or other emergency.
2. The life safety strategy and procedures for notifying, relocating or evacuating occupants, including occupants who need assistance.
3. Site plans indicating the following:
3.1. The occupancy assembly point.
3.2. The locations of fire hydrants.
3.3. The normal routes of fire department vehicle access.
4. Floor plans identifying the locations of the following:
4.1. Exits.
4.2. Primary evacuation routes.
4.3. Secondary evacuation routes.
4.4. Accessible egress routes.
4.5. Areas of refuge.
4.6. Exterior areas for assisted rescue.
4.7. Manual fire alarm boxes.
4.8. Portable fire extinguishers.
4.9. Occupant-use hose stations.
4.10. Fire alarm annunciators and controls.
5. A list of major fire hazards associated with the normal use and occupancy of the premises, including maintenance and housekeeping procedures.
6. Identification and assignment of personnel responsible for maintenance of systems and equipment installed to prevent or control fires.
7. Identification and assignment of personnel responsible for maintenance, housekeeping and controlling fuel hazard sources.
404.2.3. Lockdown plans. Where facilities develop a lockdown plan, the lockdown plan shall be in accordance with Sections 404.2.3.1 through 404.2.3.3.
404.2.3.1. Lockdown plan contents. Lockdown plans shall be approved by the fire code official and shall include the following:
1. Initiation. The plan shall include instructions for reporting an emergency that requires a lockdown.
2. Accountability. The plan shall include accountability procedures for staff to report the presence or absence of occupants.
3. Recall. The plan shall include a prearranged signal for returning to normal activity.
4. Communication and coordination. The plan shall include an approved means of two-way communication between a central location and each secured area.
404.2.3.2. Training frequency. The training frequency shall be included in the lockdown plan. The lockdown drills shall not substitute for any of the fire and evacuation drills required in Section 405.2.
404.2.3.3. Lockdown notification. The method of notifying building occupants of a lockdown shall be included in the plan. The method of notification shall be separate and distinct from the fire alarm signal.
404.3. Maintenance. Fire safety and evacuation plans shall be reviewed or updated annually or as necessitated by changes in staff assignments, occupancy or the physical arrangement of the building.
404.4. Availability. Fire safety and evacuation plans shall be available in the workplace for reference and review by employees, and copies shall be furnished to the fire code official for review upon request.
404.4.1. Distribution. The fire safety and evacuation plans shall be distributed to the tenants and building service employees by the owner or owner's agent. Tenants shall distribute to their employees applicable parts of the fire safety plan affecting the employees' actions in the event of a fire or other emergency. Fire safety and evacuation plans shall be made available by the proprietor of Group R-3 and R-5 bed and breakfast and other transient boarding facilities to transient guests upon their arrival or are present in each transient guest room.
D. Change Section 405.1 to read:
405.1. General. Emergency evacuation drills complying with Sections 405.2 through 405.9 shall be conducted at least annually where fire safety and evacuation plans are required by Section 403 or when required by the fire code official. Drills shall be designed in cooperation with the local authorities.
Exception: Emergency evacuation drills shall not be conducted in school buildings during periods of mandatory testing required by the Virginia Board of Education.
E. Delete the "High-rise buildings" row in Table 405.2; add the following row to Table 405.2, and change footnotes "a," "b," and "d" of Table 405.2 to read:
Group or Occupancy | Frequency | Participation |
SRCF | Monthly | All occupants |
a. In severe climates, the fire code official shall have the authority to modify the emergency evacuation drill frequency. b. Fire and evacuation drills in residential care assisted living facilities shall include complete evacuation of the premises in accordance with Section 403.9.3.6. Where occupants receive habilitation or rehabilitation training, fire prevention and fire safety practices shall be included as part of the training program. d. Applicable to Group R-2 college and university buildings in accordance with Section 403.9.2.1. |
F. Add Section 405.2.1 to read:
405.2.1. High-rise buildings. Fire exit drills shall be conducted annually by building staff personnel or the owner of the building in accordance with the fire safety plan and shall not affect other current occupants.
G. Change Item 4 of Section 405.5 to read:
4. Employees on duty and participating.
H. Change Section 406.1 to read:
406.1. General. Where fire safety and evacuation plans are required by Section 403, employees shall be trained in fire emergency procedures based on plans prepared in accordance with Section 404.
I. Change Section 406.3.3 to read:
406.3.3. Fire safety training. Employees assigned firefighting duties shall be trained to know the locations and proper use of portable fire extinguishers or other manual firefighting equipment and the protective clothing or equipment required for its safe and proper use.
J. Delete Section 406.3.4.
K. Add Section 406.4 to read:
406.4. Emergency lockdown training. Where a facility has a lockdown plan, employees shall be trained on their assigned duties and procedures in the event of an emergency lockdown.
L. Delete Section 408 in its entirety. ]
13VAC5-51-133. IFC Chapter 5. Fire Service Features.
A. [ Change Section 501.2 to read:
501.2. Permits. A permit shall be required as set forth in Section 107.2.
B. ] Delete Section 501.4.
[ B. C. ] Add exceptions to Section 503.1 to read:
Exceptions:
1. Fire apparatus access roads shall be permitted to be provided and maintained in accordance with written policy that establish fire apparatus access road requirements and such requirements shall be identified to the owner or his agent prior to the building official's approval of the building permit.
2. On construction and demolition sites fire apparatus access roads shall be permitted to be provided and maintained in accordance with Section 1410.1 3310.1.
[ C. D. ] Add exception to Section 503.2.1 to read:
Exception: Fire apparatus access roads exclusively serving single family dwelling or townhouse developments that are fully sprinklered as provided for in Sections R313.1 or R313.2 of the International Residential Code shall have an unobstructed width of not less than 18 feet (5486 mm), exclusive of shoulders.
[ D. E. ] Add Section 503.7 to read:
503.7. Fire lanes for existing buildings. The fire code official is authorized to designate public and private fire lanes as deemed necessary for the efficient and effective operation of fire apparatus. Fire lanes shall comply with Sections 503.2 through 503.6.
E. Change the title of Section 506 to read "Key Boxes and Elevator Fire Service Keys."
F. Change Section 506.1 to read:
506.1. Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or firefighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037 and shall contain keys to gain necessary access as required by the fire code official.
Exception: Existing key boxes are not required to be listed in accordance with UL 1037 unless replaced.
G. Add Section 506.3, including all subsections, to read:
506.3. Standardized fire service elevator keys. All buildings with elevators equipped with Phase I emergency recall or Phase II emergency in-car operation, or buildings equipped with fire service access or occupant evacuation elevators shall be equipped to operate with a standardized fire service key approved by the fire code official.
Exception: Where providing a standardized key is not possible due to the existing nonstandard elevator equipment, the owner shall be permitted to place the building's nonstandardized fire service elevator keys in a key box installed in accordance with Section 506.1.
506.3.1. Requirements for standardized fire service keys. Standardized fire service elevator keys shall comply with all of the following:
1. All fire service elevator keys within the jurisdiction shall be uniform and specific for the jurisdiction. Keys shall be cut to a uniform key code.
2. Fire service elevator keys shall be a patent protected design to prevent unauthorized duplication.
3. Fire service elevator keys subject to these rules shall be engraved with the words "DO NOT DUPLICATE."
506.3.2. Access to standardized fire service keys. Access to standardized fire service elevator keys shall be restricted to the following persons or groups:
1. Elevator owners or their authorized agents.
2. Elevator contractors.
3. Elevator inspectors of the jurisdiction.
4. Fire and building code officials of the jurisdiction.
5. The fire department and other emergency response agencies designated by the fire code official and the code official responsible for the enforcement of Part III, Maintenance, of the USBC.
506.3.3. Duplication or distribution of keys. No person may duplicate a standardized fire service elevator key or issue, give, or sell a duplicated key unless in accordance with this code.
506.3.4. Responsibility to provide keys. The building owner shall provide up to three standardized fire service elevator keys, if required by the fire code official, upon installation of a standardized fire service key switch or switches in the building.
H. [ E. F. ] Add Sections 507.3.1 and 507.3.2 to read:
507.3.1. Fire flow requirements for fully sprinklered residential developments. Notwithstanding Section 103.1.2, the fire flow requirements in Table B105.1 of Appendix B of the IFC, as modified by Section 507.3.2, shall be permitted to be used for determining fire flow in single family dwelling and townhouse developments which are fully sprinklered as provided for in Sections R313.1 or R313.2 of the International Residential Code.
507.3.2. Modifications to Table B105.1. The first six rows of columns five and six of Table B105.1 of Appendix B of the IFC shall be modified as shown below for the use of Table B105.1 in Section 507.3.1.
Type 5-B | Fire-flow (gallons per minute) |
0-5000 | 1000 |
5001-7200 | 1250 |
7201-8200 | 1500 |
8201-9500 | 1750 |
9501-11300 | 2000 |
11301-13000 | 2250 |
I. [ F. G. ] Change Section 507.5.1 to read:
507.5.1. Where required. Fire hydrant systems shall be located and installed as directed by the fire department. Fire hydrant systems shall conform to the written standards of the jurisdiction and the fire department.
J. [ G. H. ] Add Section 507.5.1.1 507.5.1.2 to read:
507.5.1.1 507.5.1.2. Fire hydrant requirements for fully sprinklered residential developments. Notwithstanding Section 103.1.2, the number and distribution of fire hydrants in Table C105.1 of Appendix C of the IFC shall be permitted to be used in single family dwelling and townhouse developments which are fully sprinklered as provided for in Sections R313.1 or R313.2 of the International Residential Code, with the spacing and distances of fire hydrants indicated in Table C105.1 increased by 100%.
K. [ H. I. ] Change Section 510 to read:
Section 510.
Maintenance of In-Building Emergency Communication Equipment.
510.1. General. In-building emergency communication equipment shall be maintained in accordance with USBC and the provisions of this section.
510.2. Additional in-building emergency communications installations. If it is determined by the locality that increased amplification of their emergency communication system is needed, the building owner shall allow the locality access as well as provide appropriate space within the building to install and maintain necessary additional communication equipment by the locality. If the building owner denies the locality access or appropriate space, or both, the building owner shall be responsible for the installation and maintenance of these additional systems.
510.3. Field tests. After providing reasonable notice to the owner or their representative, the fire official, police chief, or their agents shall have the right during normal business hours, or other mutually agreed upon time, to enter onto the property to conduct field tests to verify that the required level of radio coverage is present at no cost to the owner.
13VAC5-51-133.5. IFC Chapter 6. Building Services and Systems.
A. [ Change Section 601.2 to read:
601.2. Permits. Permits shall be obtained for refrigeration systems, battery systems and solar photovoltaic power systems as set forth in Section 107.2.
B. ] Add a note to Section 603.7 to read:
Note: The fire code official may request a copy of the latest certificate of inspection from the Virginia Department of Labor and Industry for boilers and pressure vessels subject to such requirements. When the certificate is not available, the fire code official shall notify the Department of Labor and Industry to ensure that the required maintenance and testing is performed in accordance the Virginia Boiler and Pressure Vessel Regulations (16VAC25-50).
[ B. C. ] Add Section 604.6 604.7 to read:
604.6 604.7. Testing of battery powered emergency lights and exit signs. Required emergency lighting utilizing battery powered emergency lights or exit signs, or both, shall be tested annually. The emergency lights and exit signs shall be tested for proper operation for the time period established in the building code in effect when the equipment was installed. Written records of tests shall be retained by the owner of the building for a minimum of two years after the test is conducted and shall be made available to the fire code official upon request.
[ C. D. ] Change Section 605.10.1 to read:
605.10.1. Listed and labeled. Only portable electric space heaters listed and labeled in accordance with UL 1278 shall be used.
[ E. Change Section 607.1 to read:
607.1. Operation. Existing elevators with a travel distance of 25 feet (7620 mm) or more shall comply with the requirements of Section 607.5 and the USBC, Part III, Maintenance.
F. Change Section 609.3.3.3 and add Section 609.3.3.3.1 to read:
609.3.3.3. Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection, and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained for a minimum of three years and be copied to the fire code official upon request.
609.3.3.3.1. Tags. Where a commercial kitchen hood or duct system is cleaned, a tag containing the service provider name, address, telephone number, and date of service shall be provided in a conspicuous location. Prior tags shall be covered or removed.
Exception: Where records required by Section 609.3.3.3 are maintained on the premises.
13VAC5-51-133.8. IFC Chapter 7. Fire-Resistance-Rated Construction.
Change Section 704.1 to read:
704.1. Enclosure. New floor openings in existing buildings shall comply with the International Building Code. ]
13VAC5-51-135. IFC Chapter 9. Fire Protection Systems.
A. [ Change Section 901.3 to read:
901.3. Permits. Permits shall be required as set forth in Section 107.2.
B. ] Change Section 901.4.2 to read:
901.4.2. Nonrequired fire protection systems. Nonrequired fire protection systems shall be maintained to function as originally installed. If any such systems are to be reduced in function or discontinued, approval shall be obtained from the building official in accordance with Section 103.8.1 of Part I of the USBC.
[ B. C. ] Delete Section 901.4.3 901.4.4.
[ C. D. ] Change Section 901.6 to read:
901.6. Inspection, testing and maintenance. To the extent that equipment, systems, devices, and safeguards, such as fire detection, alarm and extinguishing systems, which were provided and approved by the building official when constructed, shall be maintained in an operative condition at all times. And where such equipment, systems, devices, and safeguards are found not to be in an operative condition, the fire official shall order all such equipment to be rendered safe in accordance with the USBC.
[ D. E. ] Add Section 901.10 901.11 to read:
901.10 901.11. Defective equipment. When the fire official determines through investigation or testing or reports by a nationally recognized testing agency that specific, required water sprinkler or water-spray extinguishing equipment has been identified as failing to perform or operate through not less than 30 randomly selected sprinkler heads at four or more building sites anywhere in the nation, the fire official shall order all such equipment to be rendered safe.
E. Change the following definition in Section 902 to read:
Automatic fire-extinguishing system. An approved system of devices and equipment which automatically detects a fire and discharges an approved fire-extinguishing agent onto or in the area of a fire. Such system shall include an automatic sprinkler system, unless otherwise expressly stated.
[ F. Change Section 903.6 to read:
903.6. Where required in existing buildings and structures. An automatic sprinkler system shall be provided in existing buildings and structures in accordance with Section 102.7 of this code.
G. Delete Section 905.11. ]
F. [ E. H. ] Change item Item 1 in Section 906.1 to read:
1. In Group A, B, E, F, H, I, M, R-1, R-4 and S occupancies.
Exception Exceptions:
1. In Groups A, B, and E occupancies equipped throughout with quick response sprinklers, portable fire extinguishers shall be required only in locations specified in Items 2 through 6.
2. In Group I-3 occupancies, portable fire extinguishers shall be permitted to be located at staff locations and the access to such extinguishers shall be permitted to be locked.
[ G. I. ] Add a note to Section 906.1 to read:
Note: In existing buildings, whether fire extinguishers are needed is determined by the USBC or other code in effect when such buildings were constructed.
[ J. Change Section 907.1 to read:
907.1. General. This section covers the application, installation, performance and maintenance of fire alarm systems and their components in new and existing buildings and structures. The requirements of Section 907.2 are applicable to new buildings and structures.
H. K. ] Change Section 907.9.2 907.8.2 to read:
907.9.2 907.8.2. Testing. Testing shall be performed in accordance with the schedules in Chapter 10 of NFPA 72 or more frequently where required by the fire code official. Where automatic testing is performed at least weekly by a remotely monitored fire alarm control unit specifically listed for the application, the manual testing frequency shall be permitted to be extended to annual. In Group R-1 occupancies, battery-powered single station smoke detectors shall be tested and inspected at one-month intervals.
Exception: Devices or equipment that are inaccessible for safety considerations shall be tested during scheduled shutdowns where approved by the fire code official, but not less than every 18 months.
[ I. L. ] Change Section 907.9.5 907.8.5 to read:
907.9.5 907.8.5. Maintenance, inspection and testing. The building owner shall be responsible for maintaining the fire and life safety systems in an operable condition at all times. Service personnel shall meet the qualification requirements of NFPA 72 for maintaining, inspecting and testing such systems. A written record shall be maintained and shall be made available to the fire code official. In addition to all applicable information contained in Figure 10.6.2.3 of NFPA 72, the written record of inspections, testing and maintenance shall contain the following minimum information:
1. Date, name and address of property.
2. Name of person performing inspection, maintenance and tests, or combination thereof, and affiliation, business address and telephone number.
3. Name, address and representative of approving agency or agencies.
4. Test frequency.
5. Designation of the detector or detectors tested (for example, "Test performed in accordance with Section _______.").
6. Physical location (for example, "Heat detector in main kitchen; horn-strobe in Room 115.") and a list of all initiating and notification devices and appliances tested.
7. Functional list of detectors and required sequence of operations.
8. Check of all smoke detectors.
9. Loop resistance for all fixed-temperature, line-type detectors.
10. Other tests as required by either the equipment manufacturer's published instructions or the authority having jurisdiction.
11. Signature of tester and approved authority representative.
12. Disposition of problems identified during test (examples, "Owner notified," "Problem corrected or successfully retested, or both," "Device abandoned in place.").
[ J. M. Delete Section 907.9.
N. ] Add Change Section 908.7 to read:
908.7. Carbon monoxide alarms. Carbon monoxide alarms shall be maintained as approved.
[ K. O. ] Delete Section 908.7.1.
[ 13VAC5-51-135.5. IFC Chapter 10. Means of Egress.
A. Add Section 1001.3 to read:
1001.3. Overcrowding. Overcrowding, admittance of any person beyond the approved occupant load established by the USBC or other building code under which the building was constructed, or obstructing aisles, passageways, or any part of the means of egress shall not be allowed. The fire code official, upon finding any condition that constitutes a life safety hazard, shall be authorized to cause the event to be stopped until such condition or obstruction is corrected.
B. Change Section 1029.4 to read:
1029.4. Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates, or similar devices are permitted to be placed over emergency escape and rescue openings provided (i) the minimum net clear opening size complies with Section 1029.2, (ii) such devices shall be releasable or removable from the inside without the use of a key, tool, or force greater than that which is required for normal operation of the escape and rescue opening, and (iii) where smoke alarms are installed in accordance with Section 907.2.11 and approved by the building official regardless of the valuation of the alteration. ]
13VAC5-51-138. IFC Chapter 11. Construction Requirements for Existing Buildings.
Delete Chapter 11 in its entirety.
[ 13VAC5-51-138.4. IFC Chapter 20. Aviation Facilities.
Change Section 2001.3 to read:
2001.3. Permits. For permits to operate aircraft-refueling vehicles, application of flammable or combustible finishes and hot work, see Section 107.2.
13VAC5-51-138.8. IFC Chapter 21. Dry Cleaning.
Change Section 2101.2 to read:
2101.2. Permit required. Permits shall be required as set forth in Section 107.2.
13VAC5-51-139. IFC Chapter 22. Combustible Dust-Producing Operations.
Change Section 2201.2 to read:
2201.2. Permits. Permits shall be required for combustible dust-producing operations as set forth in Section 107.2. ]
13VAC5-51-140. IFC Chapter 22 23. Service Stations Motor Fuel-Dispensing Facilities and Repair Garages.
A. [ Change Section 2301.2 to read:
2301.2. Permits. Permits shall be required as set forth in Section 107.2.
B. ] Change Section 2205.4 2305.4 to read:
2205.4 2305.4. Sources of ignition. Smoking and open flames shall be prohibited within 20 feet (6096 mm) of a fuel dispensing device. The engines of vehicles being fueled shall be shut off during fueling. Electrical equipment shall be in accordance with NFPA 70.
[ B. C. ] Change Section 2206.2.1.1 2306.2.1.1 to read:
2206.2.1.1 2306.2.1.1. Inventory control and leak detection for underground tanks. Accurate inventory records shall be maintained on underground fuel storage tanks for indication of possible leakage from tanks and piping. The records shall be kept at the premises or made available for inspection by the fire official within 24 hours of a written or verbal request and shall include records for each tank. Where there is more than one system consisting of tanks serving separate pumps or dispensers for a product, the inventory record shall be maintained separately for each tank system.
Owners and operators of underground fuel storage tanks shall provide release detection for tanks and piping that routinely contain flammable and combustible liquids in accordance with one of the following methods:
1. Monthly inventory control to detect a release of at least 1.0% of flow-through plus 130 gallons.
2. Manual tank gauging for tanks with 2,000 gallon capacity or less when measurements are taken at the beginning and ending of a 36-hour to 58-hour period during which no liquid is added to or removed from the tank.
3. Tank tightness testing capable of detecting a 0.1 gallon per hour leak rate.
4. Automatic tank gauging that tests for loss of liquid.
5. Vapor monitoring for vapors within the soil of the tank field.
6. Groundwater monitoring when the groundwater is never more than 20 feet from the ground surface.
7. Interstitial monitoring between the underground tank and a secondary barrier immediately around or beneath the tank.
8. Other approved methods that have been demonstrated to be as effective in detecting a leak as the methods listed above.
A consistent or accidental loss of product shall be immediately reported to the fire official.
[ D. Change Section 2306.8.1 to read:
2306.8.1. Listed. Dispensers shall be listed in accordance with UL 87A. Hoses, nozzles, breakaway fittings, swivels, flexible connectors or dispenser emergency shutoff valves, vapor recovery systems, leak detection devices, and pumps used in alcohol-blended fuel-dispensing systems shall be listed for the specific purpose.
E. Add Section 2306.8.6 to read:
2306.8.6. Compatibility. Dispensers shall only be used with the fuels for which they have been listed, which are marked on the product. Field installed components including hose assemblies, breakaway couplings, swivel connectors, and hose nozzle valves shall be provided in accordance with the listing and the marking on the unit.
13VAC5-51-140.5. IFC Chapter 24. Flammable Finishes.
Change Section 2401.3 to read:
2401.3. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-141. IFC Chapter 25. Fruit and Crop Ripening.
Change Section 2501.2 to read:
2501.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-141.5. IFC Chapter 26. Fumigation and Insecticidal Fogging.
Change Section 2601.2 to read:
2601.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-142. IFC Chapter 27. Semiconductor Fabrication Facilities.
Change Section 2701.5 to read:
2701.5. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-142.5. IFC Chapter 28. Lumber Yards and Woodworking Facilities.
Change Section 2801.2 to read:
2801.2. Permit. Permits shall be required as set forth in Section 107.2.
13VAC5-51-143.5. IFC Chapter 29. Manufacture of Organic Coatings.
Change Section 2901.2 to read:
2901.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-144. IFC Chapter 30. Industrial Ovens.
Change Section 3001.2 to read:
3001.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-144.2. IFC Chapter 31. Tents and Other Membrane Structures.
Change Section 3103.4 to read:
3103.4. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-144.4. IFC Chapter 32. High-Piled Combustible Storage.
Change Section 3201.2 to read:
3201.2. Permits. A permit shall be required as set forth in Section 107.2.
13VAC5-51-144.6. IFC Chapter 34. Tire Rebuilding and Tire Storage.
A. Change Section 3401.2 to read:
3401.2. Permit required. Permits shall be required as set forth in Section 107.2.
B. Change Section 3406.1 to read:
3406.1. Required access. New and existing tire storage yards shall be provided with fire apparatus access roads in accordance with Section 503 and Section 3406.2. ]
13VAC5-51-145. IFC Chapter 27 50. Hazardous Materials - General Provisions.
A. [ Change Section 5001.5 to read:
5001.5. Permits. Permits shall be required as set forth in Section 107.2.
B. ] Add the following language to the end of Section 2701.5.1 5001.5.1 to read:
The HMMP shall be maintained onsite for use by emergency responders, and shall be updated not less than annually.
[ B. C. ] Add the following language to the end of Section 2701.5.2 5001.5.2 to read:
The HMIS shall be maintained onsite or readily available through another means where approved by the fire code official for use by temporary responders, and shall be updated not less than annually.
[ C. D. ] Add Sections 2701.5.3, 2701.5.3.1 5001.5.3, 5001.5.3.1, and 2701.5.3.2 5001.5.3.2 to read:
2701.5.3 5001.5.3. Repository container. When a HMMP or HMIS is required, the owner or operator shall provide a repository container (lock box) or other approved means for the storage of items required in Sections 2701.5.1 5001.5.1 and 2701.5.2 5001.5.2 so as to be readily available to emergency response personnel.
2701.5.3.1 5001.5.3.1. Location and identification. The repository container (lock box) shall be located, installed and identified in an approved manner.
2701.5.3.2 5001.5.3.2. Keying. All repository containers (lock boxes) shall be keyed as required by the fire code official.
[ E. Change the "Consumer fireworks" row and add a new "Permissible fireworks" row to Table 5003.1.1(1) to read:
Consumer fireworks | 1.4G | H-3 | 125e,l | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Permissible fireworks | 1.4G | H-3 | 125d,e,l | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
D. F. ] Change Section 2703.3.1.4 5003.3.1.4 to read:
2703.3.1.4 5003.3.1.4. Responsibility for cleanup. The person, firm or corporation responsible for an unauthorized discharge shall institute and complete all actions necessary to remedy the effects of such unauthorized discharge, whether sudden or gradual, at no cost to the jurisdiction. The fire code official may require records and receipts to verify cleanup and proper disposal of unauthorized discharges. When deemed necessary by the fire code official, cleanup may be initiated by the fire department or by an authorized individual or firm. Costs associated with such cleanup shall be borne by the owner, operator or other person responsible for the unauthorized discharge.
[ 13VAC5-51-145.5. IFC Chapter 51. Aerosols.
Change Section 5101.2 to read:
5101.2. Permit required. Permits shall be required as set forth in Section 107.2.
13VAC5-51-146. IFC Chapter 52. Combustible Fibers.
Change Section 5201.3 to read:
5201.3. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-146.5. IFC Chapter 53. Compressed Gases.
Change Section 5301.2 to read:
5301.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-147. IFC Chapter 54. Corrosive Materials.
Change Section 5401.2 to read:
5401.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-147.5. IFC Chapter 55. Cryogenic Fluids.
Change Section 5501.2 to read:
5501.2. Permits. Permits shall be required as set forth in Section 107.2. ]
13VAC5-51-150. IFC Chapter 33 56. Explosives and Fireworks.
A. Change exception 4 in Section 3301.1 5601.1 to read:
4. The possession, storage, and use of not more than 15 pounds (6.81 kg) of commercially manufactured sporting black powder, 20 pounds (9 kg) of smokeless powder and any amount of small arms primers for hand loading of small arms ammunition for personal consumption.
B. Add exceptions 10, 11 and 12 to Section 3301.1 5601.1 to read:
10. The storage, handling, or use of explosives or blasting agents pursuant to the provisions of Title 45.1 of the Code of Virginia.
11. The display of small arms primers in Group M when in the original manufacturer's packaging.
12. The possession, storage and use of not more than 50 pounds (23 kg) of commercially manufactured sporting black powder, 100 pounds (45 kg) of smokeless powder, and small arms primers for hand loading of small arms ammunition for personal consumption in Group R-3 or R-5, or 200 pounds (91 kg) of smokeless powder when stored in the manufacturer's original containers in detached Group U structures at least 10 feet (3048 mm) from inhabited buildings and are accessory to Group R-3 or R-5.
C. Change exception 4 in Section 3301.1.3 5601.1.3 to read:
4. The possession, storage, sale, handling and use of permissible fireworks where allowed by applicable local or state laws, ordinances and regulations provided such fireworks comply with CPSC 16 CFR, Parts 1500-1507, and DOTn 49 CFR, Parts 100-178, for consumer fireworks.
D. Add exception 5 to Section 3301.1.3 5601.1.3 to read:
5. The sale or use of materials or equipment when such materials or equipment is used or to be used by any person for signaling or other emergency use in the operation of any boat, railroad train or other vehicle for the transportation of persons or property.
E. Change entire Section 3301.2 5601.2 to read:
3301.2 5601.2. Permit required. Permits shall be required as set forth in Section 107.2 and regulated in accordance with this section. The manufacture, storage, possession, sale and use of fireworks or explosives shall not take place without first applying for and obtaining a permit.
3301.2.1 5601.2.1. Residential uses. No person shall keep or store, nor shall any permit be issued to keep, possess or store, any fireworks or explosives at any place of habitation, or within 100 feet (30,480 mm) thereof.
Exception: Storage of smokeless propellant, black powder, and small arms primers for personal use and not for resale in accordance with Section 3306 5606.
3301.2.2 5601.2.2. Sale and retail display. Except for the Armed Forces of the United States, Coast Guard, National Guard, federal, state and local regulatory, law enforcement and fire agencies acting in their official capacities, explosives shall not be sold, given, delivered or transferred to any person or company not in possession of a valid permit. The holder of a permit to sell explosives shall make a record of all transactions involving explosives in conformance with Section 3303.2 5603.2 and include the signature of any receiver of the explosives. No person shall construct a retail display nor offer for sale explosives, explosive materials, or fireworks upon highways, sidewalks, public property, or in assembly or educational occupancies.
3301.2.3 5601.2.3. Permit restrictions. The fire official is authorized to limit the quantity of explosives, explosive materials, or fireworks permitted at a given location. No person, possessing a permit for storage of explosives at any place, shall keep or store an amount greater than authorized in such permit. Only the kind of explosive specified in such a permit shall be kept or stored.
3301.2.3.1 5601.2.3.1. Permit applicants. As a condition of a permit as provided for in Section 107.5, the fire official shall not issue a permit to manufacture, store, handle, use or sell explosives or blasting agents to any applicant who has not provided on the permit application the name and signature of a designated individual as representing the applicant. When, as provided for in Section 107.2 or 107.6, a permit is required to conduct a fireworks display, as a condition of permit as provided for in Section 107.5, the fire official shall not issue a permit to design, setup or conduct a fireworks display to any applicant who has not provided on the permit application the name and signature of a designated individual as representing the applicant.
If the applicant's designated individual changes or becomes no longer qualified to represent the applicant as responsible management or designated individual, the applicant shall notify the fire official who issued the permit on the change of status of the designated individual. The notice is to be made prior to the use of any explosives or conducting a fireworks display but in no case shall the notification occur more than seven days after the change of status and shall provide the name of another designated individual. The fire official may revoke or require the reissuance of a permit based on a change of permit conditions or status or inability to provide another designated individual.
3301.2.3.1.1 5601.2.3.1.1. BCC: The SFMO shall process all applications for a BCC for compliance with § 27-97.2 of the Code of Virginia and will be the sole provider of a BCC. Using forms provided by the SFMO, a [ BBC BCC ] may be applied for and issued to any person who submits to the completion of a background investigation by providing fingerprints and personal descriptive information to the SFMO. The SFMO shall forward the fingerprints and personal descriptive information to the Central Criminal Records Exchange for submission to the Federal Bureau of Investigation for the purpose of obtaining a national criminal history records check regarding such applicant.
3301.2.3.1.2 5601.2.3.1.2. Issuance of a background clearance card BCC: The issuance of a background clearance card BCC shall be denied if the applicant or designated person representing an applicant has been convicted of any felony, whether such conviction occurred under the laws of the Commonwealth, or any other state, the District of Columbia, the United States or any territory thereof, unless his civil rights have been restored by the Governor or other appropriate authority.
3301.2.3.1.3 5601.2.3.1.3. Fee for background clearance card BCC: The fee for obtaining or renewing a background clearance card BCC from the SFMO shall be $150 plus any additional fees charged by other agencies for fingerprinting and for obtaining a national criminal history record check through the Central Criminal Records Exchange to the Federal Bureau of Investigation.
3301.2.3.1.4 5601.2.3.1.4. Revocation of a background clearance card BCC: After issuance of a background clearance card BCC, subsequent conviction of a felony will be grounds for immediate revocation of a background clearance card BCC, whether such conviction occurred under the laws of the Commonwealth, or any other state, the District of Columbia, the United States or any territory thereof. The card BCC shall be returned to the SFMO immediately. An individual may reapply for his background clearance card BCC if his civil rights have been restored by the Governor or other appropriate authority.
3301.2.4 5601.2.4. Financial responsibility. Before a permit is issued, as required by Section 3301.2 5601.2, the applicant shall file with the jurisdiction a corporate surety bond in the principal sum of $500,000 or a public liability insurance policy for the same amount, for the purpose of the payment of all damages to persons or property which arise from, or are caused by, the conduct of any act authorized by the permit upon which any judicial judgment results. The legal department of the jurisdiction may specify a greater amount when conditions at the location of use indicate a greater amount is required. Government entities shall be exempt from this bond requirement.
3301.2.4.1 5601.2.4.1. Blasting. Before approval to do blasting is issued, the applicant for approval shall file a bond or submit a certificate of insurance in such form, amount, and coverage as determined by the legal department of the jurisdiction to be adequate in each case to indemnify the jurisdiction against any and all damages arising from permitted blasting but in no case shall the value of the coverage be less than $500,000 $1,000,000.
Exception: Filing a bond or submitting a certificate of liability insurance is not required for blasting on real estate parcels of five or more acres conforming to the definition of "real estate devoted to agricultural use" or "real estate devoted to horticultural use" in § 58.1-3230 of the Code of Virginia and conducted by the owner of such real estate.
3301.2.4.2 5601.2.4.2. Fireworks display. The permit holder shall furnish a bond or certificate of insurance in an amount deemed adequate by the legal department of the jurisdiction for the payment of all potential damages to a person or persons or to property by reason of the permitted display, and arising from any acts of the permit holder, the agent, employees or subcontractors, but in no case shall the value of the coverage be less than $500,000 $1,000,000.
F. Change entire Section 3301.4 5601.4 to read:
3301.4 5601.4. Qualifications. Persons in charge of magazines, blasting, fireworks display, or pyrotechnic special effect operations shall not be under the influence of alcohol or drugs which impair sensory or motor skills, shall be at least 21 years of age and possess knowledge of all safety precautions related to the storage, handling or use of explosives, explosive materials or fireworks.
3301.4.1 5601.4.1. Certification of blasters and pyrotechnicians. Certificates as a restricted blaster, unrestricted blaster or pyrotechnician will be issued upon proof of successful completion of an examination approved by the SFMO commensurate to the certification sought and completion of a background investigation for compliance with § 27-97.2 of the Code of Virginia. The applicant for certification shall submit proof to the SFMO of the following experience:
1. For certification as a restricted blaster, at least one year under direct supervision by a certified unrestricted blaster, certified restricted blaster or other person(s) approved by the SFMO.
2. For certification as an unrestricted blaster, at least one year under direct supervision by a certified unrestricted blaster or other person or persons approved by the SFMO.
3. For certification as a pyrotechnician, aerial, or pyrotechnician, proximate, applicant was in responsible charge of or has assisted in the documented design, setup and conducting of a fireworks display on at least six occasions within the 24 months immediately preceding the application for certification.
The SFMO shall process all certification applicants for compliance with § 27-97.2 of the Code of Virginia and will be the sole provider of blaster and pyrotechnician certifications.
Exception: The use of explosives by the owner of real estate parcels of five or more acres conforming to the definition of "real estate devoted to agricultural use" or "real estate devoted to horticultural use" in § 58.1-3230 of the Code of Virginia when blasting on such real estate.
3301.4.2 5601.4.2. Certification issuance. The issuance of a certification as a blaster or pyrotechnician shall be denied if the applicant has (i) been convicted of any felony, whether such conviction occurred under the laws of the Commonwealth, or any other state, the District of Columbia, the United States or any territory thereof, unless his civil rights have been restored by the Governor or other appropriate authority, (ii) has not provided acceptable proof or evidence of the experience required in Section 3301.4.1 5601.4.1, or (iii) has not provided acceptable proof or evidence of the continued training or education required in Section 3301.4.5 5601.4.5.
3301.4.3 5601.4.3. Fee for certification. The fee for obtaining or renewing a blaster or pyrotechnician certificate from the SFMO shall be $150 plus any additional fees charged by other agencies for fingerprinting and for obtaining a national criminal history record check through the Central Criminal Records Exchange to the Federal Bureau of Investigation.
[ 5601.4.3.1. Fee for replacement certificate. A written request for a replacement blaster or pyrotechnician certificate shall be accompanied by the payment of an administrative fee in the amount of $20 made payable to the Treasurer of Virginia. Verbal requests shall not be accepted. ]
3301.4.4 5601.4.4. Revocation of a blaster or pyrotechnician certification. After issuance of a blaster or pyrotechnician certification, subsequent conviction of a felony will be grounds for immediate revocation of a blaster or pyrotechnician certification, whether such conviction occurred under the laws of the Commonwealth, or any other state, the District of Columbia, the United States or any territory thereof. The certification shall be returned to the SFMO immediately. An individual may subsequently reapply for his blaster or pyrotechnician certification if his civil rights have been restored by the Governor or other appropriate authority.
3301.4.5 5601.4.5. Expiration and renewal of a BCC, or blaster or pyrotechnician certification. A certificate for an unrestricted blaster, restricted blaster or pyrotechnician shall be valid for three years from the date of issuance. A BCC shall be valid for three years from the date of issuance. Renewal of the unrestricted blaster certificate will be issued upon proof of at least 16 accumulated hours of continued training or education in the use of explosives within three consecutive years and a background investigation for compliance with § 27-97.2 of the Code of Virginia. Renewal of the restricted blaster certificate will be issued upon proof of at least eight accumulated hours of continued training or education in the use of explosives within three consecutive years and a background investigation for compliance with § 27-97.2 of the Code of Virginia. Renewal of the pyrotechnician certificate will be issued upon proof of at least 12 accumulated hours of continued training or education in the subject areas of explosives storage; the design, setup or conduct of a fireworks display within three consecutive years; and a background investigation for compliance with § 27-97.2 of the Code of Virginia. The continued training or education required for renewal of a blaster or pyrotechnician certificate shall be obtained during the three years immediately prior to the certificate's published expiration date. Failure to renew a blaster or pyrotechnician certificate in accordance with this section shall cause an individual to obtain another blaster or pyrotechnician certificate upon compliance with Section 3301.4.1 5601.4.1 to continue engaging in the unsupervised use of explosives or conducting a fireworks display.
[ 5601.4.6. Denial, suspension or revocation of a certificate. If issuance or renewal of a blaster or pyrotechnician certificate is denied, or upon the filing of a complaint against an applicant or certificate holder for non-performance, or performance in violation of the SFPC and the appropriate referenced NFPA 495, 1123 or 1126 standards, the State Fire Marshal may convene a three member panel to hear the particulars of the complaint or denial. The three member panel will be comprised of the following persons:
1. A Virginia certified fire official, excluding any person certified as a blaster or pyrotechnician, or who is on the staff of the SFMO.
2. A Virginia certified blaster or pyrotechnician whose certification is the same as that of the person to whom a complaint is lodged, and who is not associated in any way with the person against whom a complaint is lodged and whose work or employer is geographically remote, as much as practically possible, from the person to whom a complaint is lodged.
3. A member of the general public who does not have a vested financial interest in conducting a fireworks display, or the manufacture, sale, storage, or use of explosives.
Upon the State Fire Marshal convening such panel, the hearing is to commence within 60 calendar days of the filing of the complaint or denial. The three-member panel is to hear the complaint and render a written recommendation to the State Fire Marshal for certificate issuance, no action, revocation, or suspension of a certificate for a period not to exceed six months. Notwithstanding the discretionary decision and action to convene such panel, the State Fire Marshal reserves the authority to choose an action that may be contrary to the panel's recommendation. A written decision of the State Fire Marshal is to be delivered to the party within 14 days of the hearing's conclusion. If the certificate is denied, revoked, or suspended by the SFMO, in accordance with Section 112.9, the party may file an appeal with the TRB. The party's appeal to TRB must be filed within 14 calendar days of the receipt of the State Fire Marshal's written decision to deny, revoke, or suspend. The denial, revocation, or suspension of a license is independent of any criminal proceedings that may be initiated by any state or local authority.
5601.4.6.1. Replacement of revoked certificate. Any person whose certificate as a pyrotechnician or blaster was revoked upon cause may apply for certification as a pyrotechnician or blaster six months or more from the date of the revocation and upon compliance with Section 5601.4.1. All elements of Section 5601.4.1 are required to be obtained and dated after the date of revocation.
5601.4.6.2. Return of suspended certificate. Any certificate that was suspended upon cause will be reinstated at the end of the suspension period without change to its expiration date. ]
G. Change Section 3301.7 5601.7 to read:
3301.7 5601.7. Seizure. The fire official is authorized to remove or cause to be removed or disposed of in an approved manner, at the expense of the owner, fireworks offered or exposed for sale, stored, possessed or used in violation of this chapter.
H. Add the following to the list of definitions to in Section 3302.1 to read 5602.1:
Background clearance card (BCC). An identification card issued to an individual who is not a certified blaster or pyrotechnician and is responsible management or an employee of a company, corporation, firm or other entity, solely for the purpose of submitting an application to the fire official for a permit to manufacture, use, handle, store, or sell explosive materials; or conduct a fireworks display. A person to whom a BCC has been issued can fulfill the role of a designated individual on an application for a permit to manufacture, use, handle, store, or sell explosive materials; or on an application for a permit to design, setup and conduct a fireworks display.
Blaster, restricted. Any person engaging in the use of explosives or blasting agents utilizing five pounds (2.25 kg) or less per blasting operation and using instantaneous detonators. A certified restricted blaster can fulfill the role of a designated individual on an application for permit to manufacture, use, handle, store, or sell explosive materials.
Blaster, unrestricted. Any person engaging in the use of explosives or blasting agents without limit to the amount of explosives or blasting agents or type of detonator. A certified unrestricted blaster can fulfill the role of a designated individual on an application for permit to manufacture, use, handle, store, or sell explosive materials.
Design. For the purposes of a fireworks display, either inside a building or structure or outdoors, it shall mean the pyrotechnician who will be in attendance and makes the final artistic determination for the placement of fireworks and ground display pieces suitable for the display site.
Designated individual. A person who is in possession of a BCC issued by the SFMO, certified by the SFMO as a pyrotechnician, or a restricted or unrestricted blaster, any of whom are responsible for ensuring compliance with state law and regulations relating to blasting agents and explosives and applying for explosives or firework permits; is at least 21 years of age; and demonstrates the capability to effectively communicate safety messages verbally and in writing in the English language.
Fireworks.
Fireworks, 1.4G.
Fireworks, 1.3G.
Permissible fireworks. Any sparklers, fountains, Pharaoh's serpents, caps for pistols, or pinwheels commonly known as whirligigs or spinning jennies.
Pyrotechnician (fireworks operator). Any person supervising or engaged in the design, setup or conducting of any fireworks display, either inside a building or outdoors. A certified pyrotechnician can fulfill the role of a designated individual on an application for a permit for a fireworks display.
Pyrotechnician, aerial. A person supervising or engaged in the design, setup or conducting of a outdoor aerial fireworks display performed in accordance with the regulations as set forth in this code and NFPA 1123, a referenced standard for fireworks displays.
Pyrotechnician, proximate. A person supervising or engaged in the design, setup or conducting of a fireworks display, either inside a building or outdoors, performed in accordance with the regulations as set forth in this code and NFPA 1126, a referenced standard for the use of pyrotechnics before a proximate audience.
Responsible management. A person who is any of the following:
1. The sole proprietor of a sole proprietorship.
2. The partners of a general partnership.
3. The managing partners of a limited partnership.
4. The officers of a corporation.
5. The managers of a limited liability company.
6. The officers or directors of an association, or both.
7. Individuals in other business entities recognized under the laws of the Commonwealth as having a fiduciary responsibility to the firm.
Smokeless propellants.
Sole proprietor. A person or individual, not a corporation, who is trading under his own name or under an assumed or fictitious name pursuant to the provisions of § 59.1-69 through 59.1-76 of the Code of Virginia.
I. Change the following definitions in Section 3302.1 to read:
Fireworks. Any firecracker, torpedo, skyrocket, or other substance or object, of whatever form or construction, that contains any explosive or inflammable compound or substance, and is intended, or commonly known, as fireworks and that explodes, rises into the air or travels laterally, or fires projectiles into the air. Fireworks shall not include automobile flares, paper caps containing not more than an average of 0.25 grain (16 mg) of explosive content per cap or toy pistols, toy canes, toy guns or other devices utilizing such caps and items commonly known as party poppers, pop rocks and snap-n-pops. Fireworks may be further delineated and referred to as:
Fireworks, 1.4G. (Formerly known as Class C, Common Fireworks.) Small fireworks devices containing restricted amounts of pyrotechnic composition designed primarily to produce visible or audible effects by combustion. Such 1.4G fireworks that comply with the construction, chemical composition, and labeling regulations of the DOTn for Fireworks, UN 0336, and the U.S. Consumer Product Safety Commission as set forth in CPSC 16 CFR: Parts 1500 and 1507, are not explosive materials for the purpose of this code.
Fireworks, 1.3G. (Formerly Class B, Special Fireworks.) Large fireworks devices, which are explosive materials, intended for use in fireworks displays and designed to produce audible or visible effects by combustion, deflagration, or detonation. Such 1.3G fireworks include, but are not limited to, firecrackers containing more than 130 milligrams (2 grains) of explosive composition, aerial shells containing more than 40 grams of pyrotechnic composition, and other display pieces that exceed the limits for classification as 1.4G fireworks. Such 1.3G fireworks are also described as Fireworks, UN0335 by the DOTn.
Smokeless propellants. Solid propellants, commonly referred to as smokeless powders or any propellant classified by DOTn as a smokeless propellant in accordance with "NA3178, Smokeless Powder for Small Arms," used in small arms ammunition, firearms, cannons, rockets, propellant-actuated devices, and similar articles.
[ I. Change Section 5603.4 to read:
5603.4. Accidents. Accidents involving the use of explosives, explosive materials, and fireworks, which result in injuries or property damage, shall be immediately reported by the permit holder to the fire code official and State Fire Marshal.
J. I ] Change Section 3305.1 5605.1 to read:
3305.1 5605.1. General. The manufacture, assembly and testing of explosives, ammunition, blasting agents and fireworks shall comply with the requirements of this section, Title 59.1, Chapter 11 of the Code of Virginia, and NFPA 495 or NFPA 1124.
Exceptions:
1. The hand loading of small arms ammunition prepared for personal use and not offered for resale.
2. The mixing and loading of blasting agents at blasting sites in accordance with NFPA 495.
3. The use of binary explosives or plosophoric materials in blasting or pyrotechnic special effects applications in accordance with NFPA 495 or NFPA 1126.
[ K. J. ] Add Section 3305.1.1 5605.1.1 to read:
3305.1.1 5605.1.1. Permits. Permits for the manufacture, assembly and testing of explosives, ammunition, blasting agents and fireworks shall be required as set forth in Section 107.2 and regulated in accordance with this section. A permit to manufacture any explosive material in any quantity shall be prohibited unless such manufacture is authorized by a federal license and conducted in accordance with recognized safety practices.
[ L. K. ] Change Section 3306.4 5606.4 to read:
3306.4 5606.4. Storage in residences. Propellants for personal use in quantities not exceeding 50 pounds (23 kg) of black powder or 100 pounds (45 kg) of smokeless powder shall be stored in original containers in occupancies limited to Group Groups R-3 and R-5, or 200 pounds (91 kg) of smokeless powder when stored in the manufacturer's original containers in detached Group U structures that are at least 10 feet from inhabited buildings and are accessory to Group R-3 or R-5. In other than Group R-3 or R-5, smokeless powder in quantities exceeding 20 pounds (9 kg) but not exceeding 50 pounds (23 kg) shall be kept in a wooden box or cabinet having walls of at least one inch (25 mm) nominal thickness or equivalent.
[ M. L. ] Delete Sections 3306.4.1 5606.4.1, 5606.4.2, and 3306.4.2 5606.4.3.
[ N. M. ] Change Section 3306.5.1.1 5606.5.1.1 to read:
3306.5.1.1 5606.5.1.1. Smokeless propellant. No more than 100 pounds (45 kg) of smokeless propellants, in containers of 8 pounds (3.6 kg) or less capacity, shall be displayed in Group M occupancies.
[ O. N. ] Delete Section 3306.5.1.3 5606.5.1.3.
[ P. O. ] Change Section 3306.5.2.1 5606.5.2.1 to read:
3306.5.2.1 5606.5.2.1 Smokeless propellant. Commercial stocks of smokeless propellants shall be stored as follows:
1. Quantities exceeding 20 pounds (9 kg), but not exceeding 100 pounds (45 kg) shall be stored in portable wooden boxes having walls of at least one inch (25 mm) nominal thickness or equivalent.
2. Quantities exceeding 100 pounds (45 kg), but not exceeding 800 pounds (363 kg), shall be stored in storage cabinets having walls at least one inch (25 mm) nominal thickness or equivalent. Not more than 400 pounds (182 kg) shall be stored in any one cabinet, and cabinets shall be separated by a distance of at least 25 feet (7620 mm) or by a fire partition having a fire-resistance rating of at least one hour.
3. Storage of quantities exceeding 800 pounds (363 kg), but not exceeding 5,000 pounds (2270 kg) in a building shall comply with all of the following:
3.1. The storage is inaccessible to unauthorized personnel.
3.2. Smokeless propellant shall be stored in nonportable storage cabinets having wood walls at least one inch (25 mm) nominal thickness or equivalent and having shelves with no more than three feet (914 mm) of vertical separation between shelves.
3.3. No more than 400 pounds (182 kg) is stored in any one cabinet.
3.4. Cabinets shall be located against walls with at least 40 feet (12 192 mm) between cabinets. The minimum required separation between cabinets may be reduced to 20 feet (6096 mm) provided that barricades twice the height of the cabinets are attached to the wall, midway between each cabinet. The barricades must extend a minimum of 10 feet (3048 mm) outward, be firmly attached to the wall, and be constructed of steel not less than 0.25 inch thick (6.4 mm), two-inch (51 mm) nominal thickness wood, brick, or concrete block.
3.5. Smokeless propellant shall be separated from materials classified as combustible liquids, flammable liquids, flammable solids, or oxidizing materials by a distance of 25 feet (7620 mm) or by a fire partition having a fire-resistance rating of one hour.
3.6. The building shall be equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1.
4. Smokeless propellants not stored according to Item 1, 2, or 3 above shall be stored in a Type 2 or 4 magazine in accordance with Section [ 3304 5604 ] and NFPA 495.
[ Q. P. ] Change Section 3307.1 5607.1 to read:
3307.1 5607.1. General. Blasting operations shall be conducted only by persons certified by the SFMO as a restricted or unrestricted blaster or shall be supervised on-site by a person properly certified by the SFMO as a restricted or unrestricted blaster.
[ R. Q. ] Add Section 3307.16 5607.16 to read:
3307.16 5607.16. Blast records. A record of each blast shall be kept and retained for at least five years and shall be [ readily ] available for inspection by the code official. The record shall [ contain the following minimum data: be in a format selected by the blaster and shall contain the minimum data and information indicated in Form 5607.16.
1. Name of contractor;
2. Location and time of blast;
3. Name of certified blaster in charge;
4. Type of material blasted;
5. Number of holes bored and spacing;
6. Diameter and depth of holes;
7. Type and amount of explosives;
8. Amount of explosive per delay of 8 milliseconds or greater;
9. Method of firing and type of circuit;
10. Direction and distance in feet to nearest dwelling, public building, school, church, commercial or institutional building;
11. Weather conditions;
12. Whether or not mats or other precautions were used;
13. Type of detonator and delay period;
14. Type and height of stemming; and
15. Seismograph record when utilized.
Exception: Subdivisions 8 and 13 of this section are not applicable to restricted blasters.
Form 5607.16 Blast (shot) Record |
Block 1 General Information |
1 | Blast date: | Blast Number: | Blast Time: | Permit Number: |
2 | Blast location by address including city, county or town: |
3 | Blast location by GPS coordinates: □ check box if unknown |
4 | Name of Permit Holder: |
5 | Name of Blaster in charge (print): |
6 | Signature of Blaster in charge: |
7 | Certification Number of Blaster in charge: |
|
Block 2 General Environmental Conditions |
1 | Weather (Clear? Cloudy? Overcast?) | Wind direction and speed @________mph | Temperature F° / C° |
2 | Topography (Flat? Hilly? Mountainous?) | Distance from blast site to nearest inhabited building: | Distance from nearest inhabited building determined by: □ GPS coordinates □ Measurement □ Estimated |
3 | Use of nearest inhabited building (Dwelling? Business? Apartment Building? School?) | Direction from blast site to nearest inhabited building: | Direction from blast site to nearest inhabited building determined by: □ GPS instrument □ Compass □ Estimated |
Additional Blaster notations on environmental conditions: |
|
|
Block 3 Shot Layout and Precautions Taken (N/A = Not Applicable) |
1 | Number of holes | Diameter of hole or holes | Depth of hole or holes |
2 | Were any holes decked? □ Yes □ No | How many holes were decked? □ N/A | How many decks per hole? □ N/A |
(If applicable, indicate on any attached shot pattern drawing which holes were decked and the number of decks for the holes.) |
3 | Shot pattern □ Check this box if only single hole. | Depth of sub-drilling | Drilling angle |
4 | Burden | Spacing of holes | Water height |
5 | Stemming height | Material used for stemming | Check box for flyrock precautions taken □ Mats □ Overburden □ None taken |
Additional Blaster notations on shot layout and precautions: |
|
|
Block 4 Seismic Control Measures (N/A = Not Applicable) |
1 | Was scaled distance formula used? □ Yes □ No | Indicate which scaled distance equation was used. □ N/A □ W(lb)={D(ft)/50}2 □ W(lb)={D(ft)/55}2 □ W(lb)={D(ft)/65}2 | Maximum allowable charge weight per 8 ms based on scaled distance. □ N/A |
2 | Was seismograph used? □ Yes □ No | Seismograph manufacturer and model number: □ N/A | Seismograph serial number: □ N/A |
Seismograph's last calibration date. □ N/A |
3 | Distance and direction seismograph from blast site □ N/A | Distance determined by: □ N/A □ GPS coordinates □ Estimated □ Measurement |
4 | Seismograph □ N/A Geophone Minimum Frequency _______Hz Seismograph Microphone Minimum Frequency _______Hz | Seismograph recordings: □ N/A Transverse _____in/s ____ Hz Vertical _____in/s ____ Hz Longitudinal _____in/s ____ Hz Acoustic ______dB ____ Hz |
5 | Seismograph trigger level □ N/A _____ in/s _____dB |
Additional Blaster notations on seismic control measures: |
|
|
Block 5 Quantity and Product |
1 | Maximum allowable charge weight per 8 ms interval □ Delay not used _____ lbs | Initiation (Check) □ Electric □ Non-electric □ Electronic |
2 | Maximum number of holes/decks per 8 ms interval □ Delay not used _____ lbs |
3 | Maximum weight or sticks of explosive per hole _____ lbs | Firing device manufacturer and model: □ N/A |
| Explosive Product listing (Attach additional pages as needed.) |
4 | Manufacturer | Product name, description or brand | Number of units | Unit weight (lb) |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
5 | Total explosive weight in this shot: lbs. |
Additional Blaster notations on product and quantities: |
|
|
Block 6 Completion of Shot Record and General Comments |
General comments on shot not included in notes above: |
Date shot report completed: | Time shot report completed: |
Printed name and signature of person completing shot report if different from Block 1, Lines 5 and 6. | (Print) |
(Signature) |
| | | | | | | | | | | | | | | |
S. R. ] Change Section 3308.2 5608.2 to read:
3308.2 5608.2. Permit application. Prior to issuing permits for a fireworks display, plans for the fireworks display, inspections of the display site and demonstrations of the display operations shall be approved. A plan establishing procedures to follow and actions to be taken in the event that a shell fails to ignite in, or discharge from, a mortar or fails to function over the fallout area or other malfunctions shall be provided to the fire code official.
In addition to the requirements of Section 3301.2.3.1 5601.2.3.1, a permit to conduct a fireworks display shall not be issued to any applicant without the applicant identifying on the application the pyrotechnician who will be in responsible charge of the fireworks display and who is appropriately certified as a pyrotechnician in accordance with Section 3301.4.1 5601.4.1.
Exception: Permits are not required for the use or display of permissible fireworks on private property with the consent of the owner of such property.
[ T. S. ] Change Section 3308.3 5608.3 to read:
3308.3 5608.3. Approved fireworks displays. Approved fireworks displays shall include only the approved fireworks 1.3G, fireworks 1.4G, fireworks 1.4S and pyrotechnic articles 1.4G. The design, setup, conducting or direct on-site supervision of the design, setup and conducting of any fireworks display, either inside a building or outdoors, shall be performed only by persons certified by the SFMO in accordance with Section 3301.4.1 5601.4.1 as a pyrotechnician (firework operator) and at least one person properly certified by the SFMO as a pyrotechnician shall be present at the site where the fireworks display is being conducted. The approved fireworks shall be arranged, located, discharged and fired in a manner that will not pose a hazard to property or endanger any person.
Exception: Certification as a pyrotechnician is not required for the use or display of permissible fireworks when conducted on private property with the consent of the owner of such property.
[ U. T. ] Change Section 3308.4 5608.4 to read:
3308.4 5608.4 Clearance. Spectators, spectator parking areas, and dwellings, buildings or structures shall not be located within the display site. The site for the outdoor land or water display shall have at least 100-ft/in. (31-m/2.4mm) radius of internal mortar [ distance diameter ] of the largest shell to be fired as shown in Table 3308.4 5608.4.
Exceptions:
1. This provision shall not apply to pyrotechnic special effects and fireworks displays using Division 1.4G materials before a proximate audience in accordance with NFPA 1126.
2. This provision shall not apply to unoccupied dwellings, buildings and structures with the approval of the building owner and the fire code official.
[ V. U. ] Add Table 3308.4 5608.4 to read:
|
Table 3308.4. 5608.4 Distances for Outdoor Fireworks Display Sites: Minimum Separation Distances from Mortars to Spectators for Land and Water Displays. |
Mortar Sizea | Minimum Secured Diameter of Site | Vertical Mortarsb | Angled Mortarsc 1/3 offset | Mortars to Special Hazardsd |
in. | mm | ft | m | ft | m | ft | m | ft | m |
<3 | <76 | 300 | 92 | 150 | 46 | 100 | 31 | 300 | 92 |
3 | 76 | 600 | 183 | 300 | 92 | 200 | 61 | 600 | 183 |
4 | 102 | 800 | 244 | 400 | 122 | 266 | 81 | 800 | 244 |
5 | 127 | 1000 | 305 | 500 | 152 | 334 | 102 | 1000 | 305 |
6 | 152 | 1200 | 366 | 600 | 183 | 400 | 122 | 1200 | 366 |
7 | 178 | 1400 | 427 | 700 | 213 | 467 | 142 | 1400 | 427 |
8 | 203 | 1600 | 488 | 800 | 244 | 534 | 163 | 1600 | 488 |
10 | 254 | 2000 | 610 | 1000 | 305 | 667 | 203 | 2000 | 610 |
12 | 305 | 2400 | 732 | 1200 | 366 | 800 | 244 | 2400 | 732 |
>12 | Requires the approval of the fire official |
a Aerial shells, mines, and comets shall be classified and described only in terms of the inside diameter of the mortar from which they are fired (e.g., 3-in. (76-mm) aerial shells, mines and comets are only for use in 3-in. (76mm) mortars). b Where the mortars are positioned vertically, the mortars shall be placed at the approximate center of the display site. c Mortars shall be permitted to be angled during a display to allow for wind and to carry shells away from the main spectator viewing areas. For angled mortars, the minimum secured diameter of the display site does not change. Only the location of the mortars within the secured area changes when the mortars are angled. d Note that this is only the distance to the special hazards. The minimum secured diameter of the display site does not change. |
[ V. W. ] Add Sections 5608.4.1 and 5608.4.2 to read:
5608.4.1. Non-splitting, non-bursting comets and mines. For non-splitting or non-bursting comets and mines containing only stars or non-splitting or non-bursting comets, the minimum required radius of the display site shall be 50 feet per inch (15.24 m per 25.4 mm) of the internal mortar diameter of the largest comet or mine to be fired, one-half that shown in Table 5608.4.
5608.4.2. Special distance requirements. The minimum distance requirements of Table 5608.4 shall be adjusted as follows:
1. For chain-fused aerial shells and comets and mines to be fired from mortars, racks, or other holders that are sufficiently strong to prevent their being repositioned in the event of an explosive malfunction of the aerial shells, comets, or mines, the minimum required radius shall be the same as that required in Sections 5608.4 and 5608.4.1. For chain-fused aerial shells and comets and mines to be fired from mortars, racks, or other holders that are not sufficiently strong to prevent their being repositioned in the event of an explosive malfunction of the aerial shells, comets, or mines, or if there is doubt concerning the strength of racks holding chain-fused mortars, based upon the largest mortar in the sequence, the minimum required radius shall be double that required in Sections 5608.4 and 5608.4.1.
2. Distances from the point of discharge of any firework to a health care or detention and correctional facility, or the bulk storage of materials that have flammability, explosive, or toxic hazard shall be at least twice the distances specified in Table 5608.4.
3. The minimum required spectator separation distance for roman candles and cakes that produce aerial shells, comets, or mine effects shall be the same as the minimum required radius specified in Table 5608.4.
4. Aerial shells, comets and mines, and roman candles and cakes shall be permitted to be angled if the dud shells or components are carried away from the main spectator area and either of the following requirements is satisfied:
4.1. The offset specified in Table 5608.4 is followed.
4.2. The separation distance is correspondingly increased in the direction of the angle.
If the offset provided in Table 5608.4 is followed, the mortars or tubes shall be angled so that any dud shells or components fall at a point approximately equal to the offset of the mortars or tubes from the otherwise required discharge point but in the opposite direction.
[ 13VAC5-51-151. IFC Chapter 57. Flammable and Combustible Liquids.
A. Add Section 5701.1.1 to read:
5701.1.1. Other regulations. Provisions of the Virginia State Water Control Board regulations 9VAC25-91 and 9VAC25-580 addressing the maintenance and operational aspects of underground and aboveground storage tanks subject to those regulations are hereby incorporated by reference to be an enforceable part of this code. Where differences occur between the provisions of this code and the incorporated provisions of the State Water Control Board regulations, the provisions of the State Water Control Board regulations shall apply.
Note: For requirements for the installation, repair, upgrade and closure of such tanks, see Section 414.6.2 of the USBC, Part I, Construction.
B. Change Section 5701.4 to read:
5701.4. Permits. Permits shall be required as set forth in Section 107.2.
C. Add the following exception to Section 5704.2.13.1.3 to read:
Exception: Underground storage tanks subject to the Virginia State Water Control Board regulation 9VAC25-580.
13VAC5-51-151.5. IFC Chapter 58. Flammable Gases and Flammable Cryogenic Fluids.
Change Section 5801.2 to read:
5801.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-152.5. IFC Chapter 59. Flammable Solids.
Change Section 5901.2 to read:
5901.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-153. IFC Chapter 60. Highly Toxic and Toxic Materials.
Change Section 6001.2 to read:
6001.2. Permits. Permits shall be required as set forth in Section 107.2. ]
13VAC5-51-154. IFC Chapter 38 61. Liquefied Petroleum Gases.
A. Change Section 3801.2 6101.2 to read:
3801.2 6101.2. Permits. Permits shall be required as set forth in Section 107.2. Distributors shall not fill an LP-gas container for which a permit is required unless a permit for installation has been issued for that location by the fire code official, except when the container is for temporary use on construction sites.
B. Add Section 3806.4 6106.4 to read:
3806.4 6106.4. DOT DOTn cylinders filled on site. DOT DOTn cylinders in stationary service that are filled on site and therefore are not under the jurisdiction of DOT DOTn either shall be requalified in accordance with DOT DOTn requirements or shall be visually inspected within 12 years of the date of manufacture or within five years from May 1, 2008, whichever is later, and within every five years thereafter, in accordance with the following:
1. Any cylinder that fails one or more of the criteria in Item 3 shall not be refilled or continued in service until the condition is corrected.
2. Personnel shall be trained and qualified to perform inspections.
3. Visual inspection shall be performed in accordance with the following:
3.1. The cylinder is checked for exposure to fire, dents, cuts, digs, gouges, and corrosion according to CGA C-6, Standards for Visual Inspection of Steel Compressed Gas Cylinders, except that paragraph 4.2.1(1) of that standard (which requires tare weight certification), shall not be part of the required inspection criteria.
3.2. The cylinder protective collar (where utilized) and the foot ring are intact and are firmly attached.
3.3. The cylinder is painted or coated to retard corrosion.
3.4. The cylinder pressure relief valve indicates no visible damage, corrosion of operating components, or obstructions.
3.5. There is no leakage from the cylinder or its appurtenances that is detectable without the use of instruments.
3.6. The cylinder is installed on a firm foundation and is not in contact with the soil.
3.7. A cylinder that passed the visual inspection shall be marked with the month and year of the examination followed by the letter "E" (example: 10-01E, indicating requalification in October 2001 by the external inspection method).
3.8. The results of the visual inspection shall be documented, and a record of the inspection shall be retained for a five-year period.
Exception: Any inspection procedure outlined in Items 3.1 through 3.8 that would require a cylinder be moved in such a manner that disconnection from the piping system would be necessary shall be omitted, provided the other inspection results do not indicate further inspection is warranted.
C. Add Sections 3809.15 and 3809.15.1 to read:
3809.15. LP-Gas cylinder exchange for resale. In addition to other applicable requirements of this chapter, facilities operating cylinder exchange stations for LP-gas that are accessible to the public shall comply with the following requirements:
1. Cylinders shall be secured in a lockable, ventilated metal cabinet or other approved enclosure.
2. Cylinders shall be accessible only by authorized personnel or by use of an automated exchange system in accordance with Section 3809.15.1.
3. A sign shall be posted on the entry door of the business operating the cylinder exchange stating "DO NOT BRING LP-GAS CYLINDERS INTO THE BUILDING" or similar approved wording.
4. An emergency contact information sign shall be posted within 10 feet of the cylinder storage cabinet. The content, lettering, size, color and location of the required sign shall be as required by the fire code official.
3809.15.1. Automated Cylinder Exchange Stations. Cylinder exchange stations that include an automated vending system for exchanging cylinders shall comply with the following additional requirements:
1. The vending system shall only permit access to a single cylinder per individual transaction.
2. Cabinets storing cylinders shall be designed such that cylinders can only be placed inside when they are oriented in the upright position.
3. Devices operating door releases for access to stored cylinders shall be permitted to be pneumatic, mechanical or electrically powered.
4. Electrical equipment inside of or within 5 feet of a cabinet storing cylinders, including but not limited to electronics associated with vending operations, shall comply with the requirements for Class 1, Division 2 equipment in accordance with NFPA 70.
5. A manual override control shall be permitted for use by authorized personnel. On newly installed cylinder exchange stations, the vending system shall not be capable of returning to automatic operation after a manual override until the system has been inspected and reset by authorized personnel.
6. Inspections shall be conducted by authorized personnel to verify that all cylinders are secured, access doors are closed and the station has no visible damage or obvious defects that necessitate placing the station out of service. The frequency of inspections shall be as specified by the fire code official.
D. C. Change Section 3811.2 6111.2 to read:
3811.2 6111.2. Unattended parking. The unattended parking of LP-gas tank vehicles shall be in accordance with Sections 3811.2.1 6111.2.1 and 3811.2.2 6111.2.2.
Exception: The unattended outdoor parking of LP-gas tank vehicles may also be in accordance with Section 9.7.2 of NFPA 58.
[ 13VAC5-51-154.2. IFC Chapter 62. Organic Peroxides.
Change Section 6201.2 to read:
6201.2. Permits. Permits shall be required for organic peroxides as set forth in Section 107.2.
13VAC5-51-154.4. IFC Chapter 63. Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids.
Change Section 6301.2 to read:
6301.2. Permits. Permits shall be required as set forth in Section 107.2. ]
13VAC5-51-154.5. IFC Chapter 46. Construction Requirements for Existing Buildings. (Repealed.)
Delete Chapter 46 in its entirety.
[ 13VAC5-51-154.6. IFC Chapter 64. Pyrophoric Materials.
Change Section 6401.2 to read:
6401.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-154.7. IFC Chapter 65. Pyroxylin (Cellulose Nitrate) Plastics.
Change Section 6501.2 to read:
6501.2. Permits. Permits shall be required as set forth in Section 107.2.
13VAC5-51-154.8. IFC Chapter 66. Unstable (Reactive) Materials.
Change Section 6601.2 to read:
6601.2. Permits. Permits shall be required as set forth in Section 107.2. ]
13VAC5-51-155. IFC Chapter 47 80. Referenced Standards.
Change the referenced standards as follows (standards not shown remain the same):
Standard reference number | Title | Referenced in code section number |
CGA C-6 (2001) | Standards for Visual Inspection of Steel Compressed Gas Cylinders | 3806.4 6106.4 |
[ UL 87A-12 | Outline of Investigation for Power-Operated Dispensing Devices for Gasoline and Gasoline/ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent | 2306.8.1 ] |
UL 1037-99 | Standard for Antitheft Alarms and Devices | 506.1 |
UL 1278-00 | Standard for Movable and Wall- or Ceiling-Hung Electric Room Heaters | 605.10.1 |
[ FORMS (13VAC5-51)
Form 5607.16 - Blast (shot) Record (eff. 4/14) ]
DOCUMENTS INCORPORATED BY REFERENCE (13VAC5-51)
The International Fire Code – 2009 2012 Edition, International Code Council, Inc., 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001-2070
CGA C-6 – 2001, Standards for Visual Inspection of Steel Compressed Gas Cylinders, Eighth Edition, Compressed Gas Association, 1725 Jefferson Davis Highway, 5th Floor, Arlington, VA 22202-4102
National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471 (http://www.nfpa.org):
NFPA 58–04 58-11, Liquefied Petroleum Gas Code, 2004 Edition, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
NFPA 70–08 70-11, National Electrical Code, 2008 Edition, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
NFPA 72–07 72-10, National Fire Alarm and Signaling Code, 2007 Edition, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
NFPA 495-10, Explosives Materials Code
NFPA 701-10, Standard Methods of Fire Tests for Flame - Propagation of Textiles and Films
NFPA 1123–06 1123-10, Code for Fireworks Display, 2006 Edition, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
NFPA 1124-06, Code for the Manufacture, Transportation, Storage, and Retail Sales of Fireworks and Pyrotechnic Articles
NFPA 1126–06 1126-11, Standard for the Use of Pyrotechnics Before a Proximate Audience, 2006 Edition, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
UL 1037–99, Standard for Antitheft Alarms and Devices, Fifth Edition, February 24, 1999, Underwriters Laboratories, Inc., Northbrook, IL 60062
[ Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062 (http://www.ul.com):
UL 87A-12, Outline of Investigation for Power-Operated Dispensing Devices for Gasoline and Gasoline/ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent ]
UL 1278–00, Standard for Movable and Wall- or Ceiling-Hung Electric Room Heaters, Third Edition, June 21, 2000 [ , Underwriters Laboratories, Inc., Northbrook, IL 60062 ]
VA.R. Doc. No. R12-3161; Filed March 14, 2014, 9:57 a.m.
TITLE 13. HOUSING
BOARD OF HOUSING AND COMMUNITY DEVELOPMENT
Final Regulation
REGISTRAR'S NOTICE: The Board of Housing and Community Development is claiming an exemption from the Administrative Process Act pursuant to § 2.2-4006 A 12 of the Code of Virginia, which excludes regulations adopted by the Board of Housing and Community Development pursuant to the Uniform Statewide Building Code (§ 36-97 et seq. of the Code of Virginia).
Title of Regulation: 13VAC5-63. Virginia Uniform Statewide Building Code (amending 13VAC5-63-10 through 13VAC5-63-40, 13VAC5-63-70, 13VAC5-63-80, 13VAC5-63-110, 13VAC5-63-120, 13VAC5-63-130, 13VAC5-63-160 through 13VAC5-63-280, 13VAC5-63-300 through 13VAC5-63-330, 13VAC5-63-350 through 13VAC5-63-540; adding 13VAC5-63-225, 13VAC5-63-235, 13VAC5-63-295, 13VAC5-63-298, 13VAC5-63-336, 13VAC5-63-443, 13VAC5-63-445; repealing 13VAC5-63-525).
Statutory Authority: § 36-98 of the Code of Virginia.
Effective Date: July 14, 2014.
Agency Contact: Stephen W. Calhoun, Regulatory Coordinator, Department of Housing and Community Development, Main Street Center, 600 East Main Street, Suite 300, Richmond, VA 23219, telephone (804) 371-7000, FAX (804) 371-7090, TTY (804) 371-7089, or email steve.calhoun@dhcd.virginia.gov.
Summary:
This regulatory action incorporates the newest editions of the model codes, produced by the International Code Council and other standard-writing groups, into the Virginia Uniform Statewide Building Code. The substantive amendments in this regulatory action include the following:
1. 13VAC5-63-30 G: Deletes existing language and adds language that requires compliance with the Virginia Rehabilitation Code (VRC) as related to reconstruction, alteration, and repairs in occupancies other than Group R-5.
2. 13VAC5-63-210 S 65: Deletes all existing language and adds new language to Section R602.12 for practical wall bracing, which allows all buildings in Seismic Design Categories A and B and detached buildings in Category C to be permitted to be braced in accordance with this section as an alternative to Section R602.10. The revisions also add several sections relating to wall bracing requirements and procedures.
3. 13VAC5-63-210 S 85: Revises Section N1102.4.1.2 (R402.4.1.2) for air sealing and requires compliance with either Section N1102.4.1.2.1 or Section N1102.4.1.2.2 and adds sections that (i) specify how the testing option shall be performed when testing for air leakage; (ii) provide that visual inspection is an option for air leakage compliance; and (iii) state that the air leakage rate shall not exceed five changes per hour.
4. 13VAC5-63-220 O: Adds Section 425.2.1 to the IBC for relocated manufactured homes, which specifies that installation, setup, and site work shall comply with the provisions of this code and shall include the option of using the manufacturer's installation instructions or the federal Model Manufactured Home Installation Standards (24 CFR Part 3285) for the technical requirements.
5. 13VAC5-63-220 P: Adds Section 425.2.2 to the IBC for alterations and repairs to manufactured homes, which specifies that alterations and repairs shall be in accordance with federal Manufactured Home Construction and Safety Standards (24 CFR Part 3280) or in accordance with the alteration and repair provisions of this code.
6. 13VAC5-63-350: Addresses existing buildings and contains provisions to be used for alterations, additions, and change of occupancy to existing buildings as well as setting out special retrofit requirements for existing buildings when required by state law.
7. 13VAC5-63-410 B: Changes the scope of the VRC to include mandatory requirements for the alteration and repair of buildings and for changes of occupancy in existing buildings, except for buildings in the Institutional grouping, where Part I of the regulation still applies, and clarifies that the VRC may be used for alterations to residential buildings as an acceptable alternative to the use of Part I of the regulation.
Substantial changes since publication of the proposed regulation include:
1. 13VAC5-63-210 S 66-75 and 13VAC5-63-295: Modifies tables for wood frame construction in homes and in commercial buildings to reflect new stress values for southern yellow pine lumber developed by the lumber grading industry.
2. 13VAC5-63-220 Y and Z: Adds new requirements addressing the use of holding cells in courthouses and police departments.
3. 13VAC5-63-240 R: Adds new requirements for the installation of carbon monoxide detectors in new school buildings where fuel-fired appliances are used.
4. 13VAC5-63-260 D: Adds requirements for ventilation and separation of smoking areas in restaurants to match requirements of the Virginia Safe Smoking Act.
5. 13VAC5-63-330 C: Clarifies the requirements for protecting elevator machine rooms and control rooms and spaces from hazards incident to the elevator shaft for newer designed machine-room-less elevators.
Part I
Construction
13VAC5-63-10. Chapter 1 Administration; Section 101 General.
A. Section 101.1 Short title. The Virginia Uniform Statewide Building Code, Part I, Construction, may be cited as the Virginia Construction Code or as the VCC. The term "USBC" shall mean the Virginia Construction Code VCC unless the context in which the term is used clearly indicates it to be an abbreviation for the entire Virginia Uniform Statewide Building Code or for a different part of the Virginia Uniform Statewide Building Code.
Note: This code is also known as the 2009 2012 edition of the USBC due to the use of the 2009 2012 editions of the model codes.
B. Section 101.2 Incorporation by reference. Chapters 2 - 35 of the 2009 2012 International Building Code, published by the International Code Council, Inc., are adopted and incorporated by reference to be an enforceable part of the USBC. The term "IBC" means the 2009 2012 International Building Code, published by the International Code Council, Inc. Any codes and standards referenced in the IBC are also considered to be part of the incorporation by reference, except that such codes and standards are used only to the prescribed extent of each such reference. In addition, any provisions of the appendices of the IBC specifically identified to be part of the USBC are also considered to be part of the incorporation by reference.
Note 1: The IBC references the whole family of other International Codes and standards including the following major codes:
2009 2012 International Plumbing Code (IPC)
2009 2012 International Mechanical Code (IMC)
2008 2011 NFPA 70
2009 2012 International Fuel Gas Code (IFGC)
2009 2012 International Energy Conservation Code (IECC)
2009 2012 International Residential Code (IRC)
Note 2: The International Residential Code IRC is applicable to the construction of detached one- and two-family dwellings and townhouses as set out in Section 310.
C. Section 101.3 Numbering system. A dual numbering system is used in the USBC to correlate the numbering system of the Virginia Administrative Code with the numbering system of the IBC. IBC numbering system designations are provided in the catchlines of the Virginia Administrative Code sections. Cross references between sections or chapters of the USBC use only the IBC numbering system designations. The term "chapter" is used in the context of the numbering system of the IBC and may mean a chapter in the USBC, a chapter in the IBC or a chapter in a referenced code or standard, depending on the context of the use of the term. The term "chapter" is not used to designate a chapter of the Virginia Administrative Code, unless clearly indicated.
D. Section 101.4 Arrangement of code provisions. The USBC is comprised of the combination of (i) the provisions of Chapter 1, Administration, which are established herein, (ii) Chapters 2 - 35 of the IBC, which are incorporated by reference in Section 101.2, and (iii) the changes to the text of the incorporated chapters of the IBC that are specifically identified. The terminology "changes to the text of the incorporated chapters of the IBC that are specifically identified" shall also be referred to as the "state amendments to the IBC." Such state amendments to the IBC are set out using corresponding chapter and section numbers of the IBC numbering system. In addition, since Chapter 1 of the IBC is not incorporated as part of the USBC, any reference to a provision of Chapter 1 of the IBC in the provisions of Chapters 2 - 35 of the IBC is generally invalid. However, where the purpose of such a reference would clearly correspond to a provision of Chapter 1 established herein, then the reference may be construed to be a valid reference to such corresponding Chapter 1 provision.
E. Section 101.5 Use of terminology and notes. The term "this code," or "the code," where used in the provisions of Chapter 1, in Chapters 2 - 35 of the IBC or in the state amendments to the IBC means the USBC, unless the context clearly indicates otherwise. The term "this code" or "the code" where used in a code or standard referenced in the IBC means that code or standard, unless the context clearly indicates otherwise. The use of notes in Chapter 1 is to provide information only and shall not be construed as changing the meaning of any code provision. Notes in the IBC, in the codes and standards referenced in the IBC and in the state amendments to the IBC may modify the content of a related provision and shall be considered to be a valid part of the provision, unless the context clearly indicates otherwise.
F. Section 101.6 Order of precedence. The provisions of this code shall be used as follows:
1. The provisions of Chapter 1 of this code supersede any conflicting provisions of Chapters 2 - 35 of the IBC and that address the same subject matter and impose differing requirements.
2. The provisions of Chapter 1 of this code supersede any conflicting provisions of the codes and standards referenced in the IBC that address the same subject matter and impose differing requirements. In addition, the
3. The state amendments to the IBC supersede any conflicting provisions of Chapters 2 - 35 of the IBC and that address the same subject matter and impose differing requirements.
4. The state amendments to the IBC supersede any conflicting provisions of the codes and standards referenced in the IBC that address the same subject matter and impose differing requirements. Further, the
5. The provisions of Chapters 2 - 35 of the IBC supersede any conflicting provisions of the codes and standards referenced in the IBC that address the same subject matter and impose differing requirements.
G. Section 101.7 Administrative provisions. The provisions of Chapter 1 establish administrative requirements, which include but are not limited to provisions relating to the scope of the code, enforcement, fees, permits, inspections and disputes. Any provisions of Chapters 2 - 35 of the IBC or any provisions of the codes and standards referenced in the IBC that address the same subject matter and impose differing requirements are deleted and replaced by the provisions of Chapter 1. Further, any administrative requirements contained in the state amendments to the IBC shall be given the same precedence as the provisions of Chapter 1. Notwithstanding the above, where administrative requirements of Chapters 2 - 35 of the IBC or of the codes and standards referenced in the IBC are specifically identified as valid administrative requirements in Chapter 1 of this code or in the state amendments to the IBC, then such requirements are not deleted and replaced.
Note: The purpose of this provision is to eliminate overlap, conflicts and duplication by providing a single standard for administrative, procedural and enforcement requirements of this code.
H. Section 101.8 Definitions. The definitions of terms used in this code are contained in Chapter 2 along with specific provisions addressing the use of definitions. Terms may be defined in other chapters or provisions of the code and such definitions are also valid.
Note: The order of precedence outlined in Section 101.6 may be determinative in establishing how to apply the definitions in the IBC and in the referenced codes and standards.
13VAC5-63-20. Section 102 Purpose and scope.
A. Section 102.1 Purpose. In accordance with § 36-99 of the Code of Virginia, the purpose of the USBC is to protect the health, safety and welfare of the residents of the Commonwealth of Virginia, provided that buildings and structures should be permitted to be constructed at the least possible cost consistent with recognized standards of health, safety, energy conservation and water conservation, including provisions necessary to prevent overcrowding, rodent or insect infestation, and garbage accumulation; and barrier-free provisions for the physically handicapped and aged.
B. Section 102.2 Scope. This section establishes the scope of the USBC in accordance with § 36-98 of the Code of Virginia. The USBC shall supersede the building codes and regulations of the counties, municipalities and other political subdivisions and state agencies. This code also shall supersede the provisions of local ordinances applicable to single-family residential construction that (i) regulate dwelling foundations or crawl spaces, (ii) require the use of specific building materials or finishes in construction, or (iii) require minimum surface area or numbers of windows; however, this code shall not supersede proffered conditions accepted as a part of a rezoning application, conditions imposed upon the grant of special exceptions, special or conditional use permits or variances, conditions imposed upon a clustering of single-family homes and preservation of open space development through standards, conditions, and criteria established by a locality pursuant to subdivision 8 of § 15.2-2242 of the Code of Virginia or subdivision A 12 of § 15.2-2286 of the Code of Virginia, or land use requirements in airport or highway overlay districts, or historic districts created pursuant to § 15.2-2306 of the Code of Virginia, or local flood plain regulations adopted as a condition of participation in the National Flood Insurance Program.
Note: Requirements relating to functional design are contained in Section [ 103.11 103.10 ] of this code.
C. Section 102.2.1 Invalidity of provisions. To the extent that any provisions of this code are in conflict with Chapter 6 (§ 36-97 et seq.) of Title 36 of the Code of Virginia or in conflict with the scope of the USBC, those provisions are considered to be invalid to the extent of such conflict.
D. Section 102.3 Exemptions. The following are exempt from this code:
1. Equipment, related wiring, and poles and towers supporting the related wiring installed by a provider of publicly regulated utility service or a franchised cable television operator and electrical equipment and related wiring used for radio, broadcast or cable television, telecommunications or information service transmission. The exemption shall apply only if under applicable federal and state law the ownership and control of the equipment and wiring is by the service provider or its affiliates. Such exempt equipment and wiring shall be located on either rights-of-way or property for which the service provider has rights of occupancy and entry; however, the structures, including their service equipment, housing or supporting such exempt equipment and wiring shall be subject to the USBC. The installation of equipment and wiring exempted by this section shall not create an unsafe condition prohibited by the USBC.
2. Manufacturing and processing machines that do not produce or process hazardous materials regulated by this code, including all of the following service equipment associated with the manufacturing or processing machines.
2.1. Electrical equipment connected after the last disconnecting means.
2.2. Plumbing piping and equipment connected after the last shutoff valve or backflow device and before the equipment drain trap.
2.3. Gas piping and equipment connected after the outlet shutoff valve.
Manufacturing and processing machines that produce or process hazardous materials regulated by this code are only required to comply with the code provisions regulating the hazardous materials.
3. Parking lots and sidewalks, which that are not part of an accessible route.
4. Nonmechanized playground or recreational equipment such as swing sets, sliding boards, climbing bars, jungle gyms, skateboard ramps, and similar equipment where no admission fee is charged for its use or for admittance to areas where the equipment is located.
5. Industrialized buildings subject to the Virginia Industrialized Building Safety Regulations (13VAC5-91) and manufactured homes subject to the Virginia Manufactured Home Safety Regulations (13VAC5-95); except as provided for in Section 424 425.
6. Farm buildings and structures, except for a building or a portion of a building located on a farm that is operated as a restaurant as defined in § 35.1-1 of the Code of Virginia and licensed as such by the Virginia Board of Health pursuant to Chapter 2 (§ 35.1-11 et seq.) of Title 35.1 of the Code of Virginia. However, farm buildings and structures lying within a flood plain or in a mudslide-prone area shall be subject to flood-proofing regulations or mudslide regulations, as applicable.
7. Federally owned buildings and structures unless federal law specifically requires a permit from the locality. Underground storage tank installations, modifications and removals shall comply with this code in accordance with federal law.
8. Off-site manufactured intermodal freight containers, moving containers, and storage containers placed on site temporarily or permanently for use as a storage container.
9. Automotive lifts.
13VAC5-63-30. Section 103 Application of code.
A. Section 103.1 General. In accordance with § 36-99 of the Code of Virginia, the USBC shall prescribe building regulations to be complied with in the construction and rehabilitation of buildings and structures, and the equipment therein.
B. Section 103.2 When applicable to new construction. Construction for which a permit application is submitted to the local building department on or after the effective date of the 2009 2012 edition of the code shall comply with the provisions of this code, except for permit applications submitted during a one-year period after beginning on the effective date of the 2009 2012 edition of the code. The applicant for a permit during such one-year period shall be permitted to choose whether to comply with the provisions of this code or the provisions of the edition of the code in effect immediately prior to the 2009 2012 edition. This provision shall also apply to subsequent amendments to this code based on the effective date of such amendments. In addition, when a permit has been properly issued under a previous edition of this code, this code shall not require changes to the approved construction documents, design or construction of such a building or structure, provided the permit has not been suspended or revoked.
C. Section 103.3 Change of occupancy. No change of occupancy shall be made in any structure when the current USBC requires a greater degree of accessibility, structural strength, fire protection, means of egress, ventilation or sanitation. When such a greater degree is required, the owner or the owner's agent shall make comply with the following:
1. When involving Group I-2 or I-3, written application shall be made to the local building department for a new certificate of occupancy and shall obtain the new certificate of occupancy shall be obtained prior to the new use of the structure. When impractical to achieve compliance with this code for the new occupancy classification, the building official shall consider modifications upon application and as provided for in Section 106.3. In addition, the applicable accessibility provisions of Section 1012.8 of Part II of the Virginia Uniform Statewide Building Code, also known as the "Virginia Rehabilitation Code," or the "VRC" shall be met.
Exception: This section shall not be construed to permit noncompliance with any applicable flood load or flood-resistant construction requirements of this code.
2. In other than Group I-2 or I-3, the provisions of the VRC for change of occupancy shall be met.
D. Section 103.4 Additions. Additions to buildings and structures shall comply with the requirements of this code for new construction and an or shall comply with the VRC. An existing building or structure plus additions shall comply with the height and area provisions of Chapter 5 and the applicable provisions of Chapter 9. Further, this code shall not require changes to the design or construction of any portions of the building or structure not altered or affected by an addition, unless the addition has the effect of lowering the current level of safety.
Exception Exceptions:
1. This section shall not be construed to permit noncompliance with any applicable flood load or flood-resistant construction requirements of this code.
2. When this code is used for compliance, existing structural elements carrying gravity loads shall be permitted to comply with Section 1103 of the International Existing Building Code.
E. Section 103.5 Reconstruction, alteration or repair in Group R-5 occupancies. The following criteria is applicable to reconstruction, alteration or repair of Group R-5 buildings or structures:
1. Any reconstruction, alteration or repair shall not adversely affect the performance of the building or structure, or cause the building or structure to become unsafe or lower existing levels of health and safety.
2. Parts of the building or structure not being reconstructed, altered or repaired shall not be required to comply with the requirements of this code applicable to newly constructed buildings or structures.
3. The installation of material or equipment, or both, that is neither required nor prohibited shall only be required to comply with the provisions of this code relating to the safe installation of such material or equipment.
4. Material or equipment, or both, may be replaced in the same location with material or equipment of a similar kind or capacity.
Exceptions:
1. This section shall not be construed to permit noncompliance with any applicable flood load or flood-resistant construction requirements of this code.
2. Reconstructed decks, balconies, porches and similar structures located 30 inches (762 mm) or more above grade shall meet the current code provisions for structural loading capacity, connections and structural attachment. This requirement excludes the configuration and height of handrails and guardrails.
3. Compliance with the VRC shall be an acceptable alternative to compliance with this section at the discretion of the owner or owner's agent.
F. Section 103.5.1 Equipment changes. Upon the replacement or new installation of any fuel-burning appliances or equipment in existing Group R-5 occupancies, an inspection or inspections shall be conducted to ensure that the connected vent or chimney systems comply with the following:
1. Vent or chimney systems are sized in accordance with the IRC.
2. Vent or chimney systems are clean, free of any obstruction or blockages, defects, or deterioration, and are in operable condition. Where not inspected by the local building department, persons performing such changes or installations shall certify to the building official that the requirements of Items 1 and 2 of this section are met.
F. G. Section 103.6. Use of rehabilitation code Reconstruction, alteration, and repair in other occupancies. Compliance with Part II of the Virginia Uniform Statewide Building Code, also known as the "Virginia Rehabilitation Code," shall be an acceptable alternative to compliance with this code for the rehabilitation of such existing buildings and structures within the scope of that code. For the purposes of this section, the term "rehabilitation" shall be as defined in the Virginia Rehabilitation Code Reconstruction, alteration, and repair in occupancies other than Group R-5 shall comply with the VRC.
G. H. Section 103.7. Retrofit requirements. The local building department shall enforce the provisions of Section 3413 1701 of the VRC, which require certain existing buildings to be retrofitted with fire protection systems and other safety equipment. Retroactive fire protection system requirements contained in the International Fire Code (IFC) shall not be applicable unless required for compliance with the provisions of Section 3413 1701 of the VRC.
H. I. Section 103.8 Nonrequired equipment. The following criteria for nonrequired equipment is in accordance with § 36-103 of the Code of Virginia. Building owners may elect to install partial or full fire alarms or other safety equipment that was not required by the edition of the USBC in effect at the time a building was constructed without meeting current requirements of the code, provided the installation does not create a hazardous condition. Permits for installation shall be obtained in accordance with this code. In addition, as a requirement of this code, when such nonrequired equipment is to be installed, the building official shall notify the appropriate fire official or fire chief.
I. J. Section 103.8.1 Reduction in function or discontinuance of nonrequired fire protection systems. When a nonrequired fire protection system is to be reduced in function or discontinued, it shall be done in such a manner so as not to create a false sense of protection. Generally, in such cases, any features visible from interior areas shall be removed, such as sprinkler heads, smoke detectors or alarm panels or devices, but any wiring or piping hidden within the construction of the building may remain. Approval of the proposed method of reduction or discontinuance shall be obtained from the building official.
J. Section 103.9 Equipment changes. Upon the replacement or new installation of any fuel-burning appliances or equipment in existing buildings, an inspection or inspections shall be conducted to ensure that the connected vent or chimney systems comply with the following:
1. Vent or chimney systems are sized in accordance with either the International Residential Code, the International Mechanical Code or the International Fuel Gas Code, depending on which is applicable based on the fuel source and the occupancy classification of the structure.
2. Vent or chimney systems are clean, free of any obstruction or blockages, defects or deterioration and are in operable condition.
Where not inspected by the local building department, persons performing such changes or installations shall certify to the building official that the requirements of Items 1 and 2 of this section are met.
K. Section 103.10 [ 103.8 103.9 ] Use of certain provisions of referenced codes. The following provisions of the IBC and of other indicated codes or standards are to be considered valid provisions of this code. Where any such provisions have been modified by the state amendments to the IBC, then the modified provisions apply.
1. Special inspection requirements in Chapters 2 - 35.
2. Chapter 34, Existing Structures, except that Section 3412, Compliance Alternatives, shall not be used to comply with the retrofit requirements identified in Section 103.7 and shall not be construed to permit noncompliance with any applicable flood load or flood-resistant construction requirements of this code.
3. 2. Testing requirements and requirements for the submittal of construction documents in any of the ICC codes referenced in Chapter 35 and in the IRC.
4. 3. Section R301.2 of the International Residential Code IRC authorizing localities to determine climatic and geographic design criteria.
5. 4. Flood load or flood-resistant construction requirements in the IBC or the International Residential Code IRC, including, but not limited to, any such provisions pertaining to flood elevation certificates that are located in Chapter 1 of those codes. Any required flood elevation certificate pursuant to such provisions shall be prepared by a land surveyor licensed in Virginia or an RDP.
6. 5. Section R101.2 of the IRC.
[ 6. Section N1101.6 of the IRC and Sections C101.5.2 and R101.5.2 of the IECC. ]
L. Section [ 103.11 103.10 ] Functional design. The following criteria for functional design is in accordance with § 36-98 of the Code of Virginia. The USBC shall not supersede the regulations of other state agencies that require and govern the functional design and operation of building related activities not covered by the USBC, including but not limited to (i) public water supply systems, (ii) waste water treatment and disposal systems, and (iii) solid waste facilities, nor. Nor shall state agencies be prohibited from requiring, pursuant to other state law, that buildings and equipment be maintained in accordance with provisions of this code. In addition, as established by this code, the building official may refuse to issue a permit until the applicant has supplied certificates of functional design approval from the appropriate state agency or agencies. For purposes of coordination, the locality may require reports to the building official by other departments or agencies indicating compliance with their regulations applicable to the functional design of a building or structure as a condition for issuance of a building permit or certificate of occupancy. Such reports shall be based upon review of the plans or inspection of the project as determined by the locality. All enforcement of these conditions shall not be the responsibility of the building official, but rather the agency imposing the condition.
Note: Identified state agencies with functional design approval are listed in the "Related Laws Package," which is available from DHCD.
M. Section [ 103.12 103.11 ] Amusement devices and inspections. In accordance with § 36-98.3 of the Code of Virginia, to the extent they are not superseded by the provisions of § 36-98.3 of the Code of Virginia and the VADR, the provisions of the USBC shall apply to amusement devices. In addition, as a requirement of this code, inspections for compliance with the VADR shall be conducted either by local building department personnel or private inspectors provided such persons are certified as amusement device inspectors under the VCS.
N. Section [ 103.13 103.12 ] State buildings and structures. This section establishes the application of the USBC to state-owned buildings and structures in accordance with § 36-98.1 of the Code of Virginia. The USBC shall be applicable to all state-owned buildings and structures, with the exception that §§ 2.2-1159 [ , 2.2-1160 and through ] 2.2-1161 of the Code of Virginia shall provide the standards for ready access to and use of state-owned buildings by the physically handicapped.
Any state-owned building or structure for which preliminary plans were prepared or on which construction commenced after the initial effective date of the USBC, shall remain subject to the provisions of the USBC that were in effect at the time such plans were completed or such construction commenced. Subsequent reconstruction, renovation or demolition of such building or structure shall be subject to the pertinent provisions of this code.
Acting through the Division of Engineering and Buildings, the Virginia Department of General Services shall function as the building official for state-owned buildings. The department shall review and approve plans and specifications, grant modifications, and establish such rules and regulations as may be necessary to implement this section. It shall provide for the inspection of state-owned buildings and enforcement of the USBC and standards for access by the physically handicapped by delegating inspection and USBC enforcement duties to the State Fire Marshal's Office, to other appropriate state agencies having needed expertise, and to local building departments, all of which shall provide such assistance within a reasonable time and in the manner requested. State agencies and institutions occupying buildings shall pay to the local building department the same fees as would be paid by a private citizen for the services rendered when such services are requested by the department. The department may alter or overrule any decision of the local building department after having first considered the local building department's report or other rationale given for its decision. When altering or overruling any decision of a local building department, the department shall provide the local building department with a written summary of its reasons for doing so.
Notwithstanding any provision of this code to the contrary, roadway tunnels and bridges owned by the Virginia Department of Transportation shall be exempt from this code. The Virginia Department of General Services shall not have jurisdiction over such roadway tunnels, bridges and other limited access highways; provided, however, that the Department of General Services shall have jurisdiction over any occupied buildings within any Department of Transportation rights-of-way that are subject to this code.
Except as provided in [ subdivision subsection ] D of § 23-38.109 D of the Code of Virginia, and notwithstanding any provision of this code to the contrary, at the request of a public institution of higher education, the Virginia Department of General Services, as further set forth in this provision, shall authorize that institution of higher education to contract with a building official of the locality in which the construction is taking place to perform any inspection and certifications required for the purpose of complying with this code. The department shall publish administrative procedures that shall be followed in contracting with a building official of the locality. The authority granted to a public institution of higher education under this provision to contract with a building official of the locality shall be subject to the institution meeting the conditions prescribed in [ subdivision subsection ] B of § 23-38.88 B of the Code of Virginia.
Note: In accordance with § 36-98.1 of the Code of Virginia, roadway tunnels and bridges shall be designed, constructed and operated to comply with fire safety standards based on nationally recognized model codes and standards to be developed by the Virginia Department of Transportation in consultation with the State Fire Marshal and approved by the Virginia Commonwealth Transportation Board. Emergency response planning and activities related to the standards approved by the Commonwealth Transportation Board shall be developed by the Department of Transportation and coordinated with the appropriate local officials and emergency service providers. On an annual basis, the Department of Transportation shall provide a report on the maintenance and operability of installed fire protection and detection systems in roadway tunnels and bridges to the State Fire Marshal.
O. Section [ 103.13.1 103.12.1 ] Certification of state enforcement personnel. State enforcement personnel shall comply with the applicable requirements of Section 105 for certification, periodic maintenance training, and continuing education.
13VAC5-63-40. Section 104 Enforcement, generally.
A. Section 104.1 Scope of enforcement. This section establishes the requirements for enforcement of the USBC in accordance with § 36-105 of the Code of Virginia. Enforcement of the provisions of the USBC for construction and rehabilitation shall be the responsibility of the local building department. Whenever a county or municipality does not have such a building department, the local governing body shall enter into an agreement with the local governing body of another county or municipality or with some other agency, or a state agency approved by DHCD for such enforcement. For the purposes of this section, towns with a population of less than 3,500 may elect to administer and enforce the USBC; however, where the town does not elect to administer and enforce the code, the county in which the town is situated shall administer and enforce the code for the town. In the event such town is situated in two or more counties, those counties shall administer and enforce the USBC for that portion of the town situated within their respective boundaries.
Upon However, upon a finding by the local building department, following a complaint by a tenant of a residential rental dwelling unit that is the subject of such complaint, that there may be a violation of the unsafe structures provisions of Part III of the Virginia Uniform Statewide Building Code, also known as the "Virginia Maintenance Code," or the "VMC," the local building department shall enforce such provisions.
If the local building department receives a complaint that a violation of the Virginia Maintenance Code VMC exists that is an immediate and imminent threat to the health or safety of the owner or, tenant, or occupants of a residential dwelling unit or a nearby residential dwelling unit, and any building or structure, or the owner, occupant, or tenant [ or of ] any nearby building or structure, and the owner, occupant, or tenant of the residential dwelling unit building or structure that is the subject of the complaint has refused to allow the local building official or his agent to have access to the subject dwelling building or structure, the local building official or his agent may present sworn testimony to a magistrate or a court of competent jurisdiction and request that the magistrate or court grant the local building official or his agent an inspection warrant to enable the building official or his agent to enter the subject dwelling building or structure for the purpose of determining whether violations of the Virginia Maintenance Code VMC exist. The local building official or his agent shall make a reasonable effort to obtain consent from the owner, occupant, or tenant of the subject dwelling building or structure prior to seeking the issuance of an inspection warrant under this section.
The local governing body shall, however, inspect and enforce the provisions of the Virginia Maintenance Code VMC for elevators, escalators, and related conveyances, except for elevators in single-family and two-family homes and townhouses. Such inspection and enforcement shall be carried out by an agency or department designated by the local governing body.
B. Section 104.2 Interagency coordination. When any inspection functions under this code are assigned to a local agency other than the local building department, such agency shall coordinate its reports of inspection with the local building department.
C. 104.3 Transfer of ownership. If the local building department has initiated an enforcement action against the owner of a building or structure and such owner subsequently transfers the ownership of the building or structure to an entity in which the owner holds an ownership interest greater than 50%, the pending enforcement action shall continue to be enforced against the owner.
[ 13VAC5-63-70. Section 107 Fees.
A. Section 107.1 Authority for charging fees. In accordance with § 36-105 of the Code of Virginia, fees may be levied by the local governing body in order to defray the cost of enforcement of the USBC.
B. Section 107.1.1 Fee schedule. The local governing body shall establish a fee schedule incorporating unit rates, which may be based on square footage, cubic footage, estimated cost of construction or other appropriate criteria. A permit or any amendments to an existing permit shall not be issued until the designated fees have been paid, except that the building official may authorize the delayed payment of fees.
C. Section 107.1.2 Refunds. When requested in writing by a permit holder, the locality shall provide a fee refund in the case of the revocation of a permit or the abandonment or discontinuance of a building project. The refund shall not be required to exceed an amount which correlates to work not completed.
D. Section 107.1.3 Fees for generators used with amusement devices. Fees for generators and associated wiring used with amusement devices shall only be charged under the Virginia Amusement Device Regulations (13VAC5-31).
D. E. Section 107.2 Code academy fee levy. In accordance with subdivision 7 of § 36-137 of the Code of Virginia, the local building department shall collect a 2.0% levy of fees charged for permits issued under this code and transmit it quarterly to DHCD to support training programs of the Virginia Building Code Academy. Localities that maintain individual or regional training academies accredited by DHCD shall retain such levy. ]
13VAC5-63-80. Section 108 Application for permit.
A. Section 108.1 When applications are required. Application for a permit shall be made to the building official and a permit shall be obtained prior to the commencement of any of the following activities, except that applications for emergency construction, alterations or equipment replacement shall be submitted by the end of the first working day that follows the day such work commences. In addition, the building official may authorize work to commence pending the receipt of an application or the issuance of a permit.
1. Construction or demolition of a building or structure. Installations or alterations involving (i) the removal or addition of any wall, partition or portion thereof, (ii) any structural component, (iii) the repair or replacement of any required component of a fire or smoke rated assembly, (iv) the alteration of any required means of egress system, (v) water supply and distribution system, sanitary drainage system or vent system, (vi) electric wiring, (vii) fire protection system, mechanical systems, or fuel supply systems, or (viii) any equipment regulated by the USBC.
2. For change of occupancy, application for a permit shall be made when a new certificate of occupancy is required under Section 103.3.
3. Movement of a lot line that increases the hazard to or decreases the level of safety of an existing building or structure in comparison to the building code under which such building or structure was constructed.
4. Removal or disturbing of any asbestos containing materials during the construction or demolition of a building or structure, including additions.
B. Section 108.2 Exemptions from application for permit. Notwithstanding the requirements of Section 108.1, application for a permit and any related inspections shall not be required for the following; however, this section shall not be construed to exempt such activities from other applicable requirements of this code. In addition, when an owner or an owner's agent requests that a permit be issued for any of the following, then a permit shall be issued and any related inspections shall be required.
1. Installation of wiring and equipment that (i) operates at less than 50 volts, (ii) is for network powered broadband communications systems, or (iii) is exempt under Section 102.3(1), except when any such installations are located in a plenum, penetrate fire rated or smoke protected construction or are a component of any of the following:
1.1. Fire alarm system.
1.2. Fire detection system.
1.3. Fire suppression system.
1.4. Smoke control system.
1.5. Fire protection supervisory system.
1.6. Elevator fire safety control system.
1.7. Access or egress control system or delayed egress locking or latching system.
1.8. Fire damper.
1.9. Door control system.
2. One story detached accessory structures used as tool and storage sheds, playhouses or similar uses, provided the floor building area does not exceed 200 256 square feet (18 m2 (23.78 m2) and the structures are not classified as a Group F-1 or H occupancy.
3. Detached prefabricated buildings housing the equipment of a publicly regulated utility service, provided the floor area does not exceed 150 square feet (14 m2).
4. Tents or air-supported structures, or both, that cover an area of 900 square feet (84 m2) or less, including within that area all connecting areas or spaces with a common means of egress or entrance, provided such tents or structures have an occupant load of 50 or less persons.
5. Fences and privacy walls not part of a building, structure or of any height unless required for pedestrian safety as provided for by Section 3306, or used for the barrier for a swimming pool,.
6. Concrete or masonry walls, provided such fences and privacy walls do not exceed six feet in height above the finished grade. Ornamental post column caps shall not be considered to contribute to the height of the fence or privacy wall and shall be permitted to extend above the six feet height measurement.
6. 7. Retaining walls supporting less than two three feet of unbalanced fill. This exemption shall not apply to any wall that are not constructed for the purpose of impounding Class I, II or III-A liquids or supporting a surcharge other than ordinary unbalanced fill.
7. 8. Swimming pools that have a surface area not greater than 150 square feet (13.95 m2), do not exceed 5,000 gallons (19 000 L) and are less than 24 inches (610 mm) deep.
8. 9. Signs under the conditions in Section H101.2 of Appendix H.
9. 10. Replacement of above-ground existing LP-gas containers of the same capacity in the same location and associated regulators when installed by the serving gas supplier.
[ 11. Flagpoles 30 feet (9144 mm) or less in height.
12. Temporary ramps serving dwelling units in Group R-3 and R-5 occupancies where the height of the entrance served by the ramp is no more than 30 inches (762 mm) above grade.
13. Construction work deemed by the building official to be minor and ordinary and which does not adversely affect public health or general safety. ]
10. [ 11. 14. ] Ordinary repairs that include the following:
10.1. [ 11.1. 14.1. ] Replacement of windows and doors with windows and doors of similar operation and opening dimensions that do not require changes to the existing framed opening and that are not required to be fire rated in Group R-2 where serving a single dwelling unit and in Groups R-3, R-4 and R-5.
10.2. [ 11.2. 14.2. ] Replacement of plumbing fixtures and well pumps in all groups without alteration of the water supply and distribution systems, sanitary drainage systems or vent systems.
10.3. [ 11.3. 14.3. ] Replacement of general use snap switches, dimmer and control switches, 125 volt-15 or 20 ampere receptacles, [ luminaries luminaires ] (lighting fixtures) and ceiling (paddle) fans in Group R-2 where serving a single dwelling unit and in Groups R-3, R-4 and R-5.
10.4. [ 11.4. 14.4. ] Replacement of mechanical appliances provided such equipment is not fueled by gas or oil in Group R-2 where serving a single family dwelling and in Groups R-3, R-4 and R-5.
10.5. [ 11.5. 14.5. ] Replacement of an unlimited amount of roof covering or siding in Groups R-3, R-4 or R-5 provided the building or structure is not in an area where the design (3 second gust) wind speed is greater than 100 miles per hour (160 km/hr) and replacement of 100 square feet (9.29 m2) or less of roof covering in all groups and all wind zones.
10.6. [ 11.6. 14.6. ] Replacement of 100 square feet (9.29 m2) or less of roof decking in Groups R-3, R-4 or R-5 unless the decking to be replaced was required at the time [ or of ] original construction to be fire-retardant-treated or protected in some other way to form a fire-rated wall termination.
10.7. [ 11.7. 14.7. ] Installation or replacement of floor finishes in all occupancies.
10.8. [ 11.8. 14.8. ] Replacement of Class C interior wall or ceiling finishes installed in Groups A, E and I and replacement of all classes of interior wall or ceiling finishes in other groups.
10.9. [ 11.9. 14.9. ] Installation of or replacement of cabinetry or trim.
10.10. [ 11.10 14.10. ] Application of paint or wallpaper.
10.11. [ 11.11. 14.11. ] Other repair work deemed by the building official to be minor and ordinary which does not adversely affect public health or general safety.
[ 12. 15. ] Crypts, mausoleums, and columbaria structures not exceeding 1500 square feet (139.35 m2) in area if the building or structure is not for occupancy and used solely for the interment of human or animal remains and is not subject to special inspections.
Exception: Application for a permit may be required by the building official for the installation of replacement siding, roofing and windows in buildings within a historic district designated by a locality pursuant to § 15.2-2306 of the Code of Virginia.
C. Section 108.3 Applicant information, processing by mail. Application for a permit shall be made by the owner or lessee of the relevant property or the agent of either or by the RDP, contractor or subcontractor associated with the work or any of their agents. The full name and address of the owner, lessee and applicant shall be provided in the application. If the owner or lessee is a corporate body, when and to the extent determined necessary by the building official, the full name and address of the responsible officers shall also be provided.
A permit application may be submitted by mail and such permit applications shall be processed by mail, unless the permit applicant voluntarily chooses otherwise. In no case shall an applicant be required to appear in person.
The building official may accept applications for a permit through electronic submissions provided the information required by this section is obtained.
D. Section 108.4 Prerequisites to obtaining permit. In accordance with § 54.1-1111 of the Code of Virginia, any person applying to the building department for the construction, removal or improvement of any structure shall furnish prior to the issuance of the permit either (i) satisfactory proof to the building official that he is duly licensed or certified under the terms or Chapter 11 (§ 54.1-1000 et seq.) of Title 54.1 of the Code of Virginia to carry out or superintend the same or (ii) file a written statement, supported by an affidavit, that he is not subject to licensure or certification as a contractor or subcontractor pursuant to Chapter 11 of Title 54.1 of the Code of Virginia. The applicant shall also furnish satisfactory proof that the taxes or license fees required by any county, city, or town have been paid so as to be qualified to bid upon or contract for the work for which the permit has been applied.
E. Section 108.5 Mechanics' lien agent designation. In accordance with § 36-98.01 of the Code of Virginia, a building permit issued for any one-family or two-family residential dwelling shall at the time of issuance contain, at the request of the applicant, the name, mailing address, and telephone number of the mechanics' lien agent as defined in § 43-1 of the Code of Virginia. If the designation of a mechanics' lien agent is not so requested by the applicant, the building permit shall at the time of issuance state that none has been designated with the words "None Designated."
Note: In accordance with § 43-4.01A of the Code of Virginia, a permit may be amended after it has been initially issued to name a mechanics' lien agent or a new mechanics' lien agent.
F. Section 108.6 Application form, description of work. The application for a permit shall be submitted on a form or forms supplied by the local building department. The application shall contain a general description and location of the proposed work and such other information as determined necessary by the building official.
G. Section 108.7 Amendments to application. An application for a permit may be amended at any time prior to the completion of the work governed by the permit. Additional construction documents or other records may also be submitted in a like manner. All such submittals shall have the same effect as if filed with the original application for a permit and shall be retained in a like manner as the original filings.
H. Section 108.8 Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned six months after the date of filing unless such application has been pursued in good faith or a permit has been issued, except that the building official is authorized to grant one or more extensions of time if a justifiable cause is demonstrated.
13VAC5-63-110. Section 111 RDP services.
A. Section 111.1 When required. In accordance with § 54.1-410 of the Code of Virginia and under the general authority of this code, the local building department shall establish a procedure to ensure that construction documents under Section 109 are prepared by an RDP in any case in which the exemptions contained in § 54.1-401, 54.1-402 or 54.1-402.1 of the Code of Virginia are not applicable or in any case where the building official determines it necessary. When required under § 54.1-402 of the Code of Virginia or when required by the building official, or both, construction documents shall bear the name and address of the author and his occupation.
Note: Information on the types of construction required to be designed by an RDP is included in the "Related Laws Package" available from DHCD.
B. Section 111.2 Special inspection requirements. Special inspections shall be conducted when required by Section 1704. Individuals or agencies, or both, conducting special inspections shall meet the qualification requirements of Sections 1703 and 1704.1 1704.2.1. The permit applicant shall submit a completed statement of special inspections with the permit application. The building official shall review, and if satisfied that the requirements have been met, approve the statement of special inspections as required in Sections 1704.1.1 1704.2.3 and 1705 as a requisite to the issuance of a building permit. The building official may require interim inspection reports. The building official shall receive, and if satisfied that the requirements have been met, approve a final report of special inspections as specified in Section 1704.1.2 1704.2.4. All fees and costs related to the special inspections shall be the responsibility of the building owner.
13VAC5-63-120. Section 112 Workmanship, materials and equipment.
A. Section 112.1 General. It shall be the duty of any person performing work covered by this code to comply with all applicable provisions of this code and to perform and complete such work so as to secure the results intended by the USBC. Damage to regulated building components caused by violations of this code or by the use of faulty materials or installations shall be considered as separate violations of this code and shall be subject to the applicable provisions of Section 115.
B. Section 112.2 Alternative methods or materials. In accordance with § 36-99 of the Code of Virginia, where practical, the provisions of this code are stated in terms of required level of performance so as to facilitate the prompt acceptance of new building materials and methods. When generally recognized standards of performance are not available, this section and other applicable requirements of this code provide for acceptance of materials and methods whose performance is substantially equal in safety to those specified on the basis of reliable test and evaluation data presented by the proponent. In addition, as a requirement of this code, the building official shall require that sufficient technical data be submitted to substantiate the proposed use of any material, equipment, device, assembly or method of construction.
C. Section 112.3 Documentation and approval. In determining whether any material, equipment, device, assembly or method of construction complies with this code, the building official shall approve items listed by nationally recognized testing laboratories (NRTL), when such items are listed for the intended use and application, and in addition, may consider the recommendations of RDPs. Approval shall be issued when the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code and that the material, equipment, device, assembly or method of construction offered is, for the purpose intended, at least the equivalent of that prescribed by the code. Such approval is subject to all applicable requirements of this code and the material, equipment, device, assembly or method of construction shall be installed in accordance with the conditions of the approval and their listings. In addition, the building official may revoke such approval whenever it is discovered that such approval was issued in error or on the basis of incorrect information, or where there are repeated violations of the USBC.
D. Section 112.3.1 Conditions of listings. Where conflicts between this code and conditions of the listing or the manufacturer's installation instructions occur, the provisions of this code shall apply.
Exception: Where a code provision is less restrictive than the conditions of the listing of the equipment or appliance or the manufacturer's installation instructions, the conditions of the listing and the manufacturer's installation instructions shall apply.
E. Section 112.4 Used material and equipment. Used materials, equipment and devices may be approved provided they have been reconditioned, tested or examined and found to be in good and proper working condition and acceptable for use by the building official.
F. Section 112.5 Defective materials. Notwithstanding any provision of this code to the contrary, where action has been taken and completed by the BHCD under § 36-99 D of the Code of Virginia establishing new performance standards for identified defective materials, this section sets forth the new performance standards addressing the prospective use of such materials and establishes remediation standards for the removal of any defective materials already installed, which, when complied with, enables the building official to certify that the building is deemed to comply with the edition of the USBC under which the building was originally constructed with respect to the remediation of the defective materials. Subsections F through X of this section expire on August 29, 2013.
G. Section 112.5.1 Drywall, performance standard. All newly installed gypsum wallboard shall not be defective drywall as defined in Section 112.5.1.1.1.
H. Section 112.5.1.1 Remediation standards. The following provisions establish remediation standards where defective drywall was installed in buildings.
I. Section 112.5.1.1.1 Definition. For the purposes of this section the term "defective drywall" shall mean gypsum wallboard that (i) contains elemental sulfur exceeding 10 parts per million that when exposed to heat or humidity, or both, emits volatile sulfur compounds in quantities that cause observable corrosion on electrical wiring, plumbing pipes, fuel gas lines, or HVAC equipment, or any components of the foregoing or (ii) has been designated by the U.S. Consumer Product Safety Commission as a product with a product defect that constitutes a substantial product hazard within the meaning of § 15(a)(2) of the Consumer Product Safety Act (15 USC § 2064(a)(2)).
J. Section 112.5.1.1.2 Permit. Application for a permit shall be made to the building official and a permit shall be obtained prior to the commencement of remediation work undertaken to remove defective drywall from a building and for the removal, replacement, or repair of corroded electrical, plumbing, mechanical, or fuel gas equipment and components.
K. Section 112.5.1.1.3 Protocol. Where remediation of defective drywall is undertaken, the following standards shall be met. The building official shall be permitted to consider and approve modifications to these standards in accordance with Section 106.3.
L. Section 112.5.1.1.3.1 Drywall. Drywall in the building, whether defective or nondefective, shall be removed and discarded, including fasteners that held any defective drywall to prevent small pieces of drywall from remaining under fasteners.
Exceptions:
1. Nondefective drywall not subject to the corrosive effects of any defective drywall shall be permitted to be left in place in buildings where the defective drywall is limited to a defined room or space or isolated from the rest of the building and the defective drywall can be positively identified. If the room or space containing the defective drywall also contains any nondefective drywall, the nondefective drywall in that room or space shall also be removed.
2. In multi-family buildings where defective drywall was not used in the firewalls between units and there are no affected building systems behind the firewalls, the firewalls shall be permitted to be left in place.
M. Section 112.5.1.1.3.2 Insulation and other building components. Insulation in walls and ceilings shall be removed and discarded. Carpet and vinyl flooring shall be removed and discarded. Woodwork, trim, cabinets, and tile or wood floors may be left in place or may be reused.
Exceptions:
1. Closed-cell foam insulation is permitted to be left in place if testing for off-gassing from defective drywall is negative, unless its removal is required to gain access.
2. Insulation, carpet, or vinyl flooring in areas not exposed to defective drywall or to the effects of defective drywall, may be left in place or reused.
N. Section 112.5.1.1.3.3 Electrical wiring, equipment, devices, and components. All electrical wiring regulated by this code shall be permitted to be left in place, but removal or cleaning of exposed ends of the wiring to reveal clean or uncorroded surfaces is required. All electrical equipment, devices, and components of the electrical system of the building regulated by this code shall be removed and discarded. This shall include all smoke detectors.
Exceptions:
1. Electrical equipment, devices, or components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused. Electrical equipment, devices, or components in areas exposed to the corrosive effects of defective drywall shall be cleaned, repaired, or replaced.
2. Cord and plug connected appliances are not subject to this code and, therefore, cannot be required to be removed or replaced.
Note: All low voltage wiring associated with security systems, door bells, elevator controls, and other such components shall be removed and replaced or repaired.
O. Section 112.5.1.1.3.4 Plumbing and fuel gas piping, fittings, fixtures, and equipment. All copper fuel gas piping and all equipment utilizing fuel gas with copper, silver, or aluminum components shall be removed and discarded. All copper plumbing pipes and fittings shall be removed and discarded. Plumbing fixtures with copper, silver, or aluminum components shall be removed and discarded.
Exception: Plumbing or fuel gas piping, fittings, fixtures, equipment, or components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused.
P. Section 112.5.1.1.3.5 Mechanical systems. All heating, air-conditioning, and ventilation system components, including, but not limited to, ductwork, air-handling units, furnaces, heat pumps, refrigerant lines, and thermostats and associated wiring, shall be removed and discarded.
Exception: Mechanical system components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused.
Q. Section 112.5.1.1.3.6 Cleaning. Following the removal of all materials and components in accordance with Sections 112.5.1.1.3.1 through 112.5.1.1.3.5, the building shall be thoroughly cleaned to remove any particulate matter and dust.
R. Section 112.5.1.1.3.7 Airing out. Following cleaning in accordance with Section 112.5.1.1.3.6, the building shall be thoroughly aired out with the use of open windows and doors and fans.
S. Section 112.5.1.1.3.8 Pre-rebuilding clearance testing. Following the steps outlined above for removal of all materials and components, cleaning and airing out, a pre-rebuilding clearance test shall be conducted with the use of copper or silver coupons and the methodology outlined in the April 2, 2010, joint report by the Consumer Products Safety Commission and the Department of Housing and Urban Development entitled "Interim Remediation Guidance for Homes with Corrosion from Problem Drywall" or with the use of a copper probe and dosimeter. The clearance testing shall confirm that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report, certifying compliance, shall be submitted to the building official.
Notes:
1. Where the building is served by a well and prior to conducting clearance tests, all outlets in piping served by the well should be capped or otherwise plugged to prevent contamination of the air sample.
2. To prevent siphoning and evaporation of the trap seals, fixtures should be capped or otherwise plugged to prevent sewer gases from contaminating the air sample.
T. Section 112.5.1.1.3.9 Testing agencies and personnel. Agencies and personnel performing pre-rebuilding or post-rebuilding clearance testing shall be independent of those responsible for all other remediation work and the agencies and personnel shall be appropriately certified or accredited by the Council of Engineering and Scientific Specialty Boards, the American Indoor Air Quality Council, or the World Safety Organization.
Exception: Testing agencies and personnel shall be accepted if certified by an RDP or if the agency employs an RDP to be in responsible charge of the work.
U. Section 112.5.1.1.3.10 Rebuilding standards. The rebuilding of the building shall comply with the edition of the USBC that was in effect when the building was originally built.
V. Section 112.5.1.1.3.11 Post-rebuilding clearance testing. A post-rebuilding clearance test prior to reoccupancy of the building or structure shall be conducted with the use of copper or silver coupons and the methodology outlined in the April 2, 2010, joint report by the Consumer Products Safety Commission and by the Department of Housing and Urban Development entitled "Interim Remediation Guidance for Homes with Corrosion from Problem Drywall" or with the use of a copper probe and dosimeter. The clearance testing shall confirm that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report certifying compliance shall be submitted to the building official.
Notes:
1. Where the building is served by a well and prior to conducting clearance tests, all outlets in piping served by the well should be capped or otherwise plugged to prevent contamination of the air sample.
2. To prevent siphoning and evaporation of the trap seals, fixtures should be capped or otherwise plugged to prevent sewer gases from contaminating the air sample.
W. Section 112.5.1.1.4 Final approval by the building official. Once remediation has been completed in accordance with this section, a certificate or letter of approval shall be issued by the building official. The certificate or letter shall state that the remediation and rebuilding is deemed to comply with this code.
X. Section 112.5.1.1.4.1 Approval of remediation occurring prior to these standards. The building official shall issue a certificate or letter of approval for remediation of defective drywall that occurred prior to the effective date of these standards provided post-rebuilding clearance testing has been performed in accordance with Section 112.5.1.1.3.11, by agencies and personnel complying with Section 112.5.1.1.3.9, and the clearance testing confirms that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report certifying compliance shall be submitted to the building official.
F. Section 112.5 Defective materials. Notwithstanding any provision of this code to the contrary, where action has been taken and completed by the BHCD under subsection D of § 36-99 of the Code of Virginia establishing new performance standards for identified defective materials, this section sets forth the new performance standards addressing the prospective use of such materials and establishes remediation standards for the removal of any defective materials already installed, which when complied with enables the building official to certify that the building is deemed to comply with the edition of the USBC under which the building was originally constructed with respect to the remediation of the defective materials.
G. Section 112.5.1 Drywall, performance standard. All newly installed gypsum wallboard shall not be defective drywall as defined in Section 112.5.1.1.1.
H. Section 112.5.1.1 Remediation standards. The following provisions establish remediation standards where defective drywall was installed in buildings.
I. Section 112.5.1.1.1 Definition. For the purposes of this section the term "defective drywall" means gypsum wallboard that (i) contains elemental sulfur exceeding 10 parts per million that when exposed to heat or humidity, or both, emits volatile sulfur compounds in quantities that cause observable corrosion on electrical wiring, plumbing pipes, fuel gas lines, or HVAC equipment, or any components of the foregoing or (ii) has been designated by the U.S. Consumer Product Safety Commission as a product with a product defect that constitutes a substantial product hazard within the meaning of § 15(a)(2) of the Consumer Product Safety Act (15 USC § 2064(a)(2)).
J. Section 112.5.1.1.2 Permit. Application for a permit shall be made to the building official, and a permit shall be obtained prior to the commencement of remediation work undertaken to remove defective drywall from a building and for the removal, replacement, or repair of corroded electrical, plumbing, mechanical, or fuel gas equipment and components.
K. Section 112.5.1.1.3 Protocol. Where remediation of defective drywall is undertaken, the following standards shall be met. The building official shall be permitted to consider and approve modifications to these standards in accordance with Section 106.3.
L. Section 112.5.1.1.3.1 Drywall. Drywall in the building, whether defective or nondefective, shall be removed and discarded, including fasteners that held any defective drywall to prevent small pieces of drywall from remaining under fasteners.
Exceptions:
1. Nondefective drywall not subject to the corrosive effects of any defective drywall shall be permitted to be left in place in buildings where the defective drywall is limited to a defined room or space or isolated from the rest of the building and the defective drywall can be positively identified. If the room or space containing the defective drywall also contains any nondefective drywall, the nondefective drywall in that room or space shall also be removed.
2. In multifamily buildings where defective drywall was not used in the firewalls between units and there are no affected building systems behind the firewalls, the firewalls shall be permitted to be left in place.
M. Section 112.5.1.1.3.2 Insulation and other building components. Insulation in walls and ceilings shall be removed and discarded. Carpet and vinyl flooring shall be removed and discarded. Woodwork, trim, cabinets, and tile or wood floors may be left in place or may be reused.
Exceptions:
1. Closed-cell foam insulation is permitted to be left in place if testing for off-gassing from defective drywall is negative, unless its removal is required to gain access.
2. Insulation, carpet, or vinyl flooring in areas not exposed to defective drywall or to the effects of defective drywall, may be left in place or reused.
N. Section 112.5.1.1.3.3 Electrical wiring, equipment, devices, and components. All electrical wiring regulated by this code shall be permitted to be left in place, but removal or cleaning of exposed ends of the wiring to reveal clean or uncorroded surfaces is required. All electrical equipment, devices, and components of the electrical system of the building regulated by this code shall be removed and discarded. This shall include all smoke detectors.
Exceptions:
1. Electrical equipment, devices, or components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused. Electrical equipment, devices, or components in areas exposed to the corrosive effects of defective drywall shall be cleaned, repaired, or replaced.
2. Cord and plug connected appliances are not subject to this code and, therefore, cannot be required to be removed or replaced.
Note: All low-voltage wiring associated with security systems, door bells, elevator controls, and other such components shall be removed and replaced or repaired.
O. Section 112.5.1.1.3.4 Plumbing and fuel gas piping, fittings, fixtures, and equipment. All copper fuel gas piping and all equipment utilizing fuel gas with copper, silver, or aluminum components shall be removed and discarded. All copper plumbing pipes and fittings shall be removed and discarded. Plumbing fixtures with copper, silver, or aluminum components shall be removed and discarded.
Exception: Plumbing or fuel gas piping, fittings, fixtures, equipment, or components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused.
P. Section 112.5.1.1.3.5 Mechanical systems. All heating, air-conditioning, and ventilation system components, including but not limited to ductwork, air-handling units, furnaces, heat pumps, refrigerant lines, and thermostats and associated wiring, shall be removed and discarded.
Exception: Mechanical system components in areas not exposed to the corrosive effects of defective drywall shall be permitted to be left in place or reused.
Q. Section 112.5.1.1.3.6 Cleaning. Following the removal of all materials and components in accordance with Sections 112.5.1.1.3.1 through 112.5.1.1.3.5, the building shall be thoroughly cleaned to remove any particulate matter and dust.
R. Section 112.5.1.1.3.7 Airing out. Following cleaning in accordance with Section 112.5.1.1.3.6, the building shall be thoroughly aired out with the use of open windows and doors and fans.
S. Section 112.5.1.1.3.8 Pre-rebuilding clearance testing. Following the steps outlined above for removal of all materials and components, cleaning and airing out, a pre-rebuilding clearance test shall be conducted with the use of copper or silver coupons and the methodology outlined in the April 2, 2010, joint report by the Consumer Products Safety Commission and the Department of Housing and Urban Development "Interim Remediation Guidance for Homes with Corrosion from Problem Drywall" or with the use of a copper probe and dosimeter. The clearance testing shall confirm that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report, certifying compliance, shall be submitted to the building official.
Notes:
1. Where the building is served by a well and prior to conducting clearance tests, all outlets in piping served by the well should be capped or otherwise plugged to prevent contamination of the air sample.
2. To prevent siphoning and evaporation of the trap seals, fixtures should be capped or otherwise plugged to prevent sewer gases from contaminating the air sample.
T. Section 112.5.1.1.3.9 Testing agencies and personnel. Agencies and personnel performing pre-rebuilding or post-rebuilding clearance testing shall be independent of those responsible for all other remediation work and the agencies and personnel shall be appropriately certified or accredited by the Council of Engineering and Scientific Specialty Boards, the American Indoor Air Quality Council, or the World Safety Organization.
Exception: Testing agencies and personnel shall be accepted if certified by an RDP or if the agency employs an RDP to be in responsible charge of the work.
U. Section 112.5.1.1.3.10 Rebuilding standards. The rebuilding of the building shall comply with the edition of the USBC that was in effect when the building was originally built.
V. Section 112.5.1.1.3.11 Post-rebuilding clearance testing. A post-rebuilding clearance test prior to reoccupancy of the building or structure shall be conducted with the use of copper or silver coupons and the methodology outlined in the April 2, 2010, joint report by the Consumer Products Safety Commission and by the Department of Housing and Urban Development "Interim Remediation Guidance for Homes with Corrosion from Problem Drywall" or with the use of a copper probe and dosimeter. The clearance testing shall confirm that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report certifying compliance shall be submitted to the building official.
Notes:
1. Where the building is served by a well and prior to conducting clearance tests, all outlets in piping served by the well should be capped or otherwise plugged to prevent contamination of the air sample.
2. To prevent siphoning and evaporation of the trap seals, fixtures should be capped or otherwise plugged to prevent sewer gases from contaminating the air sample.
W. Section 112.5.1.1.4 Final approval by the building official. Once remediation has been completed in accordance with this section, a certificate or letter of approval shall be issued by the building official. The certificate or letter shall state that the remediation and rebuilding is deemed to comply with this code.
X. Section 112.5.1.1.4.1 Approval of remediation occurring prior to these standards. The building official shall issue a certificate or letter of approval for remediation of defective drywall that occurred prior to the effective date of these standards provided post-rebuilding clearance testing has been performed in accordance with Section 112.5.1.1.3.11, by agencies and personnel complying with Section 112.5.1.1.3.9, and the clearance testing confirms that all airborne compounds associated with the defective drywall are at usual environmental background levels. The clearance testing report certifying compliance shall be submitted to the building official.
13VAC5-63-130. Section 113 Inspections.
A. Section 113.1 General. In accordance with § 36-105 of the Code of Virginia, any building or structure may be inspected at any time before completion, and shall not be deemed in compliance until approved by the inspecting authority. Where the construction cost is less than $2,500, however, the inspection may, in the discretion of the inspecting authority, be waived. The building official shall coordinate all reports of inspections for compliance with the USBC, with inspections of fire and health officials delegated such authority, prior to the issuance of an occupancy permit.
B. Section 113.1.1 Equipment required. Any ladder, scaffolding or test equipment necessary to conduct or witness a requested inspection shall be provided by the permit holder.
C. Section 113.1.2 Duty to notify. When construction reaches a stage of completion that requires an inspection, the permit holder shall notify the building official.
D. Section 113.1.3 Duty to inspect. Except as provided for in Section 113.7, the building official shall perform the requested inspection in accordance with Section 113.6 when notified in accordance with Section 113.1.2.
E. Section 113.2 Prerequisites. The building official may conduct a site inspection prior to issuing a permit. When conducting inspections pursuant to this code, all personnel shall carry proper credentials.
F. Section 113.3 Minimum inspections. The following minimum inspections shall be conducted by the building official when applicable to the construction or permit:
1. Inspection of footing excavations and reinforcement material for concrete footings prior to the placement of concrete.
2. Inspection of foundation systems during phases of construction necessary to assure compliance with this code.
3. Inspection of preparatory work prior to the placement of concrete.
4. Inspection of structural members and fasteners prior to concealment.
5. Inspection of electrical, mechanical and plumbing materials, equipment and systems prior to concealment.
6. Inspection of energy conservation material prior to concealment.
7. Final inspection.
G. Section 113.4 Additional inspections. The building official may designate additional inspections and tests to be conducted during the construction of a building or structure and shall so notify the permit holder.
H. Section 113.5 In-plant and factory inspections. When required by the provisions of this code, materials, equipment or assemblies shall be inspected at the point of manufacture or fabrication. The building official shall require the submittal of an evaluation report of such materials, equipment or assemblies. The evaluation report shall indicate the complete details of the assembly including a description of the assembly and its components, and describe the basis upon which the assembly is being evaluated. In addition, test results and other data as necessary for the building official to determine conformance with the USBC shall be submitted. For factory inspections, an identifying label or stamp permanently affixed to materials, equipment or assemblies indicating that a factory inspection has been made shall be acceptable instead of a written inspection report, provided the intent or meaning of such identifying label or stamp is properly substantiated.
I. Section 113.6 Approval or notice of defective work. The building official shall either approve the work in writing or give written notice of defective work to the permit holder. Upon request of the permit holder, the notice shall reference the USBC section that serves as the basis for the defects and such defects shall be corrected and reinspected before any work proceeds that would conceal such defects. A record of all reports of inspections, tests, examinations, discrepancies and approvals issued shall be maintained by the building official and shall be communicated promptly in writing to the permit holder. Approval issued under this section may be revoked whenever it is discovered that such approval was issued in error or on the basis of incorrect information, or where there are repeated violations of the USBC. Notices issued pursuant to this section shall be permitted to be communicated electronically, provided the notice is reasonably calculated to get to the permit holder.
J. Section 113.7 Approved inspection agencies. The building official may accept reports of inspections and tests from individuals or inspection agencies approved in accordance with the building official's written policy required by Section 113.7.1. The individual or inspection agency shall meet the qualifications and reliability requirements established by the written policy. Under circumstances where the building official is unable to make the inspection or test required by Section 113.3 or 113.4 within two working days of a request or an agreed upon date or if authorized for other circumstances in the building official's written policy, the building official shall accept reports for review. The building official shall approve the report from such approved individuals or agencies unless there is cause to reject it. Failure to approve a report shall be in writing within two working days of receiving it stating the reason for the rejection. Reports of inspections conducted by approved third-party inspectors or agencies shall be in writing, shall indicate if compliance with the applicable provisions of the USBC have been met and shall be certified by the individual inspector or by the responsible officer when the report is from an agency.
Note: Photographs, videotapes or other sources of pertinent data or information may be considered as constituting such reports and tests.
K. Section 113.7.1 Third-party inspectors. Each building official charged with the enforcement of the USBC shall have a written policy establishing the minimum acceptable qualifications for third-party inspectors. The policy shall include the format and time frame required for submission of reports, any prequalification or preapproval requirements before conducting a third-party inspection and any other requirements and procedures established by the building official.
L. Section 113.7.2 Qualifications. In determining third-party inspector qualifications, the building official may consider such items as DHCD inspector certification, other state or national certifications, state professional registrations, related experience, education and any other factors that would demonstrate competency and reliability to conduct inspections.
M. Section 113.8 Final inspection. Upon completion of a building or structure and before the issuance of a certificate of occupancy, a final inspection shall be conducted to ensure that any defective work has been corrected and that all work complies with the USBC and has been approved, including any work associated with modifications under Section 106.3. The building official shall be permitted to require the electrical service to a building or structure to be energized prior to conducting the final inspection. The approval of a final inspection shall be permitted to serve as the new certificate of occupancy required by Section 116.1 in the case of additions or alterations to existing buildings or structures that already have a certificate of occupancy.
13VAC5-63-160. Section 116 Certificates of occupancy.
A. Section 116.1 General; when to be issued. A certificate of occupancy indicating completion of the work for which a permit was issued shall be obtained prior to the occupancy of any building or structure, except as provided for in this section generally and as specifically provided for in Section 113.8 for additions or alterations. The certificate shall be issued after completion of the final inspection and when the building or structure is in compliance with this code and any pertinent laws or ordinances, or when otherwise entitled. The building official shall, however, issue a certificate of occupancy within five working days after being requested to do so, provided the building or structure meets all of the requirements for a certificate.
Exception: A certificate of occupancy is not required for an accessory structure as defined in the International Residential Code IRC.
B. Section 116.1.1 Temporary certificate of occupancy. Upon the request of a permit holder, a temporary certificate of occupancy may be issued before the completion of the work covered by a permit, provided that such portion or portions of a building of structure may be occupied safely prior to full completion of the building or structure without endangering life or public safety.
C. Section 116.2 Contents of certificate. A certificate of occupancy shall specify the following:
1. The edition of the USBC under which the permit is issued.
2. The group classification and occupancy in accordance with the provisions of Chapter 3.
3. The type of construction as defined in Chapter 6.
4. If an automatic sprinkler system is provided and whether or not such system was required.
5. Any special stipulations and conditions of the building permit and if any modifications were issued under the permit, there shall be a notation on the certificate that modifications were issued.
6. Group R-5 occupancies complying with Section R320.2 of the IRC shall have a notation of compliance with that section on the certificate.
D. Section 116.3 Suspension or revocation of certificate. A certificate of occupancy may be revoked or suspended whenever the building official discovers that such certificate was issued in error or on the basis of incorrect information, or where there are repeated violations of the USBC after the certificate has been issued or when requested by the code official under Section 105.7 of the Virginia Maintenance Code VMC. The revocation or suspension shall be in writing and shall state the necessary corrections or conditions for the certificate to be reissued or reinstated in accordance with Section 116.3.1.
E. Section 116.3.1 Reissuance [ of or ] reinstatement of certificate of occupancy. When a certificate of occupancy has been revoked or suspended, it shall be reissued or reinstated upon correction of the specific condition or conditions cited as the cause of the revocation or suspension and the revocation or suspension of a certificate of occupancy shall not be used as justification for requiring a building or structure to be subject to a later edition of the code than that under which such building or structure was initially constructed.
F. Section 116.4 Issuance of certificate for pre-USBC buildings or structures. When a building or structure was constructed prior to being subject to the initial edition of the USBC and the local building department does not have a certificate of occupancy for the building or structure, the owner or owner's agent may submit a written request for a certificate to be created. The building official, after receipt of the request, shall issue a certificate provided a determination is made that there are no current violations of the Virginia Maintenance Code VMC or the Virginia Statewide Fire Prevention Code (13VAC5-51) and the occupancy classification of the building or structure has not changed. Such buildings and structures shall not be prevented from continued use.
Exception: When no certificate exists, but the local building department has records indicating that a certificate did exist, then the building official may either verify in writing that a certificate did exist or issue a certificate based upon the records.
13VAC5-63-170. Section 117 Temporary and moved buildings and structures; demolition.
A. Section 117.1 Temporary [ building buildings ] and structures. The building official is authorized to issue a permit for temporary buildings or structures. Such permits shall be limited as to time of service, but shall not be permitted for more than one year, except that upon the permit holder's written request, the building official may grant one or more extensions of time, not to exceed one year per extension. The building official is authorized to terminate the approval and order the demolition or removal of temporary buildings or structures during the period authorized by the permit when determined necessary.
B. Section 117.1.1 Temporary uses within existing buildings and structures. The building official shall review and may approve conditions or modifications for temporary uses, including hypothermia and hyperthermia shelters, that may be necessary as long as the use meets the spirit and functional intent intended by this code. The building official is authorized to terminate the approval and order the discontinuance of the temporary use during the period authorized by the permit when determined necessary. The building official shall notify the appropriate fire official or fire chief of the approved temporary use.
B. C. Section 117.2 Moved buildings and structures. Any building or structure moved into a locality or moved to a new location within a locality shall not be occupied or used until a certification of occupancy is issued for the new location. Such moved buildings or structures shall be required to comply with the requirements of this code for a newly constructed building or structure unless meeting all of the following requirements relative to the new location:
1. There is no change in the occupancy classification from its previous location.
2. The building or structure was in compliance with all state and local requirements applicable to it in its previous location and is in compliance with all state and local requirements applicable if originally constructed in the new location.
3. The building or structure did not become unsafe during the moving process due to structural damage or for other reasons.
4. Any alterations, reconstruction, renovations or repairs made pursuant to the move are in compliance with applicable requirements of this code the VRC.
C. D. Section 117.3 Demolition of buildings and structures. Prior to the issuance of a permit for the demolition of any building or structure, the owner or the owner's agent shall provide certification to the building official that all service connections of utilities have been removed, sealed or plugged satisfactorily and a release has been obtained from the associated utility company. The certification shall further provide that written notice has been given to the owners of adjoining lots and any other lots that may be affected by the temporary removal of utility wires or the temporary disconnection or termination of other services or facilities relative to the demolition. In addition, the requirements of Chapter 33 of the IBC for any necessary retaining walls or fences during demolition shall be applicable and when a building or structure is demolished or removed, the established grades shall be restored.
13VAC5-63-180. Section 118 Buildings and Unsafe buildings or structures becoming unsafe during construction.
A. Section 118.1 Applicability. This section applies to unsafe buildings and or structures for which a construction permit has been issued under this code and construction has not been completed or a certificate of occupancy has not been issued, or both. In addition, this section applies to any building or structure that is under construction or that was constructed without obtaining the required permits under this edition or any edition of the USBC.
Note: Existing buildings and structures other than those under construction or subject to this section are subject to the Virginia Maintenance Code that VMC, which also has requirements for unsafe conditions.
B. Section 118.2 Repair or removal of unsafe buildings or structures. Any unsafe building or structure subject to this section that is either deteriorated, improperly maintained, of faulty construction, deficient in adequate exit facilities, a fire hazard or dangerous to life or the public welfare, or both, or any combination of the foregoing, is an unsafe building or structure and shall be made safe through compliance with this code or shall be taken down and removed if determined necessary by the building official.
C. Section 118.3 Inspection report and notice of unsafe building or structure. The building official shall inspect any reported unsafe building or structure reported to be unsafe and shall prepare a report to be filed in the records of the local building department. In addition to a description of any unsafe conditions found, the report shall include the occupancy classification of the building or structure and the nature and extent of any damages caused by collapse or failure of any building components. If the
D. Section 118.4 Notice of unsafe building or structure. When a building or structure is determined by the building official to be an unsafe building or structure, a written notice of unsafe building or structure shall be issued in person by personal service to the owner and any permit holder, the owner's agent, or the person in control of such building or structure. The notice shall describe any unsafe conditions and specify any repairs or improvements the corrections necessary to make the building or structure safe, or alternatively, when determined necessary by the building official, require the unsafe building or structure, or any portion of it, to be taken down and removed. The notice shall stipulate a comply with this code and specify the time period within which the repairs must occur, or if the notice specifies that the unsafe building or structure is required to be demolished, the notice shall specify the time period for the repair or within which demolition of the unsafe building or structure and contain a statement requiring the person receiving the notice to determine whether to accept or reject the terms of the notice. If any persons to which the notice of unsafe building or structure is to be issued cannot be found after diligent search, as equivalent service, the notice shall be sent by registered or certified mail to the last known address of such persons and a copy of the notice posted in a conspicuous place on the premises must occur.
Note: Whenever possible, the notice should also be given to any tenants or occupants of the unsafe building or structure.
D. E. Section 118.4 118.4.1 Vacating the unsafe building or structure. If any portion of an unsafe building or structure has collapsed or fallen, or if the building official determines there is actual and immediate danger of any portion collapsing or falling, and to the occupants or public, or when life is endangered by the occupancy of the an unsafe building or structure, the building official shall be authorized to order the occupants to immediately vacate the unsafe building or structure. When an unsafe building or structure is ordered to be vacated, the building official shall post a notice at each entrance that reads as follows:
"This Building (or Structure) is Unsafe and its Occupancy (or Use) is Prohibited by the Building Official."
After posting, occupancy or use of the unsafe building or structure shall be prohibited except when authorized to enter to conduct inspections, make required repairs, or as necessary to demolish the building or structure.
E. F. Section 118.5 Posting of notice. If the notice is unable to be issued by personal service as required by Section 118.4, then the notice shall be sent by registered or certified mail to the last known address of the responsible party and a copy of the notice shall be posted in a conspicuous place on the premises.
G. Section 118.6 Posting of placard. In the case of an unsafe building or structure, if the notice is not complied with, a placard with the following wording shall be posted at the entrance to the building or structure:
"This Building (or Structure) is Unfit for Habitation and its Use or Occupancy has been Prohibited by the Building Official."
After an unsafe building or structure is placarded, entering the unsafe building or structure shall be prohibited except as authorized by the building official to make inspections, to perform required repairs, or to demolish the unsafe building or structure. In addition, the placard shall not be removed until the unsafe building or structure is determined by the building official to be safe to occupy. The placard shall not be defaced.
H. Section 118.7 Emergency repairs and demolition. To the extent permitted by the locality, the building official may authorize emergency repairs to unsafe buildings or structures when it is determined that there is an immediate danger of any portion of the unsafe building or structure collapsing or falling and when life is endangered. Emergency repairs may also be authorized when there is a code violation resulting in the immediate, a serious and imminent threat to the life and safety of the occupants or public. The building official shall be permitted to authorize the necessary work to make the unsafe building or structure temporarily safe whether or not legal action to compel compliance has been instituted.
In addition, whenever an owner of an unsafe building or structure fails to comply with a notice to demolish issued under Section 118.3 118.4 in the time period stipulated, the building official shall be permitted to cause the unsafe building or structure to be demolished. In accordance with §§ 15.2-906 and 15.2-1115 of the Code of Virginia, the legal counsel of the locality may be requested to institute appropriate action against the property owner to recover the costs associated with any such emergency repairs or demolition and every such charge that remains unpaid shall constitute a lien against the property on which the emergency repairs or demolition were made and shall be enforceable in the same manner as provided in Articles 3 (§ 58.1-3940 et seq.) and 4 (§ 58.1-3965 et seq.) of Chapter 39 of Title 58.1 of the Code of Virginia.
Note: Building officials and local governing bodies should be aware that other statutes and court decisions may impact on matters relating to demolition, in particular whether newspaper publication is required if the owner cannot be located and whether the demolition order must be delayed until the owner has been given the opportunity for a hearing.
I. Section 118.8 Closing of streets. When necessary for public safety, the building official shall be permitted to order the temporary closing of sidewalks, streets, public ways, or premises adjacent to unsafe buildings or structures and prohibit the use of such spaces.
13VAC5-63-190. Section 119 Appeals.
A. Section 119.1 Establishment of appeals board. In accordance with § 36-105 of the Code of Virginia, there shall be established within each local building department a LBBCA. Whenever a county or a municipality does not have such a LBBCA, the local governing body shall enter into an agreement with the local governing body of another county or municipality or with some other agency, or a state agency approved by DHCD for such appeals resulting therefrom. Fees may be levied by the local governing body in order to defray the cost of such appeals. In addition, as an authorization in this code, separate LBBCAs may be established to hear appeals of different enforcement areas such as electrical, plumbing or mechanical requirements. Each such LBBCA shall comply with the requirements of this section. The locality is responsible for maintaining a duly constituted LBBCA prepared to hear appeals within the time limits established in this section. The LBBCA shall meet as necessary to assure a duly constituted board, appoint officers as necessary, and receive such training on the code as may be appropriate or necessary from staff of the locality.
B. Section 119.2 Membership of board. The LBBCA shall consist of at least five members appointed by the locality for a specific term of office established by written policy. Alternate members may be appointed to serve in the absence of any regular members and as such, shall have the full power and authority of the regular members. Regular and alternate members may be reappointed. Written records of current membership, including a record of the current chairman and secretary shall be maintained in the office of the locality. In order to provide continuity, the terms of the members may be of different length so that less than half will expire in any one-year period. The LBBCA shall meet at least once annually to assure a duly constituted board, appoint officers as necessary, and receive such training on the code as may be appropriate or necessary from staff of the locality.
C. Section 119.3 Officers and qualifications of members. The LBBCA shall annually select one of its regular members to serve as chairman. When the chairman is not present at an appeal hearing, the members present shall select an acting chairman. The locality or the chief executive officer of the locality shall appoint a secretary to the LBBCA to maintain a detailed record of all proceedings. Members of the LBBCA shall be selected by the locality on the basis of their ability to render fair and competent decisions regarding application of the USBC and shall to the extent possible, represent different occupational or professional fields relating to the construction industry. At least one member should be an experienced builder; at least one member should be an RDP, and at least one member should be an experienced property manager. Employees or officials of the locality shall not serve as members of the LBBCA.
D. Section 119.4 Conduct of members. No member shall hear an appeal in which that member has a conflict of interest in accordance with the State and Local Government Conflict of Interests Act (§ 2.2-3100 et seq. of the Code of Virginia). Members shall not discuss the substance of an appeal with any other party or their representatives prior to any hearings.
E. Section 119.5 Right of appeal; filing of appeal application. Any person aggrieved by the local building department's application of the USBC or the refusal to grant a modification to the provisions of the USBC may appeal to the LBBCA. The applicant shall submit a written request for appeal to the LBBCA within 30 calendar days of the receipt of the decision being appealed. The application shall contain the name and address of the owner of the building or structure and in addition, the name and address of the person appealing, when the applicant is not the owner. A copy of the building official's decision shall be submitted along with the application for appeal and maintained as part of the record. The application shall be marked by the LBBCA to indicate the date received. Failure to submit an application for appeal within the time limit established by this section shall constitute acceptance of a building official's decision.
Note: To the extent that a decision of a building official pertains to amusement devices there may be a right of appeal under the VADR.
F. Section 119.6 Meetings and postponements. The LBBCA shall meet within 30 calendar days after the date of receipt of the application for appeal, except that a period of up to 45 calendar days shall be permitted where the LBBCA has regularly scheduled monthly meetings. A longer time period shall be permitted if agreed to by all the parties involved in the appeal. A notice indicating the time and place of the hearing shall be sent to the parties in writing to the addresses listed on the application at least 14 calendar days prior to the date of the hearing, except that a lesser time period shall be permitted if agreed to by all the parties involved in the appeal. When a quorum of the LBBCA is not present at a hearing to hear an appeal, any party involved in the appeal shall have the right to request a postponement of the hearing. The LBBCA shall reschedule the appeal within 30 calendar days of the postponement, except that a longer time period shall be permitted if agreed to by all the parties involved in the appeal.
G. Section 119.7 Hearings and decision. All hearings before the LBBCA shall be open meetings and the appellant, the appellant's representative, the locality's representative and any person whose interests are affected by the building official's decision in question shall be given an opportunity to be heard. The chairman shall have the power and duty to direct the hearing, rule upon the acceptance of evidence and oversee the record of all proceedings. The LBBCA shall have the power to uphold, reverse or modify the decision of the official by a concurring vote of a majority of those present. Decisions of the LBBCA shall be final if no further appeal is made. The decision of the LBBCA shall be by resolution signed by the chairman and retained as part of the record of the appeal. Copies of the resolution shall be sent to all parties by certified mail. In addition, the resolution shall contain the following wording:
"Any person who was a party to the appeal may appeal to the State Review Board by submitting an application to such Board within 21 calendar days upon receipt by certified mail of this resolution. Application forms are available from the Office of the State Review Board, 600 East Main Street, Richmond, Virginia 23219, (804) 371-7150."
H. Section 119.8 Appeals to the State Review Board. After final determination by the LBBCA in an appeal, any person who was a party to the appeal may further appeal to the State Review Board. In accordance with § 36-98.2 of the Code of Virginia for state-owned buildings and structures, appeals by an involved state agency from the decision of the building official for state-owned buildings or structures shall be made directly to the State Review Board. The application for appeal shall be made to the State Review Board within 21 calendar days of the receipt of the decision to be appealed. Failure to submit an application within that time limit shall constitute an acceptance of the building official's decision. For appeals from a LBBCA, a copy of the building official's decision and the resolution of the LBBCA shall be submitted with the application for appeal to the State Review Board. Upon request by the office of the State Review Board, the LBBCA shall submit a copy of all pertinent information from the record of the appeal. In the case of appeals involving state-owned buildings or structures, the involved state agency shall submit a copy of the building official's decision and other relevant information with the application for appeal to the State Review Board. Procedures of the State Review Board are in accordance with Article 2 (§ 36-108 et seq.) of Chapter 6 of Title 36 of the Code of Virginia. Decisions of the State Review Board shall be final if no further appeal is made.
13VAC5-63-200. Chapter 2 Definitions: Section 202 Definitions.
A. Add the following definitions to Section 202 of the IBC to read:
Aboveground liquid fertilizer storage tank (ALFST). A device that contains an accumulation of liquid fertilizer (i) constructed of nonearthen materials, such as concrete, steel or plastic, that provide structural support; (ii) having a capacity of 100,000 gallons (378 500 L) or greater; and (iii) the volume of which is more than 90% above the surface of the ground. The term does not include any wastewater treatment or wastewater storage tank, utility or industry pollution control equipment.
Building regulations. Any law, rule, resolution, regulation, ordinance or code, general or special, or compilation thereof, heretofore or hereafter enacted or adopted by the Commonwealth or any county or municipality, including departments, boards, bureaus, commissions, or other agencies thereof, relating to construction, reconstruction, alteration, conversion, repair, maintenance, or use of structures and buildings and installation of equipment therein. The term does not include zoning ordinances or other land use controls that do not affect the manner of construction or materials to be used in the erection, alteration or repair of a building or structure.
Change of occupancy. A change in the use or occupancy of any building or structure which that would place the building or structure in a different division of the same group of occupancies or in a different group of occupancies; or a change in the purpose or level of activity within a building or structure that involves a change in application of the requirements of this code.
Construction. The construction, reconstruction, alteration, repair, or conversion of buildings and structures.
Day-night average sound level (Ldn). See Section 1202.1 A 24-hour energy average sound level expressed in dBA, with a 10 decibel penalty applied to noise occurring between 10 p.m. and 7 a.m.
DHCD. The Virginia Department of Housing and Community Development.
Emergency communication equipment. See Section 902.1 Emergency communication equipment, includes but is not limited to two-way radio communications, signal booster, bi-directional amplifiers, radiating cable systems, or internal multiple antenna, or a combination of the foregoing.
Emergency public safety personnel. See Section 902.1 Emergency public safety personnel includes firefighters, emergency medical personnel, law-enforcement officers, and other emergency public safety personnel routinely called upon to provide emergency assistance to members of the public in a wide variety of emergency situations, including but not limited to fires, medical emergencies, violent crimes, and terrorist attacks.
Equipment. Plumbing, heating, electrical, ventilating, air-conditioning and refrigeration equipment, elevators, dumbwaiters, escalators, and other mechanical additions or installations.
Farm building or structure. A building or structure not used for residential purposes, located on property where farming operations take place, and used primarily for any of the following uses or combination thereof:
1. Storage, handling, production, display, sampling or sale of agricultural, horticultural, floricultural or silvicultural products produced in the farm.
2. Sheltering, raising, handling, processing or sale of agricultural animals or agricultural animal products.
3. Business or office uses relating to the farm operations.
4. Use of farm machinery or equipment or maintenance or storage of vehicles, machinery or equipment on the farm.
5. Storage or use of supplies and materials used on the farm.
6. Implementation of best management practices associated with farm operations.
Hospice facility. An institution, place, or building owned or operated by a hospice provider and licensed by the Virginia Department of Health as a hospice facility to provide room, board, and palliative and supportive medical and other health services to terminally ill patients and their families, including respite and symptom management, on a 24-hour basis to individuals requiring such care pursuant to the orders of a physician.
Industrialized building. A combination of one or more sections or modules, subject to state regulations and including the necessary electrical, plumbing, heating, ventilating and other service systems, manufactured off-site and transported to the point of use for installation or erection, with or without other specified components, to comprise a finished building. Manufactured homes shall not be considered industrialized buildings for the purpose of this code.
Hospice facility. See Section 308.3.1.
LBBCA. Local board of building code appeals.
Liquid fertilizer. A fluid in which a fertilizer is in true solution. This term does not include anhydrous ammonia or a solution used in pollution control.
Local building department. The agency or agencies of any local governing body charged with the administration, supervision, or enforcement of this code, approval of construction documents, inspection of buildings or structures, or issuance of permits, licenses, certificates or similar documents.
Local governing body. The governing body of any city, county or town in this Commonwealth.
Locality. A city, county or town in this Commonwealth.
Manufactured home. A structure subject to federal regulation, which is transportable in one or more sections; is eight body feet or more in width and 40 body feet or more in length in the traveling mode, or is 320 or more square feet when erected on site; is built on a permanent chassis; is designed to be used as a single-family dwelling, with or without a permanent foundation, when connected to the required utilities; and includes the plumbing, heating, air-conditioning, and electrical systems contained in the structure.
Marina. Any installation, operating under public or private ownership, that has a structure providing dockage or moorage for boats, other than paddleboats or rowboats, and provides, through sale, rental, fee, or on a free basis, any equipment, supply, or service, including fuel, electricity, or water, for the convenience of the public or its lessees, renters, or users of its facilities. A dock or pier with or without slips that exclusively serves a single-family residential lot for the use of the owner of the lot is not a marina.
Night club. Any building in which the main use is a place of public assembly that provides exhibition, performance or other forms of entertainment; serves alcoholic beverages; and provides music and space for dancing.
[ Permissible fireworks. Any sparklers, fountains, Pharaoh's serpents, caps for pistols, or pinwheels commonly known as whirligigs or spinning jennies.
Short-term holding area. An area containing a holding cell or cells, or a holding room or rooms, including associated rooms or spaces where the occupants are restrained or detained by the use of security measures not under the occupant's control for less than 24 hours. ]
Skirting. A weather-resistant material used to enclose the space from the bottom of the manufactured home to grade.
Slip. A berth or space where a boat may be secured to a fixed or floating structure, including a dock, finger pier, boat lift, or mooring buoy.
Sound transmission class (STC) rating. See Section 1202.1 A single number characterizing the sound reduction performance of a material tested in accordance with ASTM E90-90, "Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions."
State regulated care facility (SRCF). A building with an occupancy in Group R-2, R-3, R-4 or R-5 occupied by persons in the care of others where program oversight is provided by the Virginia Department of Social Services, the Virginia Department of Behavioral Health and Developmental Services, the Virginia Department of Education or the Virginia Department of Juvenile Justice.
State Review Board. The Virginia State Building Code Technical Review Board as established under § 36-108 of the Code of Virginia.
Technical assistant. Any person employed by or under an extended contract to a local building department or local enforcing agency for enforcing the USBC, including but not limited to inspectors and plans reviewers. For the purpose of this definition, an extended contract shall be a contract with an aggregate term of 18 months or longer.
Technical production area. See Section 410.2.
Tenable environmental. An environment in which the products of combustion, including smoke, toxic gases, particulates, and heat, are limited or otherwise restricted in order to maintain the impact on occupants, including those in the area of fire origin, to a level that is not life threatening and permits the rescue of occupants for a limited time.
Unsafe building or structure. Any building or structure that is under construction and has not received a permanent certificate of occupancy, final inspection, or for which a permit was never issued or has expired and has been determined by the building official to be of faulty construction that is so damaged, decayed, dilapidated, structurally unsafe, or of such faulty construction or unstable foundation that partial or complete collapse is likely, or any unfinished construction that does not have a valid permit, or the permit has been revoked, and the condition of the unfinished construction presents an immediate serious and imminent threat to the life and safety of the occupants or the public.
VADR. The Virginia Amusement Device Regulations (13VAC5-31).
VCS. The Virginia Certification Standards (13VAC5-21).
Working day. A day other than Saturday, Sunday or a legal local, state or national holiday.
B. Change the following definitions in Section 202 of the IBC to read:
24-hour basis. The actual time that a person is an occupant within a facility for the purpose of receiving care. It shall not include a facility that is open for 24 hours and is capable of providing care to someone visiting the facility during any segment of the 24 hours.
Ambulatory health care facility. Buildings or portions thereof that are licensed by the Virginia Department of Health as outpatient surgical hospitals.
Automatic fire-extinguishing system. An approved system of devices and equipment that automatically detects a fire and discharges an approved fire-extinguishing agent onto or in the area of a fire and includes among other systems an automatic sprinkler system, unless otherwise expressly stated.
Building. A combination of materials, whether portable or fixed, having a roof to form a structure for the use or occupancy by persons, or property. The word "building" shall be construed as though followed by the words "or part or parts thereof" unless the context clearly requires a different meaning. "Building" shall not include roadway tunnels and bridges owned by the Virginia Department of Transportation, which shall be governed by construction and design standards approved by the Virginia Commonwealth Transportation Board.
For application of this code, each portion of a building that is completely separated from other portions by fire walls complying with Section 706 shall be considered as a separate building (see Section 503.1).
Custodial care. Assistance with day-to-day living tasks, such as assistance with cooking, taking medication, bathing, using toilet facilities, and other tasks of daily living. In other than in hospice facilities, custodial care includes occupants that have the ability to respond to emergency situations and evacuate at a slower rate or who have mental and psychiatric complications, or both.
Group home. A facility for social rehabilitation or substance abuse or mental health problems that contains a group housing arrangement that provides custodial care but does not provide medical care.
Owner. The owner or owners of the freehold of the premises or lesser estate therein, a mortgagee or vendee in possession, assignee of rents, receiver, executor, trustee or lessee in control of a building or structure.
Registered Design Professional (RDP). An architect or professional engineer, licensed to practice architecture or engineering, as defined under § 54.1-400 of the Code of Virginia.
Swimming pool. An aquatic vessel as defined in the International Swimming Pool and Spa Code (ISPSC).
Structure. An assembly of materials forming a construction for occupancy or use including stadiums, gospel and circus tents, reviewing stands, platforms, stagings, observation towers, radio towers, water tanks, storage tanks (underground and aboveground), trestles, piers, wharves, swimming pools, amusement devices, storage bins, and other structures of this general nature but excluding water wells. The word "structure" shall be construed as though followed by the words "or part or parts thereof" unless the context clearly requires a different meaning. "Structure" shall not include roadway tunnels and bridges owned by the Virginia Department of Transportation, which shall be governed by construction and design standards approved by the Virginia Commonwealth Transportation Board.
C. Delete the following definitions from Section 202 of the IBC:
Agricultural, building.
Existing structure (For Chapter 34).
Fly gallery.
Gridiron.
13VAC5-63-210. Chapter 3 Use and occupancy classification.
A. Change Section 303.6 of the IBC to read:
303.6 Assembly Group A-5. Assembly uses intended for participation in or viewing outdoor activities including, but not limited to:
Amusement park structures
Bleachers
Grandstands
Stadiums
Swimming pools
B. Change exception 13 of Section 307.1 of the IBC to read:
13. The storage of black powder, smokeless propellant and small arms primers in Groups M, R-3 and R-5 and special industrial explosive devices in Groups B, F, M and S, provided such storage conforms to the quantity limits and requirements prescribed in the International Fire Code IFC, as amended in Section 307.9.
[ C. Change the "Consumer fireworks" row and add a new "Permissible fireworks" row to Table 307.1(1) of the IBC to read:
Consumer fireworks | 1.4G | H-3 | 125e,l | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Permissible fireworks | 1.4G | H-3 | 125d,e,l | N/A | N/A | N/A | N/A | N/A | N/A | N/A ] |
B. [ C. D. ] Add Section 307.9 to the IBC to read:
307.9 Amendments. The following changes shall be made to the International Fire Code IFC for the use of Exception 13 in Section 307.1:
1. Change the following definition in Section 202 of the IFC to read:
Smokeless propellants. Solid propellants, commonly referred to as smokeless powders, or any propellants classified by DOTn as smokeless propellants in accordance with NA3178 (Smokeless Powder for Small Arms), used in small arms ammunition, firearms, cannons, rockets, propellant-actuated devices, and similar articles.
2. Change Section 314.1 of the IFC to read as follows:
314.1 General. Indoor displays constructed within any building or structure shall comply with Sections 314.2 through 314.5.
2. 3. Add new Section 314.5 to the IFC to read as follows:
314.5 Smokeless powder and small arms primers. Vendors shall not store, display or sell smokeless powder or small arms primers during trade shows inside exhibition halls except as follows:
1. The amount of smokeless powder each vender may store is limited to the storage arrangements and storage amounts established in Section 3306.5.2.1 5506.5.2.1.
2. Smokeless powder shall remain in the manufacturer's original sealed container and the container shall remain sealed while inside the building. The repackaging of smokeless powder shall not be performed inside the building. Damaged containers shall not be repackaged inside the building and shall be immediately removed from the building in such manner to avoid spilling any powder.
3. There shall be at least 50 feet separation between vendors and 20 feet from any exit.
4. Small arms primers shall be displayed and stored in the manufacturer's original packaging and in accordance with the requirements of Section 3306.5.2.3 5506.5.2.3.
3. 4. Change Exception 4 and add Exceptions 10 and 11 to Section 3301.1 5501.1 of the IFC as follows:
4. The possession, storage and use of not more than 15 pounds (6.75 kg) of commercially manufactured sporting black powder, 20 pounds (9 kg) of smokeless powder and any amount of small arms primers for hand loading of small arms ammunition for personal consumption.
10. The display of small arms primers in Group M when in the original manufacturer's packaging.
11. The possession, storage and use of not more than 50 pounds (23 kg) of commercially manufactured sporting black powder, 100 pounds (45 kg) of smokeless powder, and small arms primers for hand loading of small arms ammunition for personal consumption in Group R-3 or R-5, or 200 pounds (91 kg) of smokeless powder when stored in the manufacturer's original containers in detached Group U structures at least 10 feet (3048 mm) from inhabited buildings and are accessory to Group R-3 or R-5.
4. Change the definition of Smokeless Propellants in Section 3302.1 of the IFC as follows:
SMOKELESS PROPELLANTS. Solid propellants, commonly referred to as smokeless powders, or any propellants classified by DOTn as smokeless propellants in accordance with NA3178 (Smokeless Powder for Small Arms), used in small arms ammunition, firearms, cannons, rockets, propellant-actuated devices and similar articles.
5. Change Section 3306.4 5506.4 of the IFC to read as follows:
3306.4 5506.4 Storage in residences. Propellants for personal use in quantities not exceeding 50 pounds (23 kg) of black powder or 100 pounds (45 kg) of smokeless powder shall be stored in original containers in occupancies limited to Group R-3 and R-5 or 200 pounds (91 kg) of smokeless powder when stored in the manufacturer's original containers in detached Group U structures at least 10 feet (3048 mm) from inhabited buildings and are accessory to Group R-3 or R-5. In other than Group R-3 or R-5, smokeless powder in quantities exceeding 20 pounds (9 kg) but not exceeding 50 pounds (23 kg) shall be kept in a wooden box or cabinet having walls of at least one inch (25 mm) nominal thickness or equivalent.
6. Delete Sections 3306.4.1 5506.4.1 and 3306.4.2 5506.4.2 of the IFC.
7. Change Section 3306.5.1.1 5506.5.1.1 of the IFC to read as follows:
3306.5.1.1 5506.5.1.1 Smokeless propellant. No more than 100 pounds (45 kg) of smokeless propellants in containers of eight pounds (3.6 kg) or less capacity shall be displayed in Group M occupancies.
8. Delete Section 3306.5.1.3 5506.5.1.3 of the IFC.
9. Change Section 3306.5.2.1 5506.5.2.1 of the IFC as follows:
3306.5.2.1 5506.5.2.1 Smokeless propellant. Commercial stocks of smokeless propellants shall be stored as follows:
1. Quantities exceeding 20 pounds (9 kg), but not exceeding 100 pounds (45 kg) shall be stored in portable wooden boxes having walls of at least one inch (25 mm) nominal thickness or equivalent.
2. Quantities exceeding 100 pounds (45 kg), but not exceeding 800 pounds (363 kg), shall be stored in storage cabinets having walls at least one inch (25 mm) nominal thickness or equivalent. Not more than 400 pounds (182 kg) shall be stored in any one cabinet, and cabinets shall be separated by a distance of at least 25 feet (7620 mm) or by a fire partition having a fire-resistance rating of at least one hour.
3. Storage of quantities exceeding 800 pounds (363 kg), but not exceeding 5,000 pounds (2270 kg) in a building shall comply with all of the following:
3.1. The storage is inaccessible to unauthorized personnel.
3.2. Smokeless propellant shall be stored in nonportable storage cabinets having wood walls at least one inch (25 mm) nominal thickness or equivalent and having shelves with no more than 3 feet (914 mm) of vertical separation between shelves.
3.3. No more than 400 pounds (182 kg) is stored in any one cabinet.
3.4. Cabinets shall be located against walls with at least 40 feet (12 192 mm) between cabinets. The minimum required separation between cabinets may be reduced to 20 feet (6096 mm) provided that barricades twice the height of the cabinets are attached to the wall, midway between each cabinet. The barricades must extend a minimum of 10 feet (3048 mm) outward, be firmly attached to the wall, and be constructed of steel not less than 0.25 inch thick (6.4 mm), 2-inch (51 mm) nominal thickness wood, brick, or concrete block.
3.5. Smokeless propellant shall be separated from materials classified as combustible liquids, flammable liquids, flammable solids, or oxidizing materials by a distance of 25 feet (7620 mm) or by a fire partition having a fire-resistance rating of 1 hour.
3.6. The building shall be equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1.
4. Smokeless propellants not stored according to Item 1, 2, or 3 above shall be stored in a Type 2 or 4 magazine in accordance with Section 3304 and NFPA 495.
C. Change [ D. E. ] Add the following to the list of terms in Section 308.2 of the IBC to read:
Hospice facility
[ E. F. ] Change Section 308.3 of the IBC to read:
308.2 308.3 Institutional Group I-1. This occupancy shall include buildings, structures or parts portions thereof housing for more than 16 persons, excluding staff, who reside on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment that provides personal and receive custodial care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. Buildings of Group I-1, other than assisted living facilities licensed by the Virginia Department of Social Services, shall be classified as the occupancy condition indicated in Section 308.3.1. Assisted living facilities licensed by the Virginia Department of Social Services shall be classified as one of the occupancy conditions indicated in Section 308.3.1 or 308.3.2. This group shall include, but not be limited to, the following:
Alcohol and drug centers
Assisted living facilities
Congregate care facilities
Group homes
Halfway houses
Residential board and care facilities
Social rehabilitation facilities
[ Exception: In Group I-1 occupancies classified as the occupancy condition indicated in Section 308.3.1, not more than five of the residents may require physical assistance from staff to respond to an emergency situation when all residents that may require the physical assistance reside on a single level of exit discharge. ]
A facility such as the above with five or fewer persons shall be classified as a Group R-3 or shall comply with the International Residential Code in accordance with Section 101.2. A facility such as above, housing at least six and not more than 16 persons, shall be classified as Group R-4.
[ F. G. ] Change Sections 308.3.1 and 308.3.2 of the IBC to read:
308.3.1 Condition 1. This occupancy condition shall include buildings in which all persons receiving custodial care who, without any assistance, are capable of responding to an emergency situation to complete building evacuation. [ Not more than five of the residents may require physical assistance from staff to respond to an emergency situation when all residents who may require the physical assistance reside on a single level of exit discharge. ]
308.3.2 Condition 2. This occupancy condition shall include buildings in which there are persons receiving custodial care who require assistance by not more than one staff member while responding to an emergency situation to complete building evacuation. [ Five of the residents may require physical assistance from more than one staff member to respond to an emergency.
G. H. ] Add Sections 308.3.3 and 308.3.4 to the IBC to read:
308.3.3 Six to 16 persons receiving custodial care. A facility housing not fewer than six and not more than 16 persons receiving custodial care shall be classified as Group R-4.
308.3.4 Five or fewer persons receiving custodial care. A facility with five or fewer persons receiving custodial care shall be classified as Group R-3 or shall comply with the IRC provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or with Section P2904 of the IRC.
D. [ H. I. ] Change Section 308.3 308.4 of the IBC to read:
308.3 308.4 Group I-2. This occupancy shall include buildings and structures used for medical, surgical, psychiatric, nursing or custodial care on a 24-hour basis for more than five persons who are not capable incapable of self-preservation. This group shall include, but not be limited to, the following:
Child care facilities
Convalescent facilities
Detoxification facilities
Foster care facilities
Hospice facilities
Hospitals
Mental hospitals
Nursing homes
Psychiatric hospitals
Exception: Hospice facilities occupied by 16 or less occupants, excluding staff, are permitted to be classified as Group R-4.
E. Add the following definition to Section 308.3.1 of the IBC:
Hospice facility. An institution, place, or building owned or operated by a hospice provider and licensed by the Virginia Department of Health as a hospice facility to provide room, board, and palliative and supportive medical and other health services to terminally ill patients and their families, including respite and symptom management, on a 24-hour basis to individuals requiring such care pursuant to the orders of a physician.
F. Change [ I. J. ] Add an exception to Section 308.5.2 308.6 of the IBC to read:
308.5.2 Child care facility. A facility other than family day homes under Section 310.4 that provides supervision and personal care on less than a 24-hour basis for more than five children 2-1/2 years of age or less shall be classified as Group I-4.
Exception: A child day care facility that provides care for more than five but no more than 100 children 2-1/2 years or less of age, where the rooms in which the children are cared for are located on a level of exit discharge serving such rooms and each of these child care rooms has an exit door directly to the exterior, shall be classified as Group E Family day homes under Section 310.9.
G. [ J. K. ] Change occupancy classifications "R-1" and "R-4" and add new occupancy classification "R-5" to Section 310 310.3 of the IBC to read:
310.3 Residential Group R-1. Residential occupancies containing sleeping units where the occupants are primarily transient in nature, including:
Boarding houses (transient) with more than 10 occupants
Congregate living facilities (transient) with more than 10 occupants
Hotels (transient)
Motels (transient)
Congregate living facilities (transient) with 10 or fewer occupants are permitted to comply with the construction requirements for Group R-3.
Exceptions:
1. Nonproprietor occupied bed and breakfast and other transient boarding facilities not more than three stories above grade plane in height with a maximum of 10 occupants total are permitted to be classified as either Group R-3 or Group R-5 provided that smoke alarms are installed in compliance with Section 907.2.10.1.2 907.2.11.2 for Group R-3 or Section 313.1 R314 of the International Residential Code IRC for Group R-5.
2. Proprietor occupied bed and breakfast and other transient boarding facilities not more than three stories above grade plane in height, that are also occupied as the residence of the proprietor, with a maximum of five guest room sleeping units provided for the transient occupants are permitted to be classified as either Group R-3 or R-5 provided that smoke alarms are installed in compliance with Section 907.2.10.1.2 907.2.11.2 for Group R-3 or Section 313.1 R314 of the International Residential Code IRC for Group R-5.
[ K. L. ] Change Section 310.6 of the IBC to read:
310.6 Residential Group R-4 Residential occupancies. This occupancy shall include buildings arranged for occupancy as residential care/assisted living facilities including, structures or portions thereof for more than five but not more than 16 occupants persons, excluding staff and buildings arranged for occupancy as, who reside on a 24-hour basis in a supervised environment and receive custodial care. Buildings of Group R-4, other than assisted living facilities licensed by the Virginia Department of Social Services, shall be classified as the occupancy condition indicated in Section 310.6.1. Assisted living facilities licensed by the Virginia Department of Social Services shall be classified as one of the occupancy conditions indicated in [ Sections Section ] 310.6.1 or 310.6.2. This group shall include, but not be limited to the following:
Alcohol and drug centers
Assisted living facilities
Congregate care facilities
Group homes
Halfway houses
Residential board and care facilities
Social rehabilitation facilities
This occupancy shall also include hospice facilities with not more than 16 occupants, excluding staff.
Group R-4 occupancies shall meet the requirements for construction as defined for Group R-3, except as otherwise provided for in this code, or shall comply with the IRC provided the building is protected by an automatic sprinkler system installed in accordance with Section 903.2.7.
Exceptions:
1. Group homes licensed by the Virginia Department of Behavioral Health and Developmental Services that house no more than eight persons with one or more resident counselors shall be classified as Group R-2, R-3, R-4 or R-5. Not more than five of the persons may require physical assistance from staff to respond to an emergency situation.
2. In Group R-4 occupancies classified as the occupancy condition indicated in Section 310.6.1, other than in hospice facilities, not more than five of the residents may require physical assistance from staff to respond to an emergency situation when all residents who may require the physical assistance from staff reside on a single level of exit discharge and other than using a ramp, a change of elevation using steps or stairs is not within the path of egress to an exit door.
3. Assisted living facilities licensed by the Virginia Department of Social Services that house no more than eight persons, with one or more resident counselors, and all of the residents are capable of responding to an emergency situation without physical assistance from staff, may be classified as Group R-2, R-3 or R-5.
4. Assisted living facilities licensed by the Virginia Department of Social Services that house no more than eight persons, with one or more resident counselors, may be classified as Group R-5 when in compliance with all of the following:
4.1. The building is protected by an automatic sprinkler system installed in accordance with Section 903.3 or Section P2904 of the IRC.
4.2. Not more than five of the residents may require physical assistance from staff to respond to an emergency situation.
4.3. All residents who may require physical assistance from staff to respond to an emergency situation reside on a single level of exit discharge and other than using a ramp, a change in elevation using steps or stairs is not within the path of egress to an exit door.
5. Hospice facilities with five or fewer occupants are permitted to comply with the IRC provided the building is protected by an automatic sprinkler system in accordance with IRC Section P2904 or IBC Section 903.3.
[ L. M. ] Add Sections 310.6.1 and 310.6.2 to the IBC to read:
310.6.1 Condition 1. This occupancy condition shall include buildings in which all persons receiving custodial care who, without any assistance, are capable of responding to an emergency situation to complete building evacuation and hospice facilities.
310.6.2 Condition 2. This occupancy condition shall include buildings in which there are persons receiving custodial care who require assistance by not more than one staff member while responding to an emergency situation to complete building evacuation.
[ M. N. ] Add Section 310.7 to the IBC to read:
310.7 Residential Group R-5. Residential occupancies in detached one- single-family and two-family dwellings, townhouses and accessory structures within the scope of the International Residential Code, also referred to as the "IRC."
H. Change the definition of "Residential care/assisted living facilities" in Section 310.2 of the IBC to read:
Residential care/assisted living facilities. Any congregate residential setting that provides or coordinates personal and health care services, 24-hour supervision and assistance for the maintenance or care of four or more adults who are aged, infirm or disabled and who are cared for in a primarily residential setting, and provides for the protection, general supervision and oversight of the physical and mental well-being of aged, infirmed or disabled individuals. Residents are capable of self-evacuation.
I. [ N. O. ] Add Section 310.3 310.8 to the IBC to read:
310.3 310.8 Group R-5. The construction of Group R-5 structures shall comply with the IRC. The amendments to the IRC set out in Section 310.6 310.11 shall be made to the IRC for its use as part of this code. In addition, all references to Section 101.2 in the IBC relating to the construction of such structures subject to the IRC in the IBC shall be considered to be references to this section.
J. [ O. P. ] Add Section 310.3.1 310.8.1 to the IBC to read:
310.3.1 310.8.1 Additional requirements. Methods of construction, materials, systems, equipment or components for Group R-5 structures not addressed by prescriptive or performance provisions of the IRC shall comply with applicable IBC requirements.
K. [ P. Q. ] Add Section 310.4 310.9 to the IBC to read:
310.4 310.9 Family day homes. Family day homes where program oversight is provided by the Virginia Department of Social Services shall be classified as Group R-2, R-3 or R-5.
Note: Family day homes may generally care for up to 12 children. See the DHCD Related Laws Package for additional information.
L. [ Q. R. ] Add Section 310.5 310.10 to the IBC to read:
310.5 310.10 Radon-resistant construction in Group Groups R-3 and R-4 structures. Group Groups R-3 and R-4 structures shall be subject to the radon-resistant construction requirements in Appendix F of the IRC in localities enforcing such requirements pursuant to Section R325 R324 of the IRC.
M. [ R. S. ] Add Section 310.6 310.11 to the IBC to read:
310.6 310.11 Amendments to the IRC. The following changes shall be made to the IRC for its use as part of this code:
1. Add the following definitions to read:
Nonpotable fixtures and outlets. Fixtures and outlets that are not dependent on potable water for the safe operation to perform their intended use. Such fixtures and outlets may include, but are not limited to water closets, urinals, irrigation, mechanical equipment, and hose connections to perform operations, such as vehicle washing and lawn maintenance.
Nonpotable water systems. Water systems for the collection, treatment, storage, distribution, and use or reuse of nonpotable water. Nonpotable systems include reclaimed water, rainwater, and gray water systems.
Rainwater. Natural precipitation, including snow melt, from roof surfaces only.
Stormwater. Precipitation that is discharged across the land surface or through conveyances to one or more waterways and that may include stormwater runoff, snow melt runoff, and surface runoff and drainage.
2. Change the following [ definition definitions ] to read:
[ Attic, habitable. A finished or unfinished area, not considered a story, complying with all of the following requirements:
1. The occupiable floor area is at least 70 square feet (17 m2), in accordance with Section R304,
2. The occupiable floor area has a ceiling height in accordance with Section R305, and
3. The occupiable space is enclosed by the roof assembly above, knee walls (if applicable) on the sides and the floor-ceiling assembly below.
Habitable attics greater than two-thirds of the area of the story below or over 400 square feet (37.16 m2) shall not be permitted in dwellings or townhouses that are three stories above grade plane in height. ]
Gray water. Water discharged from lavatories, bathtubs, showers, clothes washers, and laundry trays.
3. Change Section R301.2.1 to read:
R301.2.1 Wind limitations design criteria. Buildings and portions thereof shall be limited by constructed in accordance with the wind provisions of this code using the basic wind speed, as defined in Table R301.2(1), and construction methods in accordance with this code. Basic wind speeds shall be determined from Figure R301.2(4). Where different construction methods and structural materials are used for various portions of a building, the applicable requirements of this section for each portion shall apply. Where loads for wall coverings, curtain walls, roof coverings, exterior windows, skylights, garage doors and exterior doors are not otherwise specified, the loads listed in Table R301.2(2) adjusted for height and exposure using Table R301.2(3) shall be used to determine design load performance requirements for wall coverings, curtain walls, roof coverings, exterior windows, skylights, garage doors and exterior doors. Asphalt shingles shall be designed for wind speeds in accordance with Section R905.2.6 as determined from Figure R301.2(4)A. The structural provisions of this code for wind loads are not permitted where wind design is required as specified in Section R301.2.1.1. Where different construction methods and structural materials are used for various portions of a building, the applicable requirements of this section for each portion shall apply. Where not otherwise specified, the wind loads listed in Table R301.2(2) adjusted for height and exposure using Table R301.2(3) shall be used to determine design load performance requirements for wall coverings, curtain walls, roof coverings, exterior windows, skylights, garage doors, and exterior doors. Asphalt shingles shall be designed for wind speeds in accordance with Section R905.2.4. A continuous load path shall be provided to transmit the applicable uplift forces in Section R802.11.1 from the roof assembly to the foundation. Wind speeds for localities in special wind regions, near mountainous terrain, and near gorges shall be based on elevation. Areas at 4,000 feet in elevation or higher shall use 110 V mph (48.4 m/s) and areas under 4,000 feet in elevation shall use 90 V mph (39.6 m/s). Gorge areas shall be based on the highest recorded speed per locality or in accordance with local jurisdiction requirements determined in accordance with Section 6.5.4 26.5.1 of ASCE 7.
2. Change Section R301.2.1.1 to read:
R301.2.1.1 Design criteria. Construction in regions where the basic wind speeds from Figure R301.2(4) equal or exceed 110 miles per hour (49 m/s) shall be designed in accordance with one of the following methods. The elements of design not addressed by those documents in items 1 through 4 shall be in accordance with this code.
1. American Forest and Paper Association (AF&PA) Wood Frame Construction Manual for One- and Two-Family Dwellings (WFCM); or
2. International Code Council (ICC) Standard for Residential Construction in High Wind Regions (ICC-600); or
3. Minimum Design Loads for Buildings and Other Structures (ASCE-7); or
4. American Iron and Steel Institute (AISI), Standard for Cold-Formed Steel Framing-Prescriptive Method for One- and Two-Family Dwellings (AISI S230).
5. Concrete construction shall be designed in accordance with the provisions of this code.
6. Structural insulated panel (SIP) walls shall be designed in accordance with the provisions of this code.
3. Change Section R301.2.2.1.1 to read:
R301.2.2.1.1 Alternate determination of seismic design category. The Seismic Design Categories and corresponding Short Period Design Spectral Response Accelerations, SDS shown in Figure R301.2(2) are based on soil Site Class D, as defined in Section 1613.5.2 of the International Building Code. If soil conditions are other than Site Class D, the Short Period Design Spectral Response Accelerations, SDS, for a site can be determined according to Section 1613.5 of the International Building Code. The value of SDS determined according to Section 1613.5 of the International Building Code is permitted to be used to set the seismic design category according to Table R301.2.2.1.1, and to interpolate between values in Tables R602.10.3(3), R603.7 and other seismic design requirements of this code.
4. Delete Section R301.2.2.3 and all subsections.
5. Delete Section R301.2.2.4.
6. Change the exception to Item 1 of Section R301.3 to read:
Exception: For wood framed wall buildings with bracing in accordance with Section R602.10, the wall stud clear height used to determine the maximum permitted story height may be increased to 12 feet (3658 mm) without requiring an engineered design for the building wind and seismic force resisting systems.
7. 4. Add Exception 6 to Section R302.1 to read:
6. Decks and open porches.
8. Change the last column and add footnote "a" to Table R302.1 as shown:
Minimum Fire Separation Distance |
<5 feeta |
≥5 feeta |
≥2 feet to 5 feeta |
5 feeta |
<3 feet |
3 feet |
5 feeta |
<5 feeta |
5 feeta |
aThe minimum fire separation distance shall be reduced to three feet in developments which are fully sprinklered as provided for in Sections R313.1 or R313.2.
9. 5. Change the exception in Section R302.2 to require a common two-hour fire-resistance-rated wall instead of a one-hour fire-resistance-rated wall, unless the townhouse development is fully sprinklered as provided for in Section R313.1, in which case a common one-hour fire-resistive-rated wall shall be permitted between townhouses.
10. 6. Add the following sentence to the end of Section R302.3 to read:
Dwelling unit separation wall assemblies that are constructed on a lot line shall be constructed as required in Section R302.2 for townhouses.
7. Change Section R302.5.1 to read:
R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1–3/8 inches (35 mm) thickness, solid or honeycomb-core steel doors not less than 1–3/8 inches (35 mm) thick, or 20-minute fire-rated doors.
11. 8. Add an exception to Section R303.8 R303.9 to read:
Exception: Seasonal structures not used as a primary residence for more than 90 days per year, unless rented, leased or let on terms expressed or implied to furnish heat, shall not be required to comply with this section.
12. 9. Add Section R303.8.1 R303.9.1 to read:
R303.8.1 R303.9.1 Nonowner occupied required heating. Every dwelling unit or portion thereof which is to be rented, leased or let on terms either expressed or implied to furnish heat to the occupants thereof shall be provided with facilities in accordance with Section R303.8 R303.9 during the period from October 15 to May 1.
13. 10. Add Section R303.9 R303.10 to read:
R303.9 R303.10 Insect screens. Every door, window and other outside opening required for ventilation purposes shall be supplied with approved tightly fitted screens of not less than 16 mesh per inch (16 mesh per 25 mm) and every screen door used for insect control shall have a self-closing device.
14. 11. Add Section R306.5 to read:
R306.5 Water supply sources and sewage disposal systems. The water and drainage system of any building or premises where plumbing fixtures are installed shall be connected to a public or private water supply and a public or private sewer system. As provided for in Section [ 103.11 103.10 ] of Part I of the Virginia Uniform Statewide Building Code (13VAC5-63), for functional design, water supply sources and sewage disposal systems are regulated and approved by the Virginia Department of Health and the Virginia Department of Environmental Quality.
Note: See also the Memorandums of Agreement in the "Related Laws Package," which is available from the Virginia Department of Housing and Community Development.
15. 12. Change Section R310.1 to read:
R310.1 Emergency escape and rescue required. Basements, habitable attics, and each every sleeping room designated on the construction documents shall have at least one openable operable emergency escape and rescue opening. Such opening shall be directly to the exterior of the building or to a deck, screen porch or egress court, all of which shall provide access to a public street, public alley or yard. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Where emergency escape and rescue openings are provided, they shall have a sill height of not more than 44 inches (1118 mm) above measured from the finished floor to the bottom of the clear opening. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside, except that tilt-out or removable sash designed windows shall be permitted to be used. Emergency escape and rescue openings with a finished height below the adjacent ground elevation shall be provided with a window well in accordance with Section R310.2. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way.
Exceptions:
1. Dwelling units equipped throughout with an approved automatic sprinkler system installed in accordance with NFPA 13, 13R, or 13D or Section P2904.
2. Basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet (18.58 m2).
16. 13. Change Section R310.1.1 to read:
R310.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2), including the tilting or removal of the sash as the normal operation to comply with sections Sections R310.1.2 and R310.1.3.
Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet (0.465 m2).
[ 14. Add Section R311.2.1 to read:
R311.2.1 Interior passage. Where a dwelling unit has both a kitchen and a living or entertainment area on the same level as the egress door required by Section R311.2, an interior passage route shall be provided from such egress door to the kitchen and the living or entertainment area and to at least one bedroom and at least one bathroom containing a water closet, lavatory and bathtub or shower, where such rooms are provided on that same level. Any doors or cased openings along such interior passage route providing access to the areas identified above shall comply with the following.
1. Cased openings shall provide a minimum 34-inch clear width.
2. Doors shall be, at a minimum, nominal 34-inch doors.
Exceptions:
1. Where a door or cased opening, and its associated molding or trim, is at the end and facing the length of a hallway and the width of the hallway is not wide enough to accommodate such doors or cased openings.
2. Closet doors or cased openings.
3. Pantry door or cased openings.
4. Bathrooms accessed directly from a bedroom that is not required to comply with this section.
15. Change the exception in Section R311.3.1 to read:
Exception: The landing or floor on the exterior side shall not be more than 8-1/4 inches (210 mm) below the top of the threshold provided the door does not swing over the landing or floor. ]
17. [ 14. 16. ] Change Section R311.7.4.1 R311.7.5.1 to read:
R311.7.4.1 Riser height R311.7.5.1 Risers. The maximum riser height shall be 8-1/4 inches (210 mm). The riser shall be measured vertically between the leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch-diameter (102 mm) sphere.
Exception: The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less.
18. [ 15. 17. ] Change Section R311.7.4.2 R311.7.5.2 to read:
R311.7.4.2 Tread depth R311.7.5.2 Treads. The minimum tread depth shall be 9 inches (229 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Consistently shaped winders at the walkline shall be allowed within the same flight of stairs as rectangular treads and do not have to be within 3/8 inch (9.5 mm) of the rectangular tread depth. Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured between the vertical planes of the foremost projection of adjacent treads at the intersection with the walkline. Winder treads shall have a minimum tread depth of 6 inches (152 mm) at any point within the clear width of the stair. Within any flight of stairs, the largest winder tread depth at the walkline shall not exceed the smallest winder tread by more than 3/8 inch (9.5 mm).
19. [ 16. 18. ] Change Section R311.7.6 R311.7.7 to read:
R311.7.6 R311.7.7 Stairway walking surface. The walking surface of treads and landings of stairways shall be level or sloped no steeper than one unit vertical in 48 [ inches units ] horizontal (two-percent slope) (2.0% slope).
[ 17. 19. ] Change Section R312.2.1 to read:
R312.2.1 Window sills. In dwelling units, where the opening of an operable window is located more than 72 inches (1829 mm) above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 18 inches (457 mm) above the finished floor of the room in which the window is located. Operable sections of windows shall not permit openings that allow passage of a 4-inch-diameter (102 mm) sphere where such openings are located within 18 inches (457 mm) of the finished floor.
Exceptions:
1. Windows whose openings will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening when the opening is in its largest opened position.
2. Openings that are provided with window fall prevention devices that comply with ASTM F 2090.
3.Windows that are provided with window opening control devices that comply with Section R312.2.2.
[ 20. 18. ] Replace Section R313 with the following:
Section R313.
Automatic Fire Sprinkler Systems.
R313.1 Townhouse automatic fire sprinkler systems. Notwithstanding the requirements of Section 103.8, where installed, an automatic residential fire sprinkler system for townhouses shall be designed and installed in accordance with NFPA 13D or Section P2904.
Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed.
R313.2 One-family and two-family dwellings automatic fire sprinkler systems. Notwithstanding the requirements of Section 103.8, where installed, an automatic residential fire sprinkler system shall be designed and installed in accordance with NFPA 13D or Section P2904.
Exception: An automatic residential fire sprinkler system shall not be required for additions or alterations to existing buildings that are not already provided with an automatic residential fire sprinkler system.
[ 21. 19. ] Change Section R314.2 to read:
R314.2 Smoke detection systems. Household fire alarm systems installed in accordance with NFPA 72 that include smoke alarms, or a combination of smoke detector and audible notification device installed as required by this section for smoke alarms, shall be permitted. The household fire alarm system shall provide the same level of smoke detection and alarm as required by this section for smoke alarms. Where a household fire warning system is installed using a combination of smoke detector and audible notification device(s), the system shall become a permanent fixture of the dwelling unit.
Exception: Where smoke alarms are provided meeting the requirements of Section R314.4.
[ 22. 20. ] Delete Section R314.3.1.
[ 23. 21. ] Delete Section R315.2 R315.3.
[ 24. 22. ] Change Section R315.2 R315.4 to read:
R315.3 R315.4 Alarm requirements. Single station carbon monoxide alarms shall be hard wired, plug-in or battery type; listed as complying with UL 2034; and installed in accordance with this code and the manufacturer's installation instructions.
[ 25. Add Exception 3 to Section R317.1.4 to read:
3. Deck posts supported by concrete piers or metal pedestals projecting a minimum of one inch (25.4 mm) above a concrete floor or six inches (152 mm) above exposed earth.
23. 26. ] Add Section R320.2 to read:
R320.2 Universal design features for accessibility in dwellings. Dwellings constructed under the IRC not subject to Section R320.1 may comply with Section 1109.16 of the USBC and be approved by the local building department as dwellings containing universal design features for accessibility.
25. [ 24. 27. ] Add Section R324 Radon-Resistant Construction.
26. [ 25. 28. ] Add Section R324.1 to read:
R324.1 Local enforcement of radon requirements. Following official action under Article 7 (§ 15.2-2280 et seq.) of Chapter 22 of Title 15.2 of the Code of Virginia by a locality in areas of high radon potential, as indicated by Zone 1 on the U.S. EPA Map of Radon Zones (IRC Figure AF101), such locality shall enforce the provisions contained in Appendix F.
Exception: Buildings or portions thereof with crawl space foundations which are ventilated to the exterior, shall not be required to provide radon-resistant construction.
27. [ 26. 29. ] Add Section R325 Swimming Pools, Spas and Hot Tubs.
28. [ 27. 30. ] Add Section R325.1 to read:
R325.1 Use of Appendix G for swimming Swimming pools, spas and hot tubs. In addition to other applicable provisions of this code, swimming pools, spas and hot tubs as defined in the USBC, shall comply with the applicable provisions in Appendix G of the ISPSC.
29. [ 28. 31. ] Add Section R326 Patio Covers.
30. [ 29. 32. ] Add Section R326.1 to read:
R326.1 Use of Appendix H for patio covers. Patio covers shall comply with the provisions in Appendix H.
31. [ 30. 33. ] Add Section R327 Sound Transmission.
32. [ 31. 34. ] Add Section R327.1 to read:
R327.1 Sound transmission between dwelling units. Construction assemblies separating dwelling units shall provide airborne sound insulation as required in Appendix K.
33. [ 32. 35. ] Add Section R327.2 to read:
R327.2 Airport noise attenuation. This section applies to the construction of the exterior envelope of detached one-family and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories high with separate means [ or of ] egress within airport noise zones when enforced by a locality pursuant to § 15.2-2295 of the Code of Virginia. The exterior envelope of such structures shall comply with Section 1207.4 of the state amendments to the IBC.
34. Add Section R328 Gray Water and Rain Water Recycling Systems.
35. Add Section R328.1 to read:
R328.1 Use of Appendix O for gray water and rain water recycling systems. In addition to other applicable provisions of this code, gray water recycling systems and rain water recycling systems shall comply with the provisions in Appendix O. In the use of Appendix O for rain water recycling systems, the term "rain water" shall be substituted for the term "gray water." Gray water recycling systems and rain water recycling systems shall be separate systems and shall not be interconnected.
[ 36. 33. ] Add Section [ R329 R328 ] Fire Extinguishers.
[ 37. 34. ] Add Section [ R329.1 R328.1 ] to read:
[ R329.1 R328.1 ] Kitchen areas. Other than where the dwelling is equipped with an approved sprinkler system in accordance with Section R313, a fire extinguisher having a rating of 2-A:10-B:C or an approved equivalent type of fire extinguisher shall be installed in the kitchen area.
[ 38. 35. ] Change Section R401.3 to read:
R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard to the dwelling unit. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of six inches (152 mm) within the first 10 feet (3048 mm).
Exception: Where lot lines, walls, slopes or other physical barriers prohibit six inches (152 mm) of fall within 10 feet (3048 mm), drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet (3048 mm) of the building foundation shall be sloped a minimum of 2.0% away from the building.
[ 39. 36. ] Change Section R403.1 to read:
R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings, wood foundations, or other approved structural systems which that shall be of sufficient design to accommodate all loads according to Section R301 and to transmit the resulting loads to the soil within the limitations as determined from the character of the soil. Footings shall be supported on undisturbed natural soils or engineered fill.
[ Exception Exceptions:
1. ] One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, not exceeding 256 square feet (23.7824 m2) of building area, provided all of the following conditions are met:
[ 1. 1.1. ] The building eave height is 10 feet or less.
[ 2. 1.2. ] The maximum height from the finished floor level to grade does not exceed 18 inches.
[ 3. 1.3. ] The supporting structural elements in direct contact with the ground shall be placed level on firm soil and when such elements are wood they shall be approved pressure preservative treated suitable for ground contact use.
[ 4. 1.4. ] The structure is anchored to withstand wind loads as required by this code.
[ 5. 1.5. ] The structure shall be of light-frame construction whose vertical and horizontal structural elements are primarily formed by a system of repetitive wood or light gauge steel framing members, with walls and roof of light weight material, not slate, tile, brick or masonry.
[ 2. Footings are not required for ramps serving dwelling units in Group R-3 and R-5 occupancies where the height of the entrance is no more than 30 inches (762 mm) above grade. ]
40. Change Exceptions 2 and 3 in Section R403.1.6 to read:
2. Walls 24 inches (610 mm) total length or shorter connecting offset braced wall panels shall be anchored to the foundation with a minimum of one anchor bolt located in the center third of the plate section.
3. Connection of walls 12 inches (305 mm) total length or shorter connecting offset braced wall panels to the foundation without anchor bolts shall be permitted.
41. Delete Item 5 of Section R403.1.6.1.
42. [ 37. 40. ] Add Section R408.3.1 to read:
R408.3.1 Termite inspection. Where an unvented crawl space is installed and meets the criteria in Section R408, the vertical face of the sill plate shall be clear and unobstructed and an inspection gap shall be provided below the sill plate along the top of any interior foundation wall covering. The gap shall be a minimum of one inch (25.4 mm) and a maximum of two inches (50.8 mm) in width and shall extend throughout all parts of any foundation that is enclosed. Joints between the sill plate and the top of any interior wall covering may be sealed.
Exceptions:
1. In areas not subject to damage by termites as indicated by Table R301.2(1).
2. Where other approved means are provided to inspect for potential damage.
Where pier and curtain foundations are installed as depicted in Figure R404.1.5(1), the inside face of the rim joist and sill plate shall be clear and unobstructed except for construction joints which may be sealed.
Exception: Fiberglass or similar insulation may be installed if easily removable.
43. Change Section R502.2.1 to read:
R502.2.1 Framing at braced wall panels. A load path for lateral forces shall be provided between floor framing and braced wall panels located above or below a floor, as specified in Sections R602.3.5 and R602.10.8.
[ 41. Change the indicated rows of Table R502.3.1(1) to
read:
Joist Spacing (inches) | Species and Grade | Dead Load = 10 psf | Dead Load = 20 psf |
2x6 | 2x8 | 2x10 | 2x12 | 2x6 | 2x8 | 2x10 | 2x12 |
Maximum floor joist spans |
(ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) |
12 | Southern Pine SS | 12-3 | 16-2 | 20–8 | 25-1 | 12-3 | 16-2 | 20–8 | 25-1 |
Southern Pine #1 | 11-10 | 15-7 | 19-10 | 24-2 | 11-10 | 15-7 | 18-7 | 22-0 |
Southern Pine #2 | 11-3 | 14-11 | 18-1 | 21-4 | 10-9 | 13-8 | 16-2 | 19-1 |
Southern Pine #3 | 9-2 | 11–6 | 14-0 | 16-6 | 8-2 | 10-3 | 12-6 | 14-9 |
16 | Southern Pine SS | 11-2 | 14-8 | 18-9 | 22-10 | 11–2 | 14-8 | 18-9 | 22-10 |
Southern Pine #1 | 10-9 | 14-2 | 18-0 | 21–4 | 10-9 | 13-9 | 16-1 | 19-1 |
Southern Pine #2 | 10-3 | 13-3 | 15-8 | 18-6 | 9-4 | 11-10 | 14-0 | 16-6 |
Southern Pine #3 | 7-11 | 10-0 | 12-1 | 14-4 | 7-1 | 8-11 | 10-10 | 12-10 |
19.2 | Southern Pine SS | 10-6 | 13-10 | 17-8 | 21–6 | 10-6 | 13-10 | 17-8 | 21–6 |
Southern Pine #1 | 10-1 | 13-4 | 16-5 | 19-6 | 9-11 | 12-7 | 14-8 | 17-5 |
Southern Pine #2 | 9-6 | 12-1 | 14-4 | 16-10 | 8-6 | 10-10 | 12-10 | 15-1 |
Southern Pine #3 | 7-3 | 9-1 | 11-0 | 13-1 | 6-5 | 8-2 | 9-10 | 11-8 |
24 | Southern Pine SS | 9-9 | 12-10 | 16-5 | 19-11 | 9-9 | 12-10 | 16-5 | 19-8 |
Southern Pine #1 | 9-4 | 12-4 | 14-8 | 17-5 | 8-10 | 11–3 | 13-1 | 15-7 |
Southern Pine #2 | 8-6 | 10-10 | 12-10 | 15-1 | 7-7 | 9-8 | 11–5 | 13-6 |
Southern Pine #3 | 6-5 | 8-2 | 9-10 | 11-8 | 5-9 | 7-3 | 8-10 | 10-5 |
42. Change the indicated rows of Table R502.3.1(2) to read:
Joist Spacing (inches) | Species and Grade | Dead Load = 10 psf | Dead Load = 20 psf |
2x6 | 2x8 | 2x10 | 2x12 | 2x6 | 2x8 | 2x10 | 2x12 |
Maximum floor joist spans |
(ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) | (ft.-in.) |
12 | Southern Pine SS | 11–2 | 14-8 | 18-9 | 22-10 | 11–2 | 14-8 | 18-9 | 22-10 |
Southern Pine #1 | 10-9 | 14-2 | 18-0 | 21–11 | 10-9 | 14-2 | 16-11 | 20–1 |
Southern Pine #2 | 10-3 | 13-6 | 16-2 | 19-1 | 9-10 | 12-6 | 14-9 | 17-5 |
Southern Pine #3 | 8-2 | 10-3 | 12-6 | 14-9 | 7-5 | 9-5 | 11–5 | 13-6 |
16 | Southern Pine SS | 10-2 | 13-4 | 17-0 | 20–9 | 10-2 | 13-4 | 17-0 | 20–9 |
Southern Pine #1 | 9-9 | 12-10 | 16-1 | 19-1 | 9-9 | 12-7 | 14-8 | 17-5 |
Southern Pine #2 | 9-4 | 11–10 | 14-0 | 16-6 | 8-6 | 10-10 | 12-10 | 15-1 |
Southern Pine #3 | 7-1 | 8-11 | 10-10 | 12-10 | 6-5 | 8-2 | 9-10 | 11–8 |
19.2 | Southern Pine SS | 9-6 | 12-7 | 16-0 | 19-6 | 9-6 | 12-7 | 16-0 | 19-6 |
Southern Pine #1 | 9-2 | 12-1 | 14-8 | 17-5 | 9-0 | 11–5 | 13-5 | 15-11 |
Southern Pine #2 | 8-6 | 10-10 | 12-10 | 15-1 | 7-9 | 9-10 | 11-8 | 13-9 |
Southern Pine #3 | 6-5 | 8-2 | 9-10 | 11–8 | 5-11 | 7-5 | 9-0 | 10-8 |
24 | Southern Pine SS | 8-10 | 11–8 | 14-11 | 18-1 | 8-10 | 11–8 | 14-11 | 18-0 |
Southern Pine #1 | 8-6 | 11–3 | 13-1 | 15-7 | 8-1 | 10-3 | 12-0 | 14-3 |
Southern Pine #2 | 7-7 | 9-8 | 11–5 | 13-6 | 7-0 | 8-10 | 10-5 | 12-4 |
Southern Pine #3 | 5-9 | 7-3 | 8-10 | 10-5 | 5-3 | 6-8 | 8-1 | 9-6 |
43. Change footnote "b" in Table R502.3.3(1) to read:
b. Spans are based on minimum design properties for No. 2 Grade lumber of Douglas fir-larch, hem-fir, and spruce-pine-fir for repetitive (three or more) members. No. 1 or better grade lumber shall be used for southern pine.
44. Change footnote "a" in Table R502.3.3(2) to read:
a. Spans are based on minimum design properties for No. 2 Grade lumber of Douglas fir-larch, hem-fir, and spruce-pine-fir for repetitive (three or more) members. No. 1 or better grade lumber shall be used for southern pine.
45. Change Section R502.5 to read:
R502.5 Allowable girder and header spans. The allowable spans of girders and headers fabricated of dimension lumber shall not exceed the values set forth in Tables R502.5(1) through R502.5(3).
46. Change the title and footnote "b" of Table R502.5(1) to read:
Table R502.5(1)
Girder Spansa,b and Header Spansa,b for Exterior Bearing Walls
(Maximum Spans for Douglas fir-larch, hem-fir, southern pine, and spruce-pine-firb and required number of jack studs)
b. Spans are based on minimum design properties for No. 2 Grade lumber of Douglas fir-larch, hem-fir, and spruce-pine-fir. No. 1 or better grade lumber shall be used for southern pine.
47. Change the title and footnote "b" of Table R502.5(2) to read:
Table R502.5(2)
Girder Spansa,b and Header Spansa,b for Interior Bearing Walls
(Maximum Spans for Douglas fir-larch, hem-fir, southern pine, and spruce-pine-firb and required number of jack studs)
b. Spans are based on minimum design properties for No. 2 Grade lumber of Douglas fir-larch, hem-fir, and spruce-pine-fir. No. 1 or better grade lumber shall be used for southern pine.
38. Change Section R502.5 and add 48. Add ] Table R502.5(3) to read:
[ R502.5 Allowable girder and header spans. The allowable spans of girders and headers fabricated of dimension lumber shall not exceed the values set forth in Tables R502.5(1) through R502.5(3). ]
Table R502.5(3) Girder and Header Spans [ a ] for Porches [ a, ] b [ ,c ] (Maximum span for southern pine) |
[ Header ] Supporting | [ Header ] Size | Porch Width (ft) |
8 | 14 |
Roof | 2-2x4 | 6'-11" | 5'-3" |
2-2x6 | 9'-11" | 7'-6" |
2-2x8 | 12'-10" | 9'-8" |
2-2x10 | 16'-8" | 12'-7" |
2-2x12 | 19'-6" | 14'-9" |
Floor | 2-2x4 | 5'-1" | 3'-10" |
2-2x6 | 7'-4" | 5'-6" |
2-2x8 | 9'-5" | 7'-1" |
2-2x10 | 12'-2" | 9'-3" |
2-2x12 | 14'-4" | 10'-10" |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. [ a. Spans are given in feet and inches. a. b. ] Tabulated values based on 30 psf ground snow load, L/240 deflection and #2 grade lumber. [ b. c. ] The values of this table shall be equivalent to a roof live load of 20 psf. |
44. [ 39. 49. ] Change Section R506.2.1 to read:
R506.2.1 Fill. Fill material shall be free of vegetation and foreign material and shall be natural nonorganic material that is not susceptible to swelling when exposed to moisture. The fill shall be compacted to assure uniform support of the slab, and except where approved, the fill depth shall not exceed 24 inches (610 mm) for clean sand or gravel and 8 inches (203 mm) for earth.
Exception: Material other than natural material may be used as fill material when accompanied by a certification from an RDP and approved by the building official.
45. [ 40. 50. ] Change Section R506.2.2 to read:
R506.2.2 Base. A 4-inch-thick (102 mm) base course consisting of clean graded sand, gravel or crushed stone passing a 2-inch (51 mm) sieve shall be placed on the prepared subgrade when the slab is below grade.
Exception: A base course is not required when the concrete slab is installed on well drained or sand-gravel mixture soils classified as Group I according to the United Soil Classification System in accordance with Table R405.1. Material other than natural material may be used as base course material when accompanied by a certification from an RDP and approved by the building official.
[ 51. Change Section R507.1 to read:
R507.1 Decks. Wood-framed decks shall be in accordance with this section or Section R301 for materials and conditions not prescribed in this section. Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads. Such attachment shall not be accomplished by the use of toenails or nails subject to withdrawal. Where positive connection to the primary building structure cannot be verified during inspection, decks shall be self-supporting. For decks with cantilevered framing members, connections to exterior walls or other framing members shall be designed and constructed to resist uplift resulting from the full live load specified in Table R301.5 acting on the cantilevered portion of the deck.
52. Add Sections R507.4 through R507.8 to read:
R507.4 Decking. Maximum allowable spacing for wood joists supporting decking shall be in accordance with Table R507.4. Wood decking shall be attached to each supporting member with a minimum of two 8d nails or two #8 wood screws.
Table R507.4 Maximum Joist Spacing (inches) |
Material Type and Nominal Size | Maximum Joist Spacing |
Perpendicular to Joist | Diagonal to Joista |
5/4-inch thick wood | 16 | 12 |
2-inch thick wood | 24 | 16 |
Wood/plastic composite | per R507.3 | per R507.3 |
For SI: 1 inch = 25.4 mm a. Maximum angle of 45 degrees from perpendicular for wood deck boards. |
R507.5 Deck joists. Maximum allowable spans for wood deck joists, as shown in Figure R507.5, shall be in accordance with Table R507.5. Deck joist shall be permitted to cantilever a maximum of one-fourth of the actual, adjacent joist span.
Table R507.5 Deck Joist Spansa and Cantileversa for Common Lumber Species |
Speciesa | Size | Allowable Joist Spanc | Allowable Cantileverd,e |
Spacing of deck joists (in.) | Spacing of deck joists (in.) |
12 | 16 | 24 | 12 | 16 | 24 |
Southern pine | 2 x 6 | 9-11 | 9-0 | 7-7 | 1–3 | 1–4 | 1–6 |
2 x 8 | 13-1 | 11–10 | 9-8 | 2-1 | 2-3 | 2-5 |
2 x 10 | 16-2 | 14-0 | 11–5 | 3-4 | 3-6 | 2-10 |
2 x 12 | 18-0 | 16-6 | 13-6 | 4-6 | 4-2 | 3-4 |
Douglas fir-larchf, hem-firf, spruce-pine-firf | 2 x 6 | 9-6 | 8-4 | 6-10 | 1–2 | 1–3 | 1–5 |
2 x 8 | 12-6 | 11–1 | 9-1 | 1–11 | 2-1 | 2-3 |
2 x 10 | 15-8 | 13–7 | 11–1 | 3-1 | 3-5 | 2-9 |
2 x 12 | 18-0 | 15–9 | 12-10 | 4-6 | 3-11 | 3-3 |
Redwood, western cedars, ponderosa pineg, red pineg | 2 x 6 | 8-10 | 8-0 | 6-10 | 1–0 | 1–1 | 1–2 |
2 x 8 | 11–8 | 10–7 | 8-8 | 1–8 | 1–10 | 2-0 |
2 x 10 | 14-11 | 13–0 | 10-7 | 2-8 | 2-10 | 2-8 |
2 x 12 | 17-5 | 15-1 | 12-4 | 3-10 | 3-9 | 3-1 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Spans and cantilevers are given in feet and inches. b. No. 2 grade with wet service factor. c. Ground snow load, live load = 40 psf, dead load = 10 psf, L/Δ = 360. d. Ground snow load, live load = 40 psf, dead load = 10 psf, L/Δ = 360 at main span, L/Δ = 180 at cantilever with a 220 pound point load applied to end. e. Maximum allowable cantilever shall not exceed one-fourth of the actual joist span. f. Includes incising factor. g. Northern species with no incising factor. |
R507.5.1 Lateral restraint at supports. Joist ends and bearing locations shall be provided with lateral restraint to prevent rotation. Where lateral restraint is provided by joist hangers or blocking between joists, their depth shall equal not less than 60% of the joist depth. Where lateral restraint is provided by rim joists, they shall be secured to the end of each joist with a minimum of (3)10d (3-inch x 0.128-inch) nails or (3)#10x3 inch (76 mm) long wood screws.
R507.6 Deck beams. Maximum allowable spans for wood deck beams, as shown in Figure R507.6, shall be in accordance with Table R507.6. Beam plies shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches (406 mm) on center along each edge. Beams shall be permitted to cantilever at each end up to one-fourth of the beam span. Splices of multi-span beams shall be located at interior post locations.
Table R507.6 Deck Beam Spana Lengthsb,c |
Speciesd | Sizee | Deck Joist Span (feet) Less Than or Equal To: |
6 | 8 | 10 | 12 | 14 | 16 | 18 |
Southern pine | 2-2x6 | 6-11 | 5-11 | 5-4 | 4-10 | 4-6 | 4-3 | 4-0 |
2-2x8 | 8-9 | 7-7 | 6-9 | 6-2 | 5-9 | 5-4 | 5-0 |
2-2x10 | 10-4 | 9-0 | 8-0 | 7-4 | 6-9 | 6-4 | 6-0 |
2-2x12 | 12-2 | 10-7 | 9-5 | 8-7 | 8-0 | 7-6 | 7-0 |
3-2x6 | 8-2 | 7-5 | 6-8 | 6-1 | 5-8 | 5-3 | 5-0 |
3-2x8 | 10-10 | 9-6 | 8-6 | 7-9 | 7-2 | 6-8 | 6-4 |
3-2x10 | 13-0 | 11–3 | 10-0 | 9-2 | 8-6 | 7-11 | 7-6 |
3-2x12 | 15-3 | 13-3 | 11–10 | 10-9 | 10-0 | 9-4 | 8-10 |
Douglas fir-larchf, hem-firf, spruce-pine-firf, redwood, western cedars, ponderosa pineg, red pineg | 3x6 or 2-2x6 | 5-5 | 4-8 | 4-2 | 3-10 | 3-6 | 3-1 | 2-9 |
3x8 or 2-2x8 | 6-10 | 5-11 | 5-4 | 4-10 | 4-6 | 4-1 | 3-8 |
3x10 or 2-2x10 | 8-4 | 7-3 | 6-6 | 5-11 | 5-6 | 5-1 | 4-8 |
3x12 or 2-2x12 | 9-8 | 8-5 | 7-6 | 6-10 | 6-4 | 5-11 | 5-7 |
4x6 | 6-5 | 5-6 | 4-11 | 4-6 | 4-2 | 3-11 | 3-8 |
4x8 | 8-5 | 7-3 | 6-6 | 5-11 | 5-6 | 5-2 | 4-10 |
4x10 | 9-11 | 8-7 | 7-8 | 7-0 | 6-6 | 6-1 | 5-8 |
4x12 | 11–5 | 9-11 | 8-10 | 8-1 | 7-6 | 7-0 | 6-7 |
3-2x6 | 7-4 | 6-8 | 6-0 | 5-6 | 5-1 | 4-9 | 4-6 |
3-2x8 | 9-8 | 8-6 | 7-7 | 6-11 | 6-5 | 6-0 | 5-8 |
3-2x10 | 12-0 | 10-5 | 9-4 | 8-6 | 7-10 | 7-4 | 6-11 |
3-2x12 | 13-11 | 12-1 | 10-9 | 9-10 | 9-1 | 8-6 | 8-1 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Spans are given in feet and inches. b. Ground snow load, live load = 40 psf, dead load = 10 psf, L/Δ = 360 at main span, L/Δ = 180 at cantilever with a 220 pound point load applied at the end. c. Beams supporting deck joists from one side only. d. No. 2 grade, wet service factor. e. Beam depth shall be greater than or equal to depth of joists with a flush beam condition. f. Includes incising factor. g. Northern species with no incising factor. |
R507.7 Deck joist and deck beam bearing. The ends of each joist and beam shall have not less than 1.5 inches (38 mm) of bearing on wood or metal and not less than three inches (76 mm) on concrete or masonry for the entire width of the beam. Joist framing into the side of a ledger board or beam shall be supported by approved joist hangers. Joists bearing on a beam shall be attached to the beam to resist lateral displacement.
R507.7.1 Deck beam to deck post. Deck beams shall be attached to deck posts in accordance with Figure R507.7.1 or by other equivalent means capable to resist lateral displacement. Manufactured post-to-beam connectors shall be sized for the post and beam sizes. All bolts shall have washers under the head and nut.
Exception: Where deck beams bear directly on footings in accordance with Section R507.8.1.
R507.8 Deck posts. For single level wood-framed decks with beams sized in accordance with Table R507.6, deck post size shall be in accordance with Table R507.8.
Table R507.8 Deck Post Heighta (feet) |
Deck Post Size | Maximum Heighta |
4x4 | 8 |
4x6 | 8 |
6x6 | 14 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Measured to the underside of the beam. |
R507.8.1 Deck post to deck footing. Posts shall bear on footings in accordance with Section R403 and Figure R507.8.1. Posts shall be restrained to prevent lateral displacement at the footing. Lateral restraint shall be provided by manufactured connectors installed in accordance with the manufacturers' installation instructions or by a minimum post embedment of 12 inches (304.8 mm) in surrounding soils or concrete piers.
Figure R507.8.1
Typical Deck Posts to Deck Footings ]
46. Modify Table R602.3(1) to change and add items as shown:
7 | Built-up studs, face nail | 10d (3"x0.128") | 24" o.c. |
7a | Abutting studs at intersecting wall corners, face nail | 16d (3½"x0.135") | 12" o.c. |
26a | Rim joist or blocking to sill plate, toe nail | 8d (2½"x0.113") | 6" o.c. |
[ 53. Change Section R602.3.1 to read:
R602.3.1 Stud size, height, and spacing. The size, height, and spacing of studs shall be in accordance with Table R602.3(5).
Exceptions:
1. Utility grade studs shall not be spaced more than 16 inches (406 mm) on center, shall not support more than a roof and ceiling, and shall not exceed eight feet (2438 mm) in height for exterior walls and load-bearing walls or 10 feet (3048 mm) for interior nonload-bearing walls.
2. Where snow loads are less than or equal to 25 pounds per square foot (1.198 kPa), and the ultimate design wind speed is less than or equal to 130 mph (58.11 m/s), 2-inch by 6-inch (38 mm by 140 mm) studs supporting a roof load with not more than six feet (1829 mm) of tributary length shall have a maximum height of 18 feet (5486 mm) where spaced at 16 inches (406 mm) on center, or 20 feet (6096 mm) where spaced at 12 inches (305 mm) on center. Studs shall be minimum No. 2 grade lumber.
54. Delete Table R602.3.1. ]
47. Add Section R602.3.5 to read:
R602.3.5 Braced wall panel uplift load path. Braced wall panels located at exterior walls that support roof rafters or trusses (including stories below top story) shall have the framing members connected in accordance with one of the following:
1. Fastening in accordance with Table R602.3(1) where:
1.1. The basic wind speed does not exceed 90 mph (40 m/s), the wind exposure category is B, the roof pitch is 5:12 or greater, and the roof span is 32 feet (9754 mm) or less, or
1.2. The net uplift value at the top of a wall does not exceed 100 plf (146 N/mm). The net uplift value shall be determined in accordance with Section R802.11 and shall be permitted to be reduced by 60 plf (57 N/mm) for each full wall above.
2. Where the net uplift value at the top of a wall exceeds 100 plf (146 N/mm), installing approved uplift framing connectors to provide a continuous load path from the top of the wall to the foundation or to a point where the uplift force is 100 plf (146 N/mm) or less. The net uplift value shall be as determined in Item 1.2 above.
3. Wall sheathing and fasteners designed in accordance with accepted engineering practice to resist combined uplift and shear forces.
[ 41. 55. ] Change Figure R602.3(2) to read:
[ 56. Change the column entries under the heading "Wood Species" in Table R602.7.1 to read:
| Spruce-Pine-Fir Hem-Fir Douglas-Fir or No. 1 Grade Southern Pine |
42. 57. ] Add Section R602.7.4 to read:
R602.7.4 Supports for headers. Headers shall be supported on each end with one or more jack studs in accordance with Table R505.5(1) or Table R502.5(2). A king stud shall be adjacent to the jack stud on each end of the header and nailed at each end of the header with 4-12d nails.
48. Change Section R602.9 to read:
R602.9 Cripple walls. Foundation cripple walls shall be framed of studs not smaller than the studding above. When exceeding four feet (1219 mm) in height, such walls shall be framed of studs having the size required for an additional story.
Cripple walls with a stud height less than 14 inches (356 mm) shall be continuously sheathed on one side with wood structural panels fastened to both the top and bottom plates in accordance with Table R602.3(1), or the cripple walls shall be constructed of solid blocking. Cripple walls shall be supported on continuous foundations.
49. Replace Section R602.10, including all subsections, with the following:
R602.10 Wall bracing. Buildings shall be braced in accordance with this section or, when applicable, Section R602.12. Where a building, or portion thereof, does not comply with one or more of the bracing requirements in this section, those portions shall be designed and constructed in accordance with Section R301.1.
The building official may require the permit applicant to identify and locate on the construction documents braced wall lines and braced wall panels as described herein.
R602.10.1 Braced wall lines. For the purpose of determining the amount and location of bracing required in each story level of a building, braced wall lines shall be designated as straight lines in the building plan placed in accordance with this section.
R602.10.1.1 Length of a braced wall line. The length of a braced wall line shall be the distance between its ends. The end of a braced wall line shall be the intersection with a perpendicular braced wall line, an angled braced wall line as permitted in Section R602.10.1.4 or an exterior wall as shown in Figure R602.10.1.1.
R602.10.1.2 Offsets along a braced wall line. All exterior walls parallel to a braced wall line shall be permitted to offset up to four feet (1219 mm) from the designated braced wall line location as shown Figure R602.10.1.1. Interior walls used as bracing shall be permitted to offset up to four feet (1219 mm) from a braced wall line through the interior of the building as shown in Figure R602.10.1.1.
R602.10.1.3 Spacing of braced wall lines. There shall be a minimum of two braced wall lines in both the longitudinal and transverse direction as shown in Figure R602.10.1.1. Intermediate braced wall lines through the interior of the building shall be permitted. The spacing between parallel braced wall lines shall be in accordance with Table R602.10.1.3.
Table R602.10.1.3 Braced Wall Line Spacing |
APPLICATION | CONDITION | BUILDING TYPE | BRACED WALL LINE SPACING CRITERIA |
Maximum Spacing | Exception to Maximum Spacing |
Wind bracing | 85 mph to <110 mph | Detached, townhouse | 60 feet | None |
Seismic bracing | SDC A - C | Detached | Use wind bracing |
SDC A – B | Townhouse | Use wind bracing |
SDC C | Townhouse | 35 feet | Up to 50 feet when length of required bracing per Table R602.10.3(3) is adjusted in accordance with Table R602.10.3(4) |
For SI: 1 foot=304.8 mm |
R602.10.1.4 Angled walls. Any portion of a wall along a braced wall line shall be permitted to angle out of plane for a maximum diagonal length of eight feet (2438 mm). Where the angled wall occurs at a corner, the length of the braced wall line shall be measured from the projected corner as shown in Figure R602.10.1.4. Where the diagonal length is greater than eight feet (2438 mm), it shall be considered a separate braced wall line and shall be braced in accordance with Section R602.10.1.
R602.10.2 Braced wall panels. Braced wall panels shall be full-height sections of wall that shall have no vertical or horizontal offsets. Braced wall panels shall be constructed and placed along a braced wall line in accordance with this section and the bracing methods specified in Section R602.10.4.
R602.10.2.1 Braced wall panel uplift load path. The bracing lengths in Table R602.10.3(1) apply only when uplift loads are resisted per Section R602.3.5.
R602.10.2.2 Locations of braced wall panels. A braced wall panel shall begin within 10 feet (3810 mm) from each end of a braced wall line as determined in accordance with Section R602.10.1.1. The distance between adjacent edges of braced wall panels along a braced wall line shall be no greater than 20 feet (6096 mm) as shown in Figure R602.10.2.2.
R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4877 mm) or less shall have a minimum of two braced wall panels of any length or one braced wall panel equal to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet (4877 mm) shall have a minimum of two braced wall panels.
R602.10.3 Required length of bracing. The required length of bracing along each braced wall line shall be determined as follows.
1. All buildings in Seismic Design Categories A and B shall use Table R602.10.3(1) and the applicable adjustment factors in Table R602.10.3(2).
2. Detached buildings in Seismic Design Category C shall use Table R602.10.3(1) and the applicable adjustment factors in Table R602.10.3(2).
3. Townhouses in Seismic Design Category C shall use the greater value determined from Table R602.10.3(1) or R602.10.3(3) and the applicable adjustment factors in Table R602.10.3(2) or R602.10.3(4) respectively.
Only braced wall panels parallel to the braced wall line within the four foot (1219 mm) offset permitted by Section R602.10.1.2 shall contribute towards the required length of bracing of that braced wall line. If a braced wall panel is located along an angled wall and meets the minimum length requirements of Tables R602.10.5 or R602.10.5.2, it shall be permitted to contribute its projected length towards the minimum required length of bracing for the braced wall line as shown in Figure R602.10.1.4. If a braced wall panel is located along an angled wall at the end of a braced wall line, it shall contribute its projected length for only one of the braced wall lines at the projected corner.
Table R602.10.3(1) Bracing Requirements Based on Wind Speed |
EXPOSURE CATEGORY B 30 FT MEAN ROOF HEIGHT 10 FT EAVE TO RIDGE HEIGHT 10 FT WALL HEIGHT 2 BRACED WALL LINES | MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS REQUIRED ALONG EACH BRACED WALL LINEa |
Basic Wind Speed (mph) | Story Location | Braced Wall Line Spacing (feet) | Method LIBb | Method GB | Methods DWB, WSP, SFB, PBS, PCP, HPS, CS-SFBc | Methods CS-WSP, CS-G, CS-PF |
≤ 85 | | 10 | 3.5 | 3.5 | 2.0 | 1.5 |
20 | 6.0 | 6.0 | 3.5 | 3.0 |
30 | 8.5 | 8.5 | 5.0 | 4.5 |
40 | 11.5 | 11.5 | 6.5 | 5.5 |
50 | 14.0 | 14.0 | 8.0 | 7.0 |
60 | 16.5 | 16.5 | 9.5 | 8.0 |
| 10 | 6.5 | 6.5 | 3.5 | 3.0 |
20 | 11.5 | 11.5 | 6.5 | 5.5 |
30 | 16.5 | 16.5 | 9.5 | 8.0 |
40 | 21.5 | 21.5 | 12.5 | 10.5 |
50 | 26.5 | 26.5 | 15.0 | 13.0 |
60 | 31.5 | 31.5 | 18.0 | 15.5 |
| 10 | NP | 9.0 | 5.5 | 4.5 |
20 | NP | 17.0 | 10.0 | 8.5 |
30 | NP | 24.5 | 14.0 | 12.0 |
40 | NP | 32.0 | 18.0 | 15.5 |
50 | NP | 39.0 | 22.5 | 19.0 |
60 | NP | 46.5 | 26.5 | 22.5 |
≤ 90 | | 10 | 3.5 | 3.5 | 2.0 | 2.0 |
20 | 7.0 | 7.0 | 4.0 | 3.5 |
30 | 9.5 | 9.5 | 5.5 | 5.0 |
40 | 12.5 | 12.5 | 7.5 | 6.0 |
50 | 15.5 | 15.5 | 9.0 | 7.5 |
60 | 18.5 | 18.5 | 10.5 | 9.0 |
| 10 | 7.0 | 7.0 | 4.0 | 3.5 |
20 | 13.0 | 13.0 | 7.5 | 6.5 |
30 | 18.5 | 18.5 | 10.5 | 9.0 |
40 | 24.0 | 24.0 | 14.0 | 12.0 |
50 | 29.5 | 29.5 | 17.0 | 14.5 |
60 | 35.0 | 35.0 | 20.0 | 17.0 |
| 10 | NP | 10.5 | 6.0 | 5.0 |
20 | NP | 19.0 | 11.0 | 9.5 |
30 | NP | 27.5 | 15.5 | 13.5 |
40 | NP | 35.5 | 20.5 | 17.5 |
50 | NP | 44.0 | 25.0 | 21.5 |
60 | NP | 52.0 | 30.0 | 25.5 |
≤ 100 | | 10 | 4.5 | 4.5 | 2.5 | 2.5 |
20 | 8.5 | 8.5 | 5.0 | 4.0 |
30 | 12.0 | 12.0 | 7.0 | 6.0 |
40 | 15.5 | 15.5 | 9.0 | 7.5 |
50 | 19.0 | 19.0 | 11.0 | 9.5 |
60 | 22.5 | 22.5 | 13.0 | 11.0 |
| 10 | 8.5 | 8.5 | 5.0 | 4.5 |
20 | 16.0 | 16.0 | 9.0 | 8.0 |
30 | 23.0 | 23.0 | 13.0 | 11.0 |
40 | 29.5 | 29.5 | 17.0 | 14.5 |
50 | 36.5 | 36.5 | 21.0 | 18.0 |
60 | 43.5 | 43.5 | 25.0 | 21.0 |
| 10 | NP | 12.5 | 7.5 | 6.0 |
20 | NP | 23.5 | 13.5 | 11.5 |
30 | NP | 34.0 | 19.5 | 16.5 |
40 | NP | 44.0 | 25.0 | 21.5 |
50 | NP | 54.0 | 31.0 | 26.5 |
60 | NP | 64.0 | 36.5 | 31.0 |
< 110 | | 10 | 5.5 | 5.5 | 3.0 | 3.0 |
20 | 10.0 | 10.0 | 6.0 | 5.0 |
30 | 14.5 | 14.5 | 8.5 | 7.0 |
40 | 18.5 | 18.5 | 11.0 | 9.0 |
50 | 23.0 | 23.0 | 13.0 | 11.5 |
60 | 27.5 | 27.5 | 15.5 | 13.5 |
| 10 | 10.5 | 10.5 | 6.0 | 5.0 |
20 | 19.0 | 19.0 | 11.0 | 9.5 |
30 | 27.5 | 27.5 | 16.0 | 13.5 |
40 | 36.0 | 36.0 | 20.5 | 17.5 |
50 | 44.0 | 44.0 | 25.5 | 21.5 |
60 | 52.5 | 52.5 | 30.0 | 25.5 |
| 10 | 0 | 15.5 | 9.0 | 7.5 |
20 | NP | 28.5 | 16.5 | 14.0 |
30 | NP | 41.0 | 23.5 | 20.0 |
40 | NP | 53.0 | 30.5 | 26.0 |
50 | NP | 65.5 | 37.5 | 32.0 |
60 | NP | 77.5 | 44.5 | 37.5 |
For SI: 1 inch=25.4 mm, 1 foot=305 mm. aLinear interpolation shall be permitted. bMethod LIB shall have gypsum board fastened to at least one side with nails or screws per Table R602.3(1) for exterior sheathing or Table R702.3.5 for interior gypsum board. Spacing of fasteners at panel edges shall not exceed eight inches (203 mm). cMethod CS-SFB does not apply where the wind speed is greater than 100 mph. |
Table R602.10.3(2) Wind Adjustment Factors to the Required Length of Wall Bracing |
ADJUSTMENT BASED ON | STORY/ SUPPORTING | CONDITION | ADJUSTMENT FACTORa,b (multiply length from Table R602.10.3(1) by this factor) | APPLICABLE METHODS |
Exposure category | One story structure | B | 1.00 | All methods |
C | 1.20 |
D | 1.50 |
Two-story structure | B | 1.00 |
C | 1.30 |
D | 1.60 |
Three-story structure | B | 1.00 |
C | 1.40 |
D | 1.70 |
Roof eave-to-ridge height | Roof only | ≤5 ft | 0.70 |
10 ft | 1.00 |
15 ft | 1.30 |
20 ft | 1.60 |
Roof + 1 floor | ≤5 ft | 0.85 |
10 ft | 1.00 |
15 ft | 1.15 |
20 ft | 1.30 |
Roof + 2 floors | ≤5 ft | 0.90 |
10 ft | 1.00 |
15 ft | 1.10 |
20 ft | Not permitted |
Wall height adjustment | Any story | 8 ft | 0.90 |
9 ft | 0.95 |
10 ft | 1.00 |
11 ft | 1.05 |
12 ft | 1.10 |
Number of braced wall lines (per plan direction)C | Any story | 2 | 1.00 |
3 | 1.30 |
4 | 1.45 |
≥5 | 1.60 |
Additional 800 lb hold-down device | Top story only | Fastened to the end studs of each braced wall panel and to the foundation or framing below | 0.80 | DWB, WSP, SFB, PBS, PCP, HPS |
Interior gypsum board finish (or equivalent) | Any story | Omitted from inside face of braced wall panels | 1.40 | DWB, WSP, SFB,PBS, PCP, HPS, CS-WSP, CS‑G, CS-SFB |
Gypsum board fastening | Any story | 4 in. o.c. at panel edges, including top and bottom plates, and all horizontal joints blocked | 0.7 | GB |
For SI: 1 foot=305 mm, 1 lb=4.48 N. aLinear interpolation shall be permitted. bThe total adjustment factor is the product of all applicable adjustment factors. cThe adjustment factor is permitted to be 1.0 when determining bracing amounts of intermediate braced wall lines provided the bracing amounts on adjacent braced wall lines are based on a spacing and number that neglects the intermediate braced wall line. |
Table R602.10.3(3) Bracing Requirements Based on Seismic Design Category |
SOIL CLASS Db WALL HEIGHT = 10 FT 10 PSF FLOOR DEAD LOAD 15 PSF ROOF/CEILING DEAD LOAD BRACED WALL LINE SPACING ≤ 25 FT | MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS REQUIRED ALONG EACH BRACED WALL LINEa |
Seismic Design Category | Story Location | Braced Wall Line Length (ft) | Method LIBc | Method GB | Methods DWB, SFB, PBS, PCP, HPS, CS-SFB | Method WSP | Methods CS-WSP, CS‑G |
C (townhouses only) | | 10 | 2.5 | 2.5 | 2.5 | 1.6 | 1.4 |
20 | 5.0 | 5.0 | 5.0 | 3.2 | 2.7 |
30 | 7.5 | 7.5 | 7.5 | 4.8 | 4.1 |
40 | 10.0 | 10.0 | 10.0 | 6.4 | 5.4 |
50 | 12.5 | 12.5 | 12.5 | 8.0 | 6.8 |
| 10 | NP | 4.5 | 4.5 | 3.0 | 2.6 |
20 | NP | 9.0 | 9.0 | 6.0 | 5.1 |
30 | NP | 13.5 | 13.5 | 9.0 | 7.7 |
40 | NP | 18.0 | 18.0 | 12.0 | 10.2 |
50 | NP | 22.5 | 22.5 | 15.0 | 12.8 |
| 10 | NP | 6.0 | 6.0 | 4.5 | 3.8 |
20 | NP | 12.0 | 12.0 | 9.0 | 7.7 |
30 | NP | 18.0 | 18.0 | 13.5 | 11.5 |
40 | NP | 24.0 | 24.0 | 18.0 | 15.3 |
50 | NP | 30.0 | 30.0 | 22.5 | 19.1 |
For SI: 1 foot=305 mm aLinear interpolation shall be permitted. bWall bracing lengths are based on a soil site class "D." Interpolation of bracing length between the Sds values associated with the Seismic Design Categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.5 of the International Building Code. cMethod LIB shall have gypsum board fastened to at least one side with nails or screws per Table R602.3(1) for exterior sheathing or Table R702.3.5 for interior gypsum board. Spacing of fasteners at panel edges shall not exceed eight inches (203 mm). |
Table R602.10.3(4) Seismic Adjustment Factors to the Required Length of Wall Bracing |
ADJUSTMENT BASED ON: | STORY/SUPPORTING | CONDITION | ADJUSTMENT FACTORa,b (multiply length from Table R602.10.3(3) by this factor) | |